ED2.0 Eneco Meter Adapter

This describes the Z-Wave device ED2.0, manufactured by Prodrive Technologies with the thing type UID of prodrive_ed20_00_000.

Eneco Meter Adapter

Overview

The meter adapter measures gas and electricity usage of analog and digital meters. Analog meters are read by means of optical sensors that can be placed on the meter to monitor the rotating disc or the blinking LED. In case of a digital meter, the meter adapter can be connected to the digital meter by means of a P1 digital communication interface. The meter adapter measures the cumulative and instantaneous gas and electricity consumption and sends this information to a Z-Wave enabled display (ED2.0 Display).

Inclusion Information

Press Button

Channels

The following table summarises the channels available for the ED2.0 Eneco Meter Adapter.

Channel Channel Id Channel Type UID Category Item Type
Clock Time Offset time_offset time_offset Temperature Number
Gas meter (cubic meters) meter_gas_cubic_meters1 meter_gas_cubic_meters Energy Number
Electric meter (kWh) meter_kwh2 meter_kwh Energy Number
Electric meter (kWh) meter_kwh3 meter_kwh Energy Number
Electric meter (kWh) meter_kwh4 meter_kwh Energy Number
Electric meter (kWh) meter_kwh5 meter_kwh Energy Number
Electric meter (kWh) meter_kwh6 meter_kwh Energy Number

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ED2.0 Eneco Meter Adapter. Detailed information on each parameter can be found below.

Parameter Description
0: Gas Metering Enable and disable gas metering
1: Gas Meter resolution The resolution of the analog gas meter
2: Electricity metering Enable and disable Electricity metering
3: Electricity meter resolution The resolution of the analog electricity meter

0: Gas Metering

Enable and disable gas metering

Property Value      
Configuration ID config_0_1      
Data Type INTEGER   Default Value 1
Options disable gas metering (0)      
  enable gas metering (1)      

1: Gas Meter resolution

The resolution of the analog gas meter

Overview

The resolution of the analog gas meter (revolutions per m³) in unsigned Q14.2 notation.

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 65535
Default Value 400

2: Electricity metering

Enable and disable Electricity metering

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options disable electricity metering (0)      
  enable electricity metering (1)      

3: Electricity meter resolution

The resolution of the analog electricity meter

Overview

The resolution of the analog electricity meter (revolutions per kWh) in unsigned Q14.2 notation.

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 0 to 65535
Default Value 400