ZMNHJA Flush Pilot

This describes the Z-Wave device ZMNHJA, manufactured by Goap with the thing type UID of qubino_zmnhja_00_000.

The ZMNHJA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZMNHJA -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Dimmer switch_dimmer DimmableLight Dimmer
Sensor (temperature) sensor_temperature Temperature Number
Binary Sensor 1 sensor_binary1 Door Switch
Binary Sensor 2 sensor_binary2 Door Switch
Binary Sensor 3 sensor_binary3 Door Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Binary Sensor 1

Indicates if a sensor has triggered.

The sensor_binary1 channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Binary Sensor 2

Indicates if a sensor has triggered.

The sensor_binary2 channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Binary Sensor 3

Indicates if a sensor has triggered.

The sensor_binary3 channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Device Configuration

The following table provides a summary of the 10 configuration parameters available in the ZMNHJA. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Input 1 switch type  
2 Input 2 switch type  
3 Input 3 switch type  
4 Input 1 contact type  
5 Input 2 contact type  
6 Input 3 contact type  
11 Input 1 operation mode selection  
12 Input 2 operation mode selection  
13 Input 3 operation mode selection  
30 Saving the state of the device after a power failure  
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Input 1 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Input 2 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Input 3 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Input 1 contact type

The following option values may be configured -:

Value Description
0 NO (normally open) input type
1 NC (normally close) input type

The manufacturer defined default value is 0 (NO (normally open) input type).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Input 2 contact type

The following option values may be configured -:

Value Description
0 NO (normally open) input type
1 NC (normally close) input type

The manufacturer defined default value is 0 (NO (normally open) input type).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Input 3 contact type

The following option values may be configured -:

Value Description
0 NO (normally open) input type
1 NC (normally close) input type

The manufacturer defined default value is 0 (NO (normally open) input type).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 11: Input 1 operation mode selection

The following option values may be configured -:

Value Description
0 Button does not influence on selected mode
1 Comfort
2 Comfort-1°C
3 Comfort-2°C
4 Eco Mode
5 Frost Protection
6 Stop

The manufacturer defined default value is 1 (Comfort).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Input 2 operation mode selection

The following option values may be configured -:

Value Description
0 Button does not influence on selected mode
1 Comfort
2 Comfort-1°C
3 Comfort-2°C
4 Eco Mode
5 Frost Protection
6 Stop

The manufacturer defined default value is 4 (Eco Mode).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Input 3 operation mode selection

The following option values may be configured -:

Value Description
0 Button does not influence on selected mode
1 Comfort
2 Comfort-1°C
3 Comfort-2°C
4 Eco Mode
5 Frost Protection
6 Stop

The manufacturer defined default value is 5 (Frost Protection).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 30: Saving the state of the device after a power failure

The following option values may be configured -:

Value Description
0 The module saves its state before power failure
1 The module does not save the state

The manufacturer defined default value is 0 (The module saves its state before power failure).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHJA supports 5 association groups.

Group 1: Lifeline group

Reserved for communication with the main controller This group supports 1 nodes.

Group 2: Multilevel

Triggered at changes of state/value of the Flush pilot wire This group supports 99 nodes.

Group 3: Basic on/off

Triggered at change of the input I1 state and reflecting its state This group supports 99 nodes.

Group 4: Basic on/off

Triggered at change of the input I2 state and reflecting its state This group supports 99 nodes.

Group 5: Basic on/off

Triggered at change of the input I3 state and reflecting its state This group supports 99 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V3| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SENSOR_BINARY_V0| Linked to BASIC|

Endpoint 2

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SENSOR_BINARY_V0| Linked to BASIC|

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SENSOR_BINARY_V0 Linked to BASIC