123580 Wall Plug Dimmer

This describes the Z-Wave device 123580, manufactured by Popp & Co with the thing type UID of popp_123580_00_000.

Wall Plug Dimmer

Channels

The following table summarises the channels available for the 123580 Wall Plug Dimmer.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the 123580 Wall Plug Dimmer. Detailed information on each parameter can be found below.

Parameter Description
1: Set LED indication mode  
2: Automatic switch off time If not zero, automatically switch off after a user defined time (in seconds)
3: RF Off command Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function…
4: Ignore start level  
5: Speed for fast dimming Time to dim on button presses and Set command (if it has no duration specified). If not 0,…
6: Speed for slow dimming Time to dim on button presses and Set command (if it has no duration specified). If not 0,…
7: Behavior when ON received Defines the dim level on command ‘ON’. On default he dimmer restores last dim level. This …
8: Baby dimming time Time to dim on double click Off button for Baby-Dim function. This function works only if …
9: Baby target level Target percentage level on which to stop while executing Baby Dimming. Can be 0 to complet…
10: Baby target level Typical time used to differentiate click, hold, double and triple clicks. Set in 10ms step…
17: Limit minimum light level Minimum level should be greater than maximum.
18: Limit maximum light level Maximum level should be greater than minimum. Set to 0 to act as a switch.
19: Dim Level on 'Switch On' defines how the dimmer hall react on a simple ON Command. Set to 0 to restore last level, …
51: Pause before pulse NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and …
52: Pause after pulse NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and …
53: Pulse width NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and …
54: Pulse type NB: Do not touch these settings if you are not sure what they mean!
1: Switch State  

1: Set LED indication mode

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  On when switch on (1)      
  On when switch off (2)      
  Operated by command (3)      

2: Automatic switch off time

If not zero, automatically switch off after a user defined time (in seconds)

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

3: RF Off command

Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Switch OFF (0)      
  Ignore (1)      
  Switch ON (2)      
  Switch on if load is off else switch off (3)      

4: Ignore start level

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options No (0)      
  Yes (1)      

5: Speed for fast dimming

Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserve bulb life. Set in 10ms steps.

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 0 to 255
Default Value 30

6: Speed for slow dimming

Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserve bulb life. Set in 10ms steps.

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 0 to 255
Default Value 3

7: Behavior when ON received

Defines the dim level on command ‘ON’. On default he dimmer restores last dim level. This parameter allows configuring the maximum level on second On command (if already On) or to always switch on to maximum level.

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 0
Options Set to last dim level (0)      
  If on already, set to maximum (1)      
  Always maximum dim level (2)      

8: Baby dimming time

Time to dim on double click Off button for Baby-Dim function. This function works only if the load is operated by single press and hold button action. If enabled, the device will wait for a click timeout to see if the second click would be pressed. This w

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 0 to 99
Default Value 0

9: Baby target level

Target percentage level on which to stop while executing Baby Dimming. Can be 0 to completely switch off the light.

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 100
Default Value 0

10: Baby target level

Typical time used to differentiate click, hold, double and triple clicks. Set in 10ms steps.

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 100
Default Value 50

17: Limit minimum light level

Minimum level should be greater than maximum.

Property Value
Configuration ID config_17_1
Data Type INTEGER
Range 1 to 95
Default Value 1

18: Limit maximum light level

Maximum level should be greater than minimum. Set to 0 to act as a switch.

Property Value
Configuration ID config_18_1
Data Type INTEGER
Range 0 to 99
Default Value 1

19: Dim Level on 'Switch On'

defines how the dimmer hall react on a simple ON Command. Set to 0 to restore last level, otherwise sets dim level.

Property Value
Configuration ID config_19_1
Data Type INTEGER
Range 0 to 99
Default Value 1

51: Pause before pulse

NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 1. For other bulbs use default value.

Property Value
Configuration ID config_51_1
Data Type INTEGER
Range 5 to 60
Default Value 28

52: Pause after pulse

NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 40. For other bulbs use default value.

Property Value
Configuration ID config_52_1
Data Type INTEGER
Range 5 to 60
Default Value 28

53: Pulse width

NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 20. For other bulbs use default value.

Property Value
Configuration ID config_53_1
Data Type INTEGER
Range 3 to 20
Default Value 10

54: Pulse type

NB: Do not touch these settings if you are not sure what they mean!

Property Value      
Configuration ID config_54_1      
Data Type INTEGER   Default Value 0
Options Long (0)      
  Short (1)      

1: Switch State

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.