Danalock V3-BTZE Z-Wave controlled door lock with Bluetooth Smart

This describes the Z-Wave device Danalock V3-BTZE, manufactured by Poly-control with the thing type UID of polycontrol_btze_00_000.

Z-Wave controlled door lock with Bluetooth Smart

Overview

Danalock supports: 
- S0/S2 Z-Wave Security 
- Bluetooth Smart 
- Twist Assist 
- Auto Lock 
- Hold And Release 
- Back To Back 

Inclusion Information

To add or include the Danalock into a Z-Wave network

  1. Set the controller in inclusion mode
  2. Push the switch once.
  3. Wait 5 seconds. 

Exclusion Information

To remove or exclude the Danalock into a Z-Wave network

  1. Set the controller in exclusion mode
  2. Push the switch once.
  3. Wait 5 seconds. 

Channels

The following table summarises the channels available for the Danalock V3-BTZE Z-Wave controlled door lock with Bluetooth Smart.

Channel Channel Id Channel Type UID Category Item Type
Door Lock lock_door lock_door Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the Danalock V3-BTZE Z-Wave controlled door lock with Bluetooth Smart. Detailed information on each parameter can be found below.

Parameter Description
1: Twin Assist Helps you to lock and unlock your door lock.
2: Hold and Release After a unlock operation the lock holds the lock, so the door can be opened
3: Block to block The lock will run the motor until it hits resistance.
4: BLE Temporary Allowed The BLE is enabled for a number of seconds.
5: BLE Always Allowed BLE Always Allowed
6: Autolock Lock after an unlock.Value is delay in sec before lock is locked again.
1: Lifeline Z-Wave Plus Lifeline

1: Twin Assist

Helps you to lock and unlock your door lock.

Overview

0 -> disabled

1 -> enabled

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options disabled (0)      
  enabled (1)      

2: Hold and Release

After a unlock operation the lock holds the lock, so the door can be opened

Overview

0 -> disabled

1 to 2147483647 -> enabled no. of seconds

Property Value      
Configuration ID config_2_4      
Data Type INTEGER   Default Value 0
Options (0)      

3: Block to block

The lock will run the motor until it hits resistance.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

4: BLE Temporary Allowed

The BLE is enabled for a number of seconds.

Overview

0 -> Disabled

1 to 2147483647 -> enabled no. of seconds

Property Value
Configuration ID config_4_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 0

5: BLE Always Allowed

BLE Always Allowed

Overview

0 -> BLE Always disabled

1 -> BLE Always enabled

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options BLE Always disabled (0)      
  BLE Always enabled (1)      

6: Autolock

Lock after an unlock.Value is delay in sec before lock is locked again.

Overview

0 -> disabled

1 to 2147483647 -> enabled no. of seconds

Property Value
Configuration ID config_6_4
Data Type INTEGER
Range 0 to 2147483647
Default Value 0

1: Lifeline

Z-Wave Plus Lifeline

Overview

Z-Wave Plus Lifeline • Device Reset Locally: triggered upon reset. • Battery/notification: triggered upon low battery. • Door Lock operation report: triggered upon a change in door lock • Notification: triggered upon a change in door lock

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.