ZMNHBA Flush 2 relays

This describes the Z-Wave device ZMNHBA, manufactured by Goap with the thing type UID of qubino_zmnhba_00_000.

The ZMNHBA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZMNHBA -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Sensor (temperature) sensor_temperature Temperature Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number
Switch 1 switch_binary1 Switch Switch
Electric meter (kWh) 1 meter_kwh1 Energy Number
Electric meter (watts) 1 meter_watts1 Energy Number
Switch 2 switch_binary2 Switch Switch
Electric meter (kWh) 2 meter_kwh2 Energy Number
Electric meter (watts) 2 meter_watts2 Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Electric meter (kWh) 2

Indicates the energy consumption (kWh).

The meter_kwh2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 2

Indicates the instantaneous power consumption.

The meter_watts2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 10 configuration parameters available in the ZMNHBA. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Input 1 switch type Input 1 switch type
2 Input 2 switch type Input 2 switch type
10 Activate / deactivate functions ALL ON/ALL OFF Activate / deactivate functions ALL ON/ALL OFF
11 Automatic turning off relay Q1 after set time Automatic turning off relay Q1 after set time
12 Automatic turning off relay Q2 after set time Automatic turning off relay Q2 after set time
30 Saving Q1 and Q2 after a power failure Saving the state of the relays Q1 and Q2 after a power failure
40 Power reporting in Watts on power change for Q1 Power report is sent (pushed) only when actual power in Watts in real time changed for more than set percentage comparing to previous actual power in Watts, step is 1%.
  • 0 = Reporting Disabled
  • 1–100 = 1% - 100% Reporti      
      41 Power reporting in Watts on power change for Q2 Power report is sent (pushed) only when actual power in Watts in real time changed for more than set percentage comparing to previous actual power in Watts, step is 1%.
  • 0 = Reporting Disabled
  • 1–100 = 1% - 100% Reporti      
      42 Power reporting in Watts by time interval for Q1 default value is 300 (power report in Watts is sent each 300s)
  • 0 = Reporting Disabled
  • 1–65535 = 1 second – 65535 seconds. Reporting enabled. Power report is sent with time interval set by entered value.      
      43 Power reporting in Watts by time interval for Q2 default value is 300 (power report in Watts is sent each 300s)
  • 0 = Reporting Disabled
  • 1–65535 = 1 second – 65535 seconds. Reporting enabled. Power report is sent with time interval set by entered value.      
        Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Input 1 switch type

Input 1 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Input 2 switch type

Input 2 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 10: Activate / deactivate functions ALL ON/ALL OFF

Activate / deactivate functions ALL ON/ALL OFF Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. The following option values may be configured -:

Value Description
0 ALL ON is not active ALL OFF is not active
1 ALL ON is not active ALL OFF active
2 ALL ON active ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Automatic turning off relay Q1 after set time

Automatic turning off relay Q1 after set time Auto OFF enabled with define time, step is 10 mseconds

  • 0 = Auto OFF disabled
  • 1–65535 = 0,01 second – 655,35 seconds Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: Automatic turning off relay Q2 after set time

Automatic turning off relay Q2 after set time Auto OFF enabled with define time, step is 10 mseconds

  • 0 = Auto OFF disabled
  • 1–65535 = 0,01 second – 655,35 seconds Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 30: Saving Q1 and Q2 after a power failure

Saving the state of the relays Q1 and Q2 after a power failure

The following option values may be configured -:

Value Description
0 Flush 2 relays module saves its state before power failure (it returns
1 Flush 2 relays module does not save the state after a power failure, i

The manufacturer defined default value is 0 (Flush 2 relays module saves its state before power failure (it returns).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 40: Power reporting in Watts on power change for Q1

Power report is sent (pushed) only when actual power in Watts in real time changed for more than set percentage comparing to previous actual power in Watts, step is 1%.

  • 0 = Reporting Disabled
  • 1–100 = 1% - 100% Reporti

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 41: Power reporting in Watts on power change for Q2

Power report is sent (pushed) only when actual power in Watts in real time changed for more than set percentage comparing to previous actual power in Watts, step is 1%.

  • 0 = Reporting Disabled
  • 1–100 = 1% - 100% Reporti

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_41_1 and is of type INTEGER.

Parameter 42: Power reporting in Watts by time interval for Q1

default value is 300 (power report in Watts is sent each 300s)

  • 0 = Reporting Disabled
  • 1–65535 = 1 second – 65535 seconds. Reporting enabled. Power report is sent with time interval set by entered value.

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_42_2 and is of type INTEGER.

Parameter 43: Power reporting in Watts by time interval for Q2

default value is 300 (power report in Watts is sent each 300s)

  • 0 = Reporting Disabled
  • 1–65535 = 1 second – 65535 seconds. Reporting enabled. Power report is sent with time interval set by entered value.

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_43_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHBA supports 3 association groups.

Group 1: Basic on/off Q1

This group supports 4 nodes.

Group 2: Basic on/off Q2

This group supports 4 nodes.

Group 3: Default Reporting Group

This group supports 4 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V5| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_METER_V3| |

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.