ZMNHND Flush 1D relay

This describes the Z-Wave device ZMNHND, manufactured by Goap with the thing type UID of qubino_zmnhnd_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

The ZMNHND supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZMNHND -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Binary Sensor sensor_binary Door Switch
Sensor (temperature) sensor_temperature Temperature Number
Switch 1 switch_binary1 Switch Switch
Sensor Binary sensor_binary2 Door Switch
Sensor (temperature) 2 sensor_temperature2 Temperature Number
Burglar alarm_burglar2 Door Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Sensor Binary

Indicates if a sensor has triggered.

The sensor_binary2 channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (temperature) 2

Indicates the current temperature.

The sensor_temperature2 channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Burglar

Indicates if the burglar alarm is triggered.

The alarm_burglar2 channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Device Configuration

The following table provides a summary of the 11 configuration parameters available in the ZMNHND. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Input 1 switch type Input 1 switch type
2 Input 2 contact type Input 2 contact type
10 Activate / deactivate functions ALL ON/ALL OFF Flush 1D relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
11 Automatic turning off relay after set time When relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). 0 - Auto OFF disabled. 1
12 Automatic turning on relay after set time When relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). 0 - Auto ON disabled. 1 –
15 Automatic turning off / on seconds or milliseconds selection NOTE: Parameter is the same for turning OFF or ON.
30 Saving the state of the relay after a power failure Saving the state of the relay after a power failure
63 Output Switch selection Set value means the type of the device that is connected to the output. The device type can be normally open (NO) or normally close (NC).
100 Enable / Disable Endpoints I2 or select Notification Type and Event Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Endpoint device type selec
110 Temperature sensor offset settings Set value is added or subtracted to actual measured value by sensor. 32536 – offset is 0.0C From 1 to 100–value from 0.1°C to 10.0°C is added to actual measured temperature. From 1001 to 1100 – value from -0.1 °C to -10.0 °C is subtracted to actual mea
120 Digital temperature sensor reporting If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. 0 – Reporting disabled 1- 127 = 0,1°C – 12,7°C, step is 0,1°C
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Input 1 switch type

Input 1 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Input 2 contact type

Input 2 contact type

The following option values may be configured -:

Value Description
0 NO (normaly open) input type
1 NC (normaly close) input type

The manufacturer defined default value is 0 (NO (normaly open) input type).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 10: Activate / deactivate functions ALL ON/ALL OFF

Flush 1D relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

The following option values may be configured -:

Value Description
0 ALL ON is not active ALL OFF is not active
1 ALL ON is not active ALL OFF active
2 ALL ON active ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Automatic turning off relay after set time

When relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). 0 - Auto OFF disabled. 1

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: Automatic turning on relay after set time

When relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). 0 - Auto ON disabled. 1 –

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 15: Automatic turning off / on seconds or milliseconds selection

NOTE: Parameter is the same for turning OFF or ON.

The following option values may be configured -:

Value Description
0 Seconds selected
1 Milliseconds selected

The manufacturer defined default value is 0 (Seconds selected).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 30: Saving the state of the relay after a power failure

Saving the state of the relay after a power failure

The following option values may be configured -:

Value Description
0 Flush 1D relay module saves its state before power failure (it returns
1 Flush 1D relay module does not save the state after a power failure, i

The manufacturer defined default value is 0 (Flush 1D relay module saves its state before power failure (it returns).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 63: Output Switch selection

Set value means the type of the device that is connected to the output. The device type can be normally open (NO) or normally close (NC).

The following option values may be configured -:

Value Description
0 When system is turned off the output is 0V (NC).
1 When system is turned off the output is 230V or 24V (NO).

The manufacturer defined default value is 0 (When system is turned off the output is 0V (NC).).

This parameter has the configuration ID config_63_1 and is of type INTEGER.

Parameter 100: Enable / Disable Endpoints I2 or select Notification Type and Event

Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Endpoint device type selec

The following option values may be configured -:

Value Description
0 Endpoint, I2 disabled
1 Home Security; Motion Detection, unknown loc.
2 Carbon Monoxide; Carbon Monoxide detected, unknown location.
3 Carbon Dioxide; Carbon Dioxide detected, unknown location.
4 Water Alarm; Water Leak detected, unknown lo..
5 Heat Alarm; Overheat detected, unknown loc.
6 Smoke Alarm; Smoke detected, unknown loc.
9 Sensor binary.

The manufacturer defined default value is 1 (Home Security; Motion Detection, unknown loc.).

This parameter has the configuration ID config_100_1 and is of type INTEGER.

Parameter 110: Temperature sensor offset settings

Set value is added or subtracted to actual measured value by sensor. 32536 – offset is 0.0C From 1 to 100–value from 0.1°C to 10.0°C is added to actual measured temperature. From 1001 to 1100 – value from -0.1 °C to -10.0 °C is subtracted to actual mea

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 32536.

This parameter has the configuration ID config_110_2 and is of type INTEGER.

Parameter 120: Digital temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. 0 – Reporting disabled 1- 127 = 0,1°C – 12,7°C, step is 0,1°C

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHND supports 6 association groups.

Group 1: Lifeline to Controller (reserved for communication with the main contr

This group supports 1 nodes.

Group 2: Basic on/off (triggered at change of the input Q

state and reflectin

This group supports 16 nodes.

Group 3: Basic on/off (triggered at change of the input I2

state and reflecti

This group supports 16 nodes.

Group 4: Notification report (triggered at change of the input I2

state and r

This group supports 16 nodes.

Group 5: Binary Sensor (triggered at change of the input I2

state and reflect

This group supports 16 nodes.

Group 9: Multilevel Sensor report (triggered at change of temperature sensor)

This group supports 16 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_BINARY_V0| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V7| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| |

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SENSOR_BINARY_V1  
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_ALARM_V5  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3  