PSM02 Slim Multi-Sensor

This describes the Z-Wave device PSM02, manufactured by Philio Technology Corp with the thing type UID of philio_psm02_00_000.

Slim Multi-Sensor

Channels

The following table summarises the channels available for the PSM02 Slim Multi-Sensor.

Channel Channel Id Channel Type UID Category Item Type
Motion Sensor alarm_motion alarm_motion Door Switch
Tamper Alarm alarm_tamper alarm_tamper   Switch
Door/Window Sensor sensor_door sensor_door Door Contact
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the PSM02 Slim Multi-Sensor. Detailed information on each parameter can be found below.

Parameter Description
2: Basic Set Level -1 -> 0xFF(-1) turns on the light. 1 - 100 -> For dimmers 1 to 100 means the light streng…
3: PIR Sensitivity parameter to set the Sensitivity for the PIR (Passiv Infrared Sensor) 0 -> 0 means disable…
4: Light Threshold Setting the illumination threshold to turn on the light. When the event triggered and the …
5: Operation Mode Bit 0: 1 means security mode; 0 means home automation mode. Bit 1: 1 means enable test mod…
6: Multi-Sensor Function Switch  
8: PIR Re-Detect Interval Time In the security mode, after the PIR motion detected, setting the re-detect time 3 8 sec - …
9: Turn Off Light Time After turn on the light, setting the delay time to turn off the light when the PIR motion …
10: Auto Report Battery Time interval time for auto report the battery level 1 30 min - 127 30 min -> 30 minutes per ti…
11: Auto Report Door/Window State Time interval time for auto report the door/window state 1 30 min - 127 30 min -> 30 minutes pe…
12: Auto Report Illumination Time interval time for auto report the illumination state 1 30 min - 127 30 min -> 30 minutes p…
13: Auto Report Temperature Time Interval time for auto report the temperature state 1 30 min - 127 30 min -> 30 minutes pe…
1: Reports  
2: Light Control  

2: Basic Set Level

-1 -> 0xFF(-1) turns on the light. 1 - 100 -> For dimmers 1 to 100 means the light strength

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range -1 to 100
Default Value -1

3: PIR Sensitivity

parameter to set the Sensitivity for the PIR (Passiv Infrared Sensor) 0 -> 0 means disable the PIR motion; 1 - 99 -> 1 means the lowest sensitivity, 99 means the highest sensitivity

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 99
Default Value 70

4: Light Threshold

Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light 0 -> 0 means turn off illumination detected function And never turn on the

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 100
Default Value 100

5: Operation Mode

Bit 0: 1 means security mode; 0 means home automation mode. Bit 1: 1 means enable test mode; 0 means disable test mode. Notice: Bit0 and Bit1 will effect when the DIP Switch setting to program mode. If Bit1 is enabled, the Bit0 is useless. Bit 2: Disable

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 0 to 127
Default Value 0

6: Multi-Sensor Function Switch

Overview

Bit 0: Disable magnetic integrate illumination.

Bit 1: Disable PIR integrate Illumination.

Bit 2: Disable magnetic integrate PIR (Default is Disable)

Bit 3: When Bit2 is 0 (Enable), the device is install in the same room with the light? 0:

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 0 to 127
Default Value 4

8: PIR Re-Detect Interval Time

In the security mode, after the PIR motion detected, setting the re-detect time 3 8 sec - 127 8 sec -> 8 seconds per tick, and minimum time is 24 seconds, default tick is 3 (24 seconds).

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 3 to 127
Default Value 3

9: Turn Off Light Time

After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected 4 8 sec - 127 8 sec -> 8 seconds per tick, and minimum time is 32 seconds, default tick is 4 (32 seconds)

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 4 to 127
Default Value 4

10: Auto Report Battery Time

interval time for auto report the battery level 1 30 min - 127 30 min -> 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours)

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 1 to 127
Default Value 12

11: Auto Report Door/Window State Time

interval time for auto report the door/window state 1 30 min - 127 30 min -> 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours)

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 1 to 127
Default Value 12

12: Auto Report Illumination Time

interval time for auto report the illumination state 1 30 min - 127 30 min -> 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours)

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 1 to 127
Default Value 12

13: Auto Report Temperature Time

Interval time for auto report the temperature state 1 30 min - 127 30 min -> 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours)

Property Value
Configuration ID config_13_1
Data Type INTEGER
Range 1 to 127
Default Value 12

1: Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Light Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to