ZMNHTD Smart Meter

This describes the Z-Wave device ZMNHTD, manufactured by Goap with the thing type UID of qubino_zmnhtd_00_000.

The device is in the category of Sensor, defining Device used to measure something.

ZMNHTD product image

The ZMNHTD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

This Z-Wave module is used for energy measurements in single-phase electrical power network and can be used in residential, industrial and utility applications. Meters measure energy directly in 2-wire networks according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates energy, power and power factor from the measured signals. The module can be controlled through Z-wave network and it acts as repeater in order to improve range and stability of Z-wave network. It is designed to be mounted on DIN rail.

Measurements: Voltage V Current I Power – Active W Power – Active total Import kWh Power – Active total Export kWh Power – Reactive var Power – Reactive total kvarh Power – Apparent total kVAh Power Factor PF

It is possible to connect two external relay to Smart Meter module. One controlled by built-in optical (IR) communication port on the side, second controlled by output on terminal 5.

Inclusion Information

Module Inclusion (Adding to Z-wave network)

  • Connect module to power supply
  • enable add/remove mode on main controller
  • auto-inclusion (works for about 5 seconds after connected to power supply) or
  • press service button S for more than 2 second

NOTE: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.

Exclusion Information

Module Exclusion/Reset (Removing from Z-Wave network):

  • Connect module to power supply
  • bring module within maximum 1 Meter (3 feet) of the main controller,
  • enable add/remove mode on main controller
  • press service button S for more than 6 seconds.

By this function all parameters of the module are set to default values and own ID is deleted. If service button S is pressed more than 2 and less than 6 seconds module is excluded, but configuration parameters are not set to default values.

Channels

The following table summarises the channels available for the ZMNHTD -:

Channel Channel Id Category Item Type
Power factor meter_powerfactor Energy Number
Voltage meter_voltage Energy Number
Active Power meter_watts Energy Number
Active Energy Comsumption meter_kwh Energy Number
Apparent Energy Consumption meter_kvah Energy Number
Current meter_current Energy Number
Reset Meter Stats meter_reset Energy Switch
switch_binary switch_binary1 Switch Switch
Switch Relay switch_binary2 Switch Switch

Power factor

Indicates the instantaneous power factor.

The meter_powerfactor channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Voltage

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Active Power

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Active Energy Comsumption

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Apparent Energy Consumption

Indicates the energy consumption (kVAh).

The meter_kvah channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Current

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Reset Meter Stats

Reset the meter.

The meter_reset channel supports the Switch item and is in the Energy category.

switch_binary

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Switch Relay

External relay ON

External relay OFF

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 25 configuration parameters available in the ZMNHTD. Detailed information on each parameter can be found in the sections below.

Param Name Description
7 Input 1 switch function selection IR external relay or External Relay control mode
10 Activate / deactivate functions ALL ON / ALL OFF Activate / deactivate functions
11 Timer turning off IR external relay Automatic turning off IR external relay output after set time
12 Timer turning on IR external relay output Automatic turning on IR external relay output after set time
13 Timer turning off External relay output Automatic turning off External relay output after set time
14 Timer turning on External relay after output Automatic turning on External relay after output set time
40 Power reporting (Watts) on power change Power reporting in Watts on power change
42 Power reporting (Watts) by time interval Power reporting in Watts by time interval
45 Reset Power counters Reset Power counters
100 Enable / Disable endpoints relays Enable / Disable endpoints IR external relay and External relay
110 Maximum Power auto off Maximum Power auto off
111 Delay overpower off Delay overpower off
112 Relay to power off Relay to power off
130 Serial Number  
131 Meter Software reference  
132 Meter Hardware reference  
140 Voltage U1  
141 Current I1  
142 Active Power Total (Pt)  
143 Reactive Power Total (Qt)  
144 Power Factor Total (PFt)  
145 Active power accumulated (import)  
146 Reactive power accumulated  
147 Apparent power accumulated  
148 Active power accumulated (export)  
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 7: Input 1 switch function selection

IR external relay or External Relay control mode Available config. parameters (data type is 1 Byte DEC The following option values may be configured -:

Value Description
0 disabled
2 IR external relay control – mono stable push button
3 IR external relay control - bi stable switch
4 External relay control – mono stable push button
5 External relay control – bi stable switch

The manufacturer defined default value is 4 (External relay control – mono stable push button).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 10: Activate / deactivate functions ALL ON / ALL OFF

Activate / deactivate functions Smart Meter module responds to commands ALL ON/ ALL OFF that may be sent by the main controller or by other controller belonging to the system The following option values may be configured -:

Value Description
0 ALL ON is not active, ALL OFF is not active
1 ALL ON is not active, ALL OFF active
2 ALL ON active, ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_3 and is of type INTEGER.

Parameter 11: Timer turning off IR external relay

Automatic turning off IR external relay output after set time When IR external relay is ON it goes automatically OFF after time defined by this Parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). Available configuration parameters (data type is 2 Byte DEC): The following option values may be configured -:

Value Description
0 Auto OFF disabled
32535 Auto OFF enabled with define time, step is 1s

The manufacturer defined default value is 0 (Auto OFF disabled).

