PST02B Slim Multi-Sensor (PIR/Temperature/Illumination)

This describes the Z-Wave device PST02B, manufactured by Philio Technology Corp with the thing type UID of philio_pst02b_00_000.

Slim Multi-Sensor (PIR/Temperature/Illumination)

Channels

The following table summarises the channels available for the PST02B Slim Multi-Sensor (PIR/Temperature/Illumination).

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the PST02B Slim Multi-Sensor (PIR/Temperature/Illumination). Detailed information on each parameter can be found below.

Parameter Description
2: Basic Set Level BASIC command value sent when turning on lights
3: PIR Sensitivity PIR Sensitivity setting.
4: Light Threshold Illumination threshold for turning on associated lights.
5: Operation Mode Mode of operation and enabled multisensor functions
6: Multisensor Function Switch Enable or disable functions of the multisensor.
7: Customer Function Enable or disable functions of the multisensor.
8: PIR Re-Detect Interval Time Time period to wait until reporting motion detected again.
9: Turn Off Light Time Time to wait before sending command to turn off lights
10: Auto Report Battery Time The interval time for auto reporting the battery level.
12: Auto Report Illumination Time The interval time for auto reporting the illumination state
13: Auto Report Temperature Time The interval time for auto reporting the temperature.
1: Reports  
2: Light Control  

2: Basic Set Level

BASIC command value sent when turning on lights

Overview

BASIC command value to send when turning on the light.

  • -1 (0xFF): turn on the light
  • 0: turn off the light
  • 1–100: send this dimmer value
Property Value
Configuration ID config_2_1
Data Type INTEGER
Range -1 to 100
Default Value -1

3: PIR Sensitivity

PIR Sensitivity setting.

Overview

Sensitivity for the PIR (Passiv Infrared) sensor

  • 0: Disable PIR motion detection.
  • 1–99: Motion detection sensitivity, where 1 is the lowest and 99 is the highest.
Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 99
Default Value 70

4: Light Threshold

Illumination threshold for turning on associated lights.

Overview

When the event is triggered and the environment illumination is lower than the threshold, the device will turn on the associated lights.

  • 0: turn off the illumination detection function and never turn on the lights
  • 1: darkest threshold level
  • 99 brightest threshold level
  • 100: turn off the illumination detection function and always turn on the lights.

Note: when not in test mode, only values in the range 1–99 will enable the illumination detection function and update the illumination value.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 100
Default Value 100

5: Operation Mode

Mode of operation and enabled multisensor functions

Overview

Bitfield for setting the device in certain modes and enabling or disabling specific functions of the multisensor device.

  • Bit 0: reserved.
  • Bit 1: device mode. 0 = normal mode; 1 = test mode.
  • Bit 2: disable the door/window function. 0 = enabled; 1 = disabled.
  • Bit 3: temperature unit. 0 = Fahrenheit; 1 = Celcius.
  • Bit 4: disable the illumination report after event triggered. 0 = enabled; 1 = disabled.
  • Bit 5: disable the temperature report after event triggered. 0 = enabled; 1 = disabled.
  • Bit 6: reserved.
  • Bit 7: disable the back key release into test mode. 0 = enabled; 1 = disabled.
Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 0 to 127
Default Value 0

6: Multisensor Function Switch

Enable or disable functions of the multisensor.

Overview

Bitfield for enabling or disabling functions of the multisensor.

  • Bit 0: Disable magnetic integrate illumination.
  • Bit 1: Disable PIR integrate Illumination.
  • Bit 2: Disable magnetic integrate PIR (Default is 1 = disabled).
  • Bit 3: When bit 2 is 0 (enabled), is the device is installed in the same room as the light? 0 = In the same room; 1 = In another room.

    • Note: If this bit is 1, it is recommended to also set bit 1 to 1, because when the PIR triggered, it doesn’t mean that a person is in the room where the lights are.
  • Bit 4: Disable the 5 seconds delay to turn off the light, when door/window is closed.
  • Bit 5: Disable auto turn off the light, after door/window opened to turn on the light.

    • Note: If bit 2 is 0, this setting has no effect.
    • Note: If configuration parameter is 0, **this setting has no effect.
  • Bit 6: Reserved
  • Bit 7: Reserved
Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 0 to 63
Default Value 4

7: Customer Function

Enable or disable functions of the multisensor.

Overview

Bitfield for enabling or disabling certain customer functions of the multisensor device.

  • Bit 0: Reserved.
  • Bit 1: Enable sending motion OFF report. 0=Disable; 1=Enable. Note: Depends on the value of bit 4, see below:

    • Bit 4 is 0: Report Notification CC, Type: 0x07, Event: 0xFE.
    • Bit 4 is 1: Sensor Binary Report, Type: 0x0C, Value: 0x00.
  • Bit 2: Enable PIR super sensitivity mode. 0=Disable; 1=Enable.
  • Bit 3: Disable sending BASIC OFF after door/window is closed. 1=Disable, 0=Enable.
  • Bit 4: Notification type. 0=Using Notification Report; 1=Using Sensor Binary Report.
  • Bit 5: Disable Multi CC in auto report. 1=Disable; 0=Enable.
  • Bit 6: Disable reporting battery state when the device is triggered. 1=Disable; 0=Enable.
  • Bit 7: Reserved.
Property Value      
Configuration ID config_7_1      
Data Type INTEGER      
Range 0 to 127   Default Value 0
Options Preset for motion detection settings. (22)      

8: PIR Re-Detect Interval Time

Time period to wait until reporting motion detected again.

Overview

After sending a “motion detected” report, wait at least the configured number of seconds before sending a new “motion detected” report.

The timeout is the configured value multiplied with 8 seconds, i.e. value 3 (the default) means 24 seconds timeout.

Note: This setting applies to normal mode only.

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 1 to 127
Default Value 3

9: Turn Off Light Time

Time to wait before sending command to turn off lights

Overview

When a BASIC SET command has been sent to turn on lights and motion is no longer detected by the PIR sensor, wait the configured time before sending a “turn off light” command.

The timeout is the configured value multiplied with 8 seconds, i.e. value 4 (the default) means 32 seconds timeout.

0 means “never turn off the lights”.

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 127
Default Value 4

10: Auto Report Battery Time

The interval time for auto reporting the battery level.

Overview

The interval time for auto reporting the battery level. The value is multiplied with the value of configuration parameter 20 and the unit is minutes. If the value is 0, auto reporting of battery level is turned off.

If this parameter has its default value (12) and parameter 20 has its default value (30), the interval time is 6 hours.

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 127
Default Value 12

12: Auto Report Illumination Time

The interval time for auto reporting the illumination state

Overview

The interval time for auto reporting the battery level. The value is multiplied with the value of configuration parameter 20 and the unit is minutes. If the value is 0, auto reporting of illumination is turned off.

If this parameter has its default value (12) and parameter 20 has its default value (30), the interval time is 6 hours.

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 0 to 127
Default Value 12

13: Auto Report Temperature Time

The interval time for auto reporting the temperature.

Overview

The interval time for auto reporting the temperature. The value is multiplied with the value of configuration parameter 20 and the unit is minutes. If the value is 0, auto reporting of temperature is turned off.

If this parameter has its default value (12) and parameter 20 has its default value (30), the interval time is 6 hours.

Property Value
Configuration ID config_13_1
Data Type INTEGER
Range 0 to 127
Default Value 12

1: Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Light Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to