Channels

The following table summarises the channels available for the PSP05 Motion Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the PSP05 Motion Sensor. Detailed information on each parameter can be found below.

Parameter Description
3: PIR Sensitivity Adjust the PIR Sensitivity
7: Motion OFF Reporting Sends notification when motion has completed.
7: Notification Type Method used to send notifications on motion
7: Send Multi CC in auto report Send Multi CC in auto report
7: Send Battery Report when Triggered Whether or not a battery status report should be sent when triggered
8: Re-detection interval Multiples of 8 seconds to wait before re-detection
9: Turn off light time Time to wait after lighting has been turned on before turning off again
10: Batery level reporting interval How frequently battery status should be reported
20: Tick Interval Interval time for sending reports

3: PIR Sensitivity

Adjust the PIR Sensitivity

Overview

This setting sets the sensitivity of the PIR (motion) sensor. A setting of 0 (zero) will disable the sensor, with 99 being the highest level of sensitivity. The default sensitivity setting is 80.

The higher the sensitivity, the greater the range of detection (things farther away will trigger the sensor). However, this may also result in things that are nearer triggering the sensor too frequently.

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 99
Default Value 80

7: Motion OFF Reporting

Sends notification when motion has completed.

Overview

Sends notification when motion has completed.

Property Value      
Configuration ID config_7_1_00000010      
Data Type INTEGER   Default Value 0
Options Don't Send Report (0)      
  Send Report (1)      

7: Notification Type

Method used to send notifications on motion

Overview

Indicates method used to send notifications in the event of motion being triggered. Either Binary Sensor or Notification

Property Value      
Configuration ID config_7_1_00001000      
Data Type INTEGER   Default Value 0
Options Report Notification (0)      
  Binary Sensor (1)      

7: Send Multi CC in auto report

Send Multi CC in auto report

Overview

Investigation required to determine purpose of this.

Property Value      
Configuration ID config_7_1_00010000      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

7: Send Battery Report when Triggered

Whether or not a battery status report should be sent when triggered

Property Value      
Configuration ID config_7_1_00100000      
Data Type INTEGER   Default Value 0
Options Enable (0)      
  Disable (1)      

8: Re-detection interval

Multiples of 8 seconds to wait before re-detection

Overview

By default, the sensor will wait 24 seconds (3 x 8) after detecting motion before it will send a further detection report. This value can be increased to a maximum of 127 (which is 127 * 8), meaning the re-detection interval will be 1,016 seconds (~17 minutes). The minimum value is 1 (1 * 8), meaning a re-detection interval of 8 seconds.

The default is a value of 3, meaning a re-detection interval of 24 seconds.

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 1 to 127
Default Value 3

9: Turn off light time

Time to wait after lighting has been turned on before turning off again

Overview

Number of seconds (in multiples of 8) to wait before turning off lights that were turned on as a result of motion occurring. A default value of 4 means (4 x 8) 32 seconds later, lights will be turned off.

This setting should only be used when you are using association groups to control lighting events. If you are controlling on/off events as a result of motion through independent rules, this setting is irrelevant.

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 127
Default Value 4

10: Batery level reporting interval

How frequently battery status should be reported

Overview

The frequency (in multiples of ‘Tick Time’) that the device should send battery status reports. If set to 0, battery status reports are not sent.

The default ‘tick time’ (see other parameter settings) is 30, meaning 30 minutes. The default value of this parameter is 12, meaning that a battery report will be sent every 6 hours (12 * 30 minutes).

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 127
Default Value 12

20: Tick Interval

Interval time for sending reports

Overview

This setting is used by the battery reporting interval setting. This setting defines the ‘tick interval’ or the number of time blocks to wait between sending reports. The default value of 30 means that a tick interval is 30 minutes.

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 127
Default Value 30

Did you spot an error in the above definition or want to improve the content? You can edit the database here.