004407 CO Detector

This describes the Z-Wave device 004407, manufactured by Popp & Co with the thing type UID of popp_004407_01_000.

CO Detector

Overview

This product combines a certified carbon monoxide detector with a plug-in Z-Wave module to form a wirelessly reporting carbon monoxide sensor. The carbon monoxide detector is certified according to EN 50270:1999, EN 60335-1:1994 as well as EN 50291:2001 and satisfies all contemporary legal requirements.

There is no defined level of carbon monoxide that will result in an alarm. The danger of CO is a result of the total level of CO in the air plus the duration of exposure. A Z-Wave alarm will be sent out when one of the following conditions were met:

  • CO level above 43 ppm for a duration of 60 minutes
  • CO level above 80 ppm for a duration of 10 minutes
  • CO level above 150 ppm for a duration of 2 minutes

Inclusion Information

Pressing the Z-Wave button for one second includes the device. If the button is pressed for at least 2 seconds, the inclusion will be done without the Security Command Class.

Exclusion Information

A single click on the Z-Wave button will exclude the device.

Wakeup Information

Wakeup is done by single push of the Z-Wave button

Channels

The following table summarises the channels available for the 004407 CO Detector.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (CARBON_MONOXIDE) sensor_co sensor_co   Number
Alarm (system) alarm_system alarm_system   Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Alarm (CO) alarm_co alarm_co Door Switch
Alarm (general) alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the 004407 CO Detector. Detailed information on each parameter can be found below.

Parameter Description
1: Value of ON-Command  
2: Value of OFF-Command  
1: Lifeline  
2: Switching Command when Alarm  

1: Value of ON-Command

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 99
Default Value 99

2: Value of OFF-Command

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 99
Default Value 0

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Switching Command when Alarm

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.