009303 Wall Controller

This describes the Z-Wave device 009303, manufactured by Popp & Co with the thing type UID of popp_009303_00_000.

Wall Controller

Inclusion Information

see attached file “Popp 009303 Battery Wall Controller Manual” (section Reference Documents)

Exclusion Information

see attached file “Popp 009303 Battery Wall Controller Manual” (section Reference Documents)

Wakeup Information

see attached file “Popp 009303 Battery Wall Controller Manual” (section Reference Documents)

Channels

The following table summarises the channels available for the 009303 Wall Controller.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Activation scene_number scene_number   Number
Scene Number scene_number scene_number   Number
  battery-level system.battery-level    

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the 009303 Wall Controller. Detailed information on each parameter can be found below.

Parameter Description
1: Button 1 and 3 pair mode Button 1 and 3 pair mode.
2: Button 2 and 4 pair mode Button 2 and 4 pair mode.
11: Command to control Group A Defines the command to be sent to devices of control group A when the related button is pr…
12: Command to control Group B Defines the command to be sent to devices of control group B when the related button is pr…
13: Command to control Group C Defines the command to be sent to devices of control group C when the related button is pr…
14: Command to control Group D Defines the command to be sent to devices of control group D when the related button is pr…
21: Send the following switch all commands  
22: Invert buttons  
25: Block wake up even when Wake Up Interval is set  
30: End unsolicited battery report on Wake Up.  
1: Lifeline  
2: Control Group A  
3: Control Group B  
4: Control Group C  
5: Control Group D  

1: Button 1 and 3 pair mode

Button 1 and 3 pair mode.

Overview

In separate mode button 1 works with Group A, button 3 with Group C. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair button 1/3 are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group A, double click with Group C.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (Default) (1)      
  In pair with double clicks (2)      

2: Button 2 and 4 pair mode

Button 2 and 4 pair mode.

Overview

In separate mode button 2 works with control group B, button 4 with control group D. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair button B/D are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group B, double click with Group D.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (Default) (1)      
  In pair with double clicks (2)      

11: Command to control Group A

Defines the command to be sent to devices of control group A when the related button is pressed.

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 8
Options Disable (0)      
  Switch on/off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch on/off only (send Basic Set) (2)      
  Switch all (3)      
  Send scenes (4)      
  Send preconfigured scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (default) (8)      

12: Command to control Group B

Defines the command to be sent to devices of control group B when the related button is pressed.

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 8
Options Disable (0)      
  Switch on/off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch on/off only (send Basic Set) (2)      
  Switch all (3)      
  Send scenes (4)      
  Send preconfigured scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (default) (8)      

13: Command to control Group C

Defines the command to be sent to devices of control group C when the related button is pressed.

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 8
Options Disable (0)      
  Switch on/off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch on/off only (send Basic Set) (2)      
  Switch all (3)      
  Send scenes (4)      
  Send preconfigured scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (default) (8)      

14: Command to control Group D

Defines the command to be sent to devices of control group D when the related button is pressed.

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 8
Options Disable (0)      
  Switch on/off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch on/off only (send Basic Set) (2)      
  Switch all (3)      
  Send scenes (4)      
  Send preconfigured scenes (5)      
  Control devices in proximity (6)      
  Control door lock (7)      
  Central scene to gateway (default) (8)      

21: Send the following switch all commands

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 1
Options Switch off only (default) (1)      
  Switch on only (2)      
  Switch all on and off (255)      

22: Invert buttons

Property Value      
Configuration ID config_22_1      
Data Type INTEGER   Default Value 0
Options No (default) (0)      
  Yes (1)      

25: Block wake up even when Wake Up Interval is set

Property Value      
Configuration ID config_25_1      
Data Type INTEGER   Default Value 0
Options Wake up is blocked (default) (0)      
  Wake up is possible if configured accordingly (1)      

30: End unsolicited battery report on Wake Up.

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  To same node as Wake Up Notification (default) (1)      
  Broadcast to neighbors (2)      

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Control Group A

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Control Group B

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Control Group C

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Control Group D

Property Value
Configuration ID group_5
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.