This parameter has the configuration ID config_11_2_00007F17 and is of type INTEGER.

Parameter 12: Timer turning on IR external relay output

Automatic turning on IR external relay output after set time When IR external relay is OFF it goes automatically ON after time defined by this Parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). Available configuration parameters (data type is 2 Byte DEC) Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 13: Timer turning off External relay output

Automatic turning off External relay output after set time When External relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). Available configuration parameters (data type is 2 Byte DEC) Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_13_2 and is of type INTEGER.

Parameter 14: Timer turning on External relay after output

Automatic turning on External relay after output set time When External relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). Available configuration parameters (data type is 2 Byte DEC) Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_14_2 and is of type INTEGER.

Parameter 40: Power reporting (Watts) on power change

Power reporting in Watts on power change Set value means percentage, set value from 0 – 100 = 0% - 100%. Available configuration parameters (data type is 1 Byte DEC)

Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%

NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. When reporting Watts, module will automatically reports also V (Voltage), A (Amperes), Power factor, kVar (Reactive Power). Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_40_2 and is of type INTEGER.

Parameter 42: Power reporting (Watts) by time interval

Power reporting in Watts by time interval Set value means time interval (0 – 32535) in seconds, when power report is send. Available config. parameters (data type is 2 Byte DEC).

Power report is send with time interval set by entered value. When reporting Watts, module will automatically reports also V (Voltage), A (Amperes), Power factor, kVar (Reactive Power) Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_42_2 and is of type INTEGER.

Parameter 45: Reset Power counters

Reset Power counters Available config. parameters (data type is 1 Byte DEC The following option values may be configured -:

Value Description
0 No function
1 reset counter 1 – KWh
2 reset counter 2 – kVARh
4 reset counter 3 – kVAh
15 reset ALL counters

The manufacturer defined default value is 0 (No function).

This parameter has the configuration ID config_45_1 and is of type INTEGER.

Parameter 100: Enable / Disable endpoints relays

Enable / Disable endpoints IR external relay and External relay Enabling IR external relay and External relay or both of them, means that endpoint (IR external relay) and endpoint (External relay) or both will be present on UI. Disabling them will result in hiding endpoints according to Parameter set value. Note that hiding endpoint has no impact on its functionality. Available configuration parameters (data type is 1 Byte DEC)

NOTE1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module. NOTE 2: If you don’t have IR BiComm relay module mounted and you enable IR communication (parameter 100 is 2 or 3) there will be no valid IR relay state reported. It will be reported IR COMMUNICATION ERROR and LED2 will BLINK The following option values may be configured -:

Value Description
0 Endpoints IR external relay and External relay disabled
1 Endpoints IR external relay disabled, External relay enabled
2 Endpoints IR external relay enabled, External relay disabled
3 Endpoints IR external relay and External relay enabled

The manufacturer defined default value is 0 (Endpoints IR external relay and External relay disabled).

This parameter has the configuration ID config_100_1 and is of type INTEGER.

Parameter 110: Maximum Power auto off

Maximum Power auto off Set value means Maximum Power Consumption (0 - 15000) in watts (W), when relays are turned off according to parameters no. 111 and 112. Available configuration parameters (data type is 2 Bytes DEC The following option values may be configured -:

Value Description
0 No function
15000 Maximum Power Consumption

The manufacturer defined default value is 0 (No function).

This parameter has the configuration ID config_110_2 and is of type INTEGER.

Parameter 111: Delay overpower off

Delay overpower off Set value means number of second to power off relay (defined by parameters no. 110 and 112) before restart (30 - 32535) in seconds (s). Available configuration parameters (data type is 2 Bytes DEC): Values in the range 0 to 32525 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_111_2 and is of type INTEGER.

Parameter 112: Relay to power off

Relay to power off Set value selects relay to be powered off when threshold is reached (defined by parameters no. 110 and 111). Available config. parameters (data type is 1 Byte DEC) The following option values may be configured -:

Value Description
0 switch between the 2 relays
1 always power off relay 1 (IR external relay)
2 always power off relay 2 (External relay)
3 always power off both relays (relay 1 and relay 2)

The manufacturer defined default value is 0 (switch between the 2 relays).

This parameter has the configuration ID config_112_1 and is of type INTEGER.

Parameter 130: Serial Number

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_130_32 and is of type INTEGER. This is a read only parameter.

Parameter 131: Meter Software reference

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_131_16 and is of type INTEGER. This is a read only parameter.

Parameter 132: Meter Hardware reference

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_132_16 and is of type INTEGER. This is a read only parameter.

Parameter 140: Voltage U1

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_140_24 and is of type INTEGER. This is a read only parameter.

Parameter 141: Current I1

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_141_24 and is of type INTEGER. This is a read only parameter.

Parameter 142: Active Power Total (Pt)

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_142_24 and is of type INTEGER. This is a read only parameter.

Parameter 143: Reactive Power Total (Qt)

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_143_24 and is of type INTEGER. This is a read only parameter.

Parameter 144: Power Factor Total (PFt)

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_144_16 and is of type INTEGER. This is a read only parameter.

Parameter 145: Active power accumulated (import)

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_145_32 and is of type INTEGