005107 Solar Powered Outdoor Siren

This describes the Z-Wave device 005107, manufactured by Popp & Co with the thing type UID of popp_005107_01_001.

Solar Powered Outdoor Siren

Channels

The following table summarises the channels available for the 005107 Solar Powered Outdoor Siren.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the 005107 Solar Powered Outdoor Siren. Detailed information on each parameter can be found below.

Parameter Description
1: Siren triggering mode Sets the tamper triggering mode when removed from the holder
2: Temperature adjustments Temperature correction with positive and negative offset values
3: Send unsolicited temperature report Threshold temperature to send unsolicited report. 10 = 1°C
4: Send unsolicited temperature report after N wake up Send unsolicited temperature report after N wake up
5: Switch mode Switch mode : siren only, flash only, flash + siren
1: Lifeline Lifeline (max. nodes in group: 10)

1: Siren triggering mode

Sets the tamper triggering mode when removed from the holder

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Siren triggering mode (0)      
  Siren triggering mode (1)      
  Siren triggering mode (2)      

2: Temperature adjustments

Temperature correction with positive and negative offset values

Overview

Temperature correction. For positive value 10 = 1 °C, for negative value x = 256 -  (T°C * 10).

Example, if need shift -2.6°C, value calculate: 256 -  (2.6 * 10) = 230.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER      
Range 0 to 255   Default Value 0
Options Temperature adjustments (0)      

3: Send unsolicited temperature report

Threshold temperature to send unsolicited report. 10 = 1°C

Overview

In 0.1°C (Default 10)

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 255
Default Value 10

4: Send unsolicited temperature report after N wake up

Send unsolicited temperature report after N wake up

Overview

Send unsolicited  temperature report after N wake up

If the value is set, after N wake up number (measurement is every 4 minutes) the  temperature report will be sent.

By default it’s 15 = every 1 hour

Property Value      
Configuration ID config_4_2      
Data Type INTEGER   Default Value 15
Options Send unsolicited temperature report after N wake up (0)      

5: Switch mode

Switch mode : siren only, flash only, flash + siren

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 2
Options Switch mode (0)      
  Switch mode (1)      
  Switch mode (2)      

1: Lifeline

Lifeline (max. nodes in group: 10)

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.