123610 Wall Plug Switch

This describes the Z-Wave device 123610, manufactured by Popp & Co with the thing type UID of popp_123610_00_000.

Wall Plug Switch

Channels

The following table summarises the channels available for the 123610 Wall Plug Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the 123610 Wall Plug Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Set LED indication mode  
2: Automatic switch off time If not zero, automatically switch off after a user defined time (in seconds)
3: RF Off command Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function…
5: Restore switch state after power cycle Defines if the switch should restore switch state to the last state prior to device power …
1: Switch State  

1: Set LED indication mode

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  On when switch on (1)      
  On when switch off (2)      
  Operated by command (3)      

2: Automatic switch off time

If not zero, automatically switch off after a user defined time (in seconds)

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

3: RF Off command

Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Switch OFF (0)      
  Ignore (1)      
  Switch ON (2)      
  Switch on if load is off else switch off (3)      

5: Restore switch state after power cycle

Defines if the switch should restore switch state to the last state prior to device power off (power cycle).

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options No - turn OFF (0)      
  Yes (1)      

1: Switch State

Property Value
Configuration ID group_1
Data Type TEXT
Range to