BTZW125 Danalock v2 circle

This describes the Z-Wave device BTZW125, manufactured by Poly-control with the thing type UID of polycontrol_btzu125_00_000.

BTZW125 product image

The BTZW125 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the BTZW125 -:

Channel Channel Id Category Item Type
Door Lock lock_door Door Switch
Battery Level battery-level Battery Number

Door Lock

Lock and unlock the door.

The lock_door channel supports the Switch item and is in the Door category.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the BTZW125. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Direction Direction
2 Speed (Torque) Speed (Torque)
3 Mode Mode
4 Turn degrees Turn degrees
5 Auto Latch time Auto Latch time
6 Sound Sound
7 Battery Type Battery Type
8 Battery alarm Battery alarm value
9 TurnAndGo TurnAndGo
10 BrakeAndGoBack Turn 75 degrees back after x seconds
11 Async Used if the lock is using an optional rotation sensor
12 ReportType Door lock operation report type
  Lock Timeout Sets the time after which the door will auto lock

Parameter 1: Direction

Direction 0 -> The motor goes clockwise when latched

1 -> The motor goes counterclockwise when latched The following option values may be configured -:

Value Description
0 Clockwise
1 The motor goes counterclockwise when latched

The manufacturer defined default value is 0 (Clockwise).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Speed (Torque)

Speed (Torque) 1 -> Slowest

2 -> Slow

3 -> (Default) Normal

4 -> Fast

5 -> Fastest The following option values may be configured -:

Value Description
1 Slowest
2 Slow
3 Normal
4 Fast
5 Fastest

The manufacturer defined default value is 3 (Normal).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Mode

Mode 0 -> Stepper motor mode wave drive(power saving)

1 -> (Default) Stepper motor mode full drive(Normal)

2 -> Relay mode The following option values may be configured -:

Value Description
0 Powersaving
1 Full drive
2 Relay mode

The manufacturer defined default value is 1 (Full drive).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Turn degrees

Turn degrees (Default) Factor 10 turn degrees ( 1 = 10 degrees, 9 = 90 degrees etc.) Values in the range 1 to 100 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Auto Latch time

Auto Latch time How many seconds from the lock has been unlatched to it automatically should close again. If 0 then it is disabled. Values in the range 0 to 60 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Sound

Sound Enable the beep sound from latch or unlatch operations The following option values may be configured -:

Value Description
0 Disable sound
1 Enable Sound

The manufacturer defined default value is 1 (Enable Sound).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Battery Type

Battery Type 2 -> Mains power, changing from and to mains power requires the Danalock to be excluded and included.

0 -> 3,6 Volt battery

1 -> (Default) 3.0 Volt battery. The following option values may be configured -:

Value Description
0 3,6V
1 3,0V
2 Mains power

The manufacturer defined default value is 1 (3,0V).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Battery alarm

Battery alarm value When the battery level is under this value, the device will notify user with a beep sound after latch or unlatch Values in the range 0 to 100 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: TurnAndGo

TurnAndGo using a optional rotation sensor. Latch&Go on will turn automatically when manual turn is detected. The following option values may be configured -:

Value Description
0 Off
1 On

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: BrakeAndGoBack

Turn 75 degrees back after x seconds 0 -> (Default) Disabled

1 to 15 -> Seconds to brake. When used the lock will brake for x amount of seconds and then turn 75 degrees back. Made for special doors without door lever.(Only when unlatching). The following option values may be configured -:

Value Description
0 Disabled
1 1 second
2 Brake for 2 seconds
3 Brake for 3 seconds
4 Brake for 4 seconds
5 Brake for 5 seconds
6 Brake for 6 seconds
7 Brake for 7 seconds
8 Brake for 8 seconds
9 Brake for 9 seconds
10 Brake for 10 seconds
11 Brake for 11 seconds
12 Brake for 12 seconds
13 Brake for 13 seconds
14 Brake for 14 seconds
15 Brake for 15 seconds

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Async

Used if the lock is using an optional rotation sensor 0 -> (Default) Async off

1 -> Async on. Used if the lock is using an optional rotation sensor. When async is enabled the lock will auto calibrate if already unlatched and asked to Unlatch again (used for special door locks where the key turn is asynced from the inside nob.) The following option values may be configured -:

Value Description
0 Async off
1 Async on

The manufacturer defined default value is 0 (Async off).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: ReportType

Door lock operation report type Door lock operation report type

2 -> No Door lock operation reports are sent unsolicited.

0 -> (Default) Simple supported by all controllers that support door locks.

1 -> Advanced, more specific reports through notification Command Class. The following option values may be configured -:

Value Description
0 Default
1 Advanced
2 No reporting

The manufacturer defined default value is 0 (Default).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The BTZW125 supports 1 association group.

Group 1: LifeLine

Z-Wave Plus Lifeline This group supports 1 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_APPLICATION_STATUS_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V2  
COMMAND_CLASS_DOOR_LOCK_V2  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_TIME_V1  
COMMAND_CLASS_TIME_PARAMETERS_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.