ZMNHSD DIN Rail Dimmer

This describes the Z-Wave device ZMNHSD, manufactured by Goap with the thing type UID of qubino_zmnhsd_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZMNHSD product image

The ZMNHSD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

This Z-wave module is used for dimming the bulb or to manage the speed of a fan. The module can be controlled either thorough Z-wave network or through the wall switch.

The module is designed to be mounted inside an electrical cabinet onto DIN rail.

Module measures power consumption of bulb or fan and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.

Inclusion Information

Press service button S for more than 6 seconds or press push button I five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply

Exclusion Information

If service button S is pressed more than 2 and less than 6 seconds (or if push button I is pressed three times within 3s) module is excluded, but configuration parametres are not set to default values.

Note: If the module is included with parameter 5 with value different from default and module reset is done, wait at least 30s before next inclusion

Channels

The following table summarises the channels available for the ZMNHSD -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Dimmer switch_dimmer DimmableLight Dimmer
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 17 configuration parameters available in the ZMNHSD. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Input switch type  
5 Working mode With this parameter it is possible to change the module presentation on the user interface.
10 Activate / deactivate functions ALL ON / ALL OFF DIN dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
11 Automatic turning off output after set time  
12 Automatic turning on output after set time  
21 Enable / Disable Double click function If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value.
30 Saving the state of the device after a power failure If state saving is enabled, DIN dimmer module saves its state before power failure (it returns to the last position saved before a power failure). If state saving is disabled, DIN dimmer module does not save the state after a powe
40 Power reporting in watts on power change Set value means percentage, set value from 0 - 100 = 0% - 100%. Default value is 5. 0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled. Power report is sent (push) only when actual power in Watts in real time changes for more than set p
42 Power reporting in Watts by time interval Set value means time interval (0 – 32767) in seconds, when power report is sent.
60 Minimum dimming value  
61 Maximum dimming value  
65 Dimming time (soft on/off) Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI (BasicSet).
  • default value 100 = 1s
  • 1 - 255 = 100 mseconds – 25500 mseconds (25.5      
      66 Dimming time when key pressed Time to moving the Dimmer between min. and max values (in seconds).
      67 Ignore start level This parameter is used with association group 3. A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. A receiving device MUST ignore the start level if the Ignore Start Level bit is 1.
      68 Dimming duration This parameter is used with association group 3.
      110 Temperature sensor offset settings Set value is added or subtracted to actual measured value by sensor. Available configuration parameters:
  • default value 32536
  • 32536 – offset is 0.0C
  • From 1 to 100 – value from 0.1 °C to 10.0 °C is added to      
      120 Digital temperature sensor reporting If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters:
  • default value 5 = 0.5°C
  • 0 – Reporting disabled      
        Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Input switch type

The following option values may be configured -:

Value Description
0 0 - Mono-stable switch type (push button)
1 1 - Bi-stable switch type

The manufacturer defined default value is 0 (0 - Mono-stable switch type (push button)).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 5: Working mode

With this parameter it is possible to change the module presentation on the user interface.

The following option values may be configured -:

Value Description
0 Dimmer
1 Switch

The manufacturer defined default value is 0 (Dimmer).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 10: Activate / deactivate functions ALL ON / ALL OFF

DIN dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

The following option values may be configured -:

Value Description
0 ALL ON is not active, ALL OFF is not active
1 ALL ON is not active, ALL OFF active
2 ALL ON active, ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Automatic turning off output after set time

  • 0 - Auto OFF disabled
  • 1 – 32536 = 1 second – 32536 seconds Auto OFF enabled with defined time, step is 1 second. The following option values may be configured, in addition to values in the range 0 to 32536 -:
Value Description
0 Auto off DISABLED

The manufacturer defined default value is 0 (Auto off DISABLED).

