009501 Popp 09501 Flow Stop

This describes the Z-Wave device 009501, manufactured by Popp & Co with the thing type UID of popp_009501_01_002.

Popp 09501 Flow Stop

Overview

The Flow Stop moves the operating handle of a ball valve allowing to stopping the flow of gas or water. It can be mounted non-intrusive on any pipe size between 0.5 and 1.5 inch. This means the original water or gas pipe will not be opened or manipulated and it is possible to remove the Flow stop again without any damage to the water or gas pipe. Installing the Flow stop will not tamper or change any security measure applied or your gas or water installation.
The device is equipped with a powerful 12 V motor providing sufficient torque to open or close any ball valve within 10 seconds. A complete manual operation of the valve remains possible due to the clutch release bearing.

Inclusion Information

For inclusion press the red button on the top of the enclosure 3 times

Exclusion Information

For exclusion press the red button on the top of the enclosure 3 times

Channels

The following table summarises the channels available for the 009501 Popp 09501 Flow Stop.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the 009501 Popp 09501 Flow Stop. Detailed information on each parameter can be found below.

Parameter Description
0: LED Status No help available, self explanatory….
1: Shut-off controller behavior The parameter defines how to control the shut-off controller.
1: LifeLine  
2: Local Valve Operation  

0: LED Status

No help available, self explanatory….

Overview

0: LED always ON (Only on operation OFF)
1: LED always OFF (Only on operation ON)

Property Value
Configuration ID config_0_1
Data Type INTEGER
Range 0 to 1
Default Value 0

1: Shut-off controller behavior

The parameter defines how to control the shut-off controller.

Overview

0: Remote and manually open/close
1: Remote open/close only
2: Only remote open; only manually closing
3: Only manually open; only remote closing
4: Manually open/close only

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 4
Default Value 0

1: LifeLine

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Local Valve Operation

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.