005107 Solar Powered Outdoor Siren

This describes the Z-Wave device 005107, manufactured by Popp & Co with the thing type UID of popp_005107_01_001. This version of the device is limited to firmware version 1.1

The device is in the category of Siren, defining Siren used by Alarm systems.

005107 product image

The 005107 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the 005107 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Binary Sensor sensor_binary Door Switch
Sensor (temperature) sensor_temperature Temperature Number
Alarm alarm_general Door Switch
Battery Level battery-level Battery Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 5 configuration parameters available in the 005107. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Siren triggering mode Sets the tamper triggering mode when removed from the holder
2 Temperature adjustments Temperature correction with positive and negative offset values
3 Send unsolicited temperature report Threshold temperature to send unsolicited report. 10 = 1°C
4 Send unsolicited temperature report after N wake up Send unsolicited temperature report after N wake up
5 Switch mode Switch mode : siren only, flash only, flash + siren

Parameter 1: Siren triggering mode

Sets the tamper triggering mode when removed from the holder

The following option values may be configured -:

Value Description
0 Trigger, when removed from holder
1 Trigger, when removed, and turn off, when placed back.
2 Don’t trigger at all

The manufacturer defined default value is 0 (Trigger, when removed from holder).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Temperature adjustments

Temperature correction with positive and negative offset values Temperature correction. For positive value 10 = 1 °C, for negative value x = 256 - (T°C * 10).

Example, if need shift -2.6°C, value calculate: 256 - (2.6 * 10) = 230. The following option values may be configured, in addition to values in the range 0 to 255 -:

Value Description
0 Temperature adjustments

The manufacturer defined default value is 0 (Temperature adjustments).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Send unsolicited temperature report

Threshold temperature to send unsolicited report. 10 = 1°C In 0.1°C (Default 10) Values in the range 0 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Send unsolicited temperature report after N wake up

Send unsolicited temperature report after N wake up Send unsolicited temperature report after N wake up

If the value is set, after N wake up number (measurement is every 4 minutes) the temperature report will be sent.

By default it’s 15 = every 1 hour The following option values may be configured -:

Value Description
0 Send unsolicited temperature report after N wake up

The manufacturer defined default value is 15.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Switch mode

Switch mode : siren only, flash only, flash + siren

The following option values may be configured -:

Value Description
0 Siren only
1 Flash only
2 Flash + Siren (Default)

The manufacturer defined default value is 2 (Flash + Siren (Default)).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 005107 supports 1 association group.

Group 1: Lifeline

Lifeline (max. nodes in group: 10) This group supports 10 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SENSOR_BINARY_V2  
COMMAND_CLASS_SENSOR_MULTILEVEL_V5  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.