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: Automatic turning on output after set time

  • 0 - Auto ON disabled
  • 1 – 32536 = 1 second – 32536 seconds Auto ON enabled with defined time, step is 1 second. The following option values may be configured, in addition to values in the range 0 to 32536 -:
Value Description
0 Auto on DISABLED

The manufacturer defined default value is 0 (Auto on DISABLED).

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 21: Enable / Disable Double click function

If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value.

The following option values may be configured -:

Value Description
0 0 - double click disabled
1 1 - double click enabled

The manufacturer defined default value is 0 (0 - double click disabled).

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 30: Saving the state of the device after a power failure

If state saving is enabled, DIN dimmer module saves its state before power failure (it returns to the last position saved before a power failure). If state saving is disabled, DIN dimmer module does not save the state after a powe

The following option values may be configured -:

Value Description
0 0 - Save state enabled
1 1 - Save state disabled

The manufacturer defined default value is 0 (0 - Save state enabled).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 40: Power reporting in watts on power change

Set value means percentage, set value from 0 - 100 = 0% - 100%. Default value is 5. 0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled. Power report is sent (push) only when actual power in Watts in real time changes for more than set p

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 42: Power reporting in Watts by time interval

Set value means time interval (0 – 32767) in seconds, when power report is sent.

  • 0 – reporting disabled
  • 1 – 32767 = 1 second – 32767 seconds. Reporting enabled. Power report is sent with time interval set by entered Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_42_2 and is of type INTEGER.

Parameter 60: Minimum dimming value

  • 1-98 = 1% – 98%, step is 1%. Minimum dimming value is set by entered value.

NOTE: The minimum level may not be higher than the maximum level! 1% min. dimming value is defined by Z- Wave multilevel device class. Values in the range 1 to 98 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_60_1 and is of type INTEGER.

Parameter 61: Maximum dimming value

  • 2-99 = 2% – 99%, step is 1%. Maximum dimming value is set by entered value.

NOTE: The maximum level may not be lower than the minimum level! 99% max. dimming value is defined by Z- Wave multilevel device class. Values in the range 2 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_61_1 and is of type INTEGER.

Parameter 65: Dimming time (soft on/off)

Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI (BasicSet).

  • default value 100 = 1s
  • 1 - 255 = 100 mseconds – 25500 mseconds (25.5

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_65_2 and is of type INTEGER.

Parameter 66: Dimming time when key pressed

Time to moving the Dimmer between min. and max values (in seconds).

  • default value 3 = 3s
  • 1- 255 = 1 second – 255 seconds. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_66_2 and is of type INTEGER.

Parameter 67: Ignore start level

This parameter is used with association group 3. A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. A receiving device MUST ignore the start level if the Ignore Start Level bit is 1.

The following option values may be configured -:

Value Description
0 0 - respect start level
1 1 - ignore start level

The manufacturer defined default value is 0 (0 - respect start level).

This parameter has the configuration ID config_67_1 and is of type INTEGER.

Parameter 68: Dimming duration

This parameter is used with association group 3. The Duration field MUST specify the time that the transition should take from the current value to the new target value. A supporting device SHOULD respect the specified Duration value. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_68_1 and is of type INTEGER.

Parameter 110: Temperature sensor offset settings

Set value is added or subtracted to actual measured value by sensor. Available configuration parameters:

  • default value 32536
  • 32536 – offset is 0.0C
  • From 1 to 100 – value from 0.1 °C to 10.0 °C is added to

Values in the range 1 to 32536 may be set.

The manufacturer defined default value is 32536.

This parameter has the configuration ID config_110_2 and is of type INTEGER.

Parameter 120: Digital temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters:

  • default value 5 = 0.5°C
  • 0 – Reporting disabled

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHSD supports 5 association groups.

Group 1: Controller Updates

This group supports 1 nodes.

Group 2: I1 basic on/off

This group supports 16 nodes.

Group 3: I1 start/stop level change

This group supports 16 nodes.

Group 4: Multilevel set

This group supports 16 nodes.

Group 5: Multilevel sensor report

This group supports 16 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1  
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_METER_V3  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.