009204 KFOB-C Remote-Control

This describes the Z-Wave device 009204, manufactured by Popp & Co with the thing type UID of popp_009204_00_000.

KFOB-C Remote-Control

Channels

The following table summarises the channels available for the 009204 KFOB-C Remote-Control.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the 009204 KFOB-C Remote-Control. Detailed information on each parameter can be found below.

Parameter Description
1: Button 1 and 3 pair mode In separate mode button 1 works with Group A, button 3 with Group C.
2: Button 2 and 4 pair mode In separate mode button 2 works with group B, button 4 with group D.
11: Command to control Group A This parameter defines the command to be sent to devices of control group A
12: Command to control Group B This parameter defines the command to be sent to devices of control group B
13: Command to control Group C This parameter defines the command to be sent to devices of control group C
14: Command to control Group D This parameter defines the command to be sent to devices of control group D
21: Send the following Switch All commands  
22: Invert buttons  
25: Blocks wake up even when Wake Up Interval is set  
30: Send unsolicited Battery Report on Wake Up  
1: Controlled by button 1 or single clicks of buttons 1 and 3  
2: Controlled by button 3 or double clicks of buttons 1 and 3  
3: Controlled by button 2 or single clicks of buttons 2 and 4  
4: Controlled by button 4 or double clicks of buttons 2 and 4  

1: Button 1 and 3 pair mode

In separate mode button 1 works with Group A, button 3 with Group C.

Overview

In separate mode button 1 works with Group A, button 3 with Group C. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair button 1/3 are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group A, double click with Group C

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (1)      
  In pair with double clicks (2)      

2: Button 2 and 4 pair mode

In separate mode button 2 works with group B, button 4 with group D.

Overview

In separate mode button 2 works with control group B, button 4 with control group D. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair button B/D are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group B, double click with Group D.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (1)      
  In pair with double clicks (2)      

11: Command to control Group A

This parameter defines the command to be sent to devices of control group A

Overview

This parameter defines the command to be sent to devices of control group A when the related button is pressed.

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 8
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (default) (8)      

12: Command to control Group B

This parameter defines the command to be sent to devices of control group B

Overview

This parameter defines the command to be sent to devices of control group B when the related button is pressed.

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 8
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (default) (8)      

13: Command to control Group C

This parameter defines the command to be sent to devices of control group C

Overview

This parameter defines the command to be sent to devices of control group C when the related button is pressed.

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 8
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (default) (8)      

14: Command to control Group D

This parameter defines the command to be sent to devices of control group D

Overview

This parameter defines the command to be sent to devices of control group D when the related button is pressed.

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 8
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (default) (8)      

21: Send the following Switch All commands

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 1
Options NO (Normal Open) (1)      
  NC (Normal Close) (2)      
  Switch all on and off (255)      

22: Invert buttons

Property Value      
Configuration ID config_22_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

25: Blocks wake up even when Wake Up Interval is set

Overview

If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery.

Property Value      
Configuration ID config_25_1      
Data Type INTEGER   Default Value 0
Options Wake up is blocked (default) (0)      
  Wake up is possible if configured accordingly (1)      

30: Send unsolicited Battery Report on Wake Up

Overview

If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery. Value

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 1
Options No (0)      
  To same node as wake up notification (1)      
  Broadcast to neighbours (2)      

1: Controlled by button 1 or single clicks of buttons 1 and 3

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Controlled by button 3 or double clicks of buttons 1 and 3

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controlled by button 2 or single clicks of buttons 2 and 4

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Controlled by button 4 or double clicks of buttons 2 and 4

Property Value
Configuration ID group_4
Data Type TEXT
Range to