123665 Wall Plug Meter Switch

This describes the Z-Wave device 123665, manufactured by Popp & Co with the thing type UID of popp_123665_00_000.

Wall Plug Meter Switch

Channels

The following table summarises the channels available for the 123665 Wall Plug Meter Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (amps) meter_current meter_current Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the 123665 Wall Plug Meter Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Watt Meter Report Period If the setting is configured for 1hour (set value =720), the device will report its instan…
2: KWH Meter Report Period if the setting is configured for 1hour (set value =6), the device will report its Accumula…
4: Threshold of KWh for Load caution This is a warning when the KWh of load over the preset threshold value, if the Accumulated…
5: Ignore start level  
11: Ignore start level  
1: Switch State  

1: Watt Meter Report Period

If the setting is configured for 1hour (set value =720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. (in seconds)

Property Value      
Configuration ID config_1_2      
Data Type INTEGER      
Range 0 to 65535   Default Value 720
Options TEST (99999)      

2: KWH Meter Report Period

if the setting is configured for 1hour (set value =6), the device will report its Accumulated Power Consumption (KW/h) every hour (in seconds)

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 6

4: Threshold of KWh for Load caution

This is a warning when the KWh of load over the preset threshold value, if the Accumulated Power Consumption exceeds the setting value the device will send a warning alarm command to the controller.

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 65535
Default Value 10000

5: Ignore start level

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options (0)      
  Last Switch State (Default) (1)      
  Switch On (2)      

11: Ignore start level

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Enabled (Default) (1)      

1: Switch State

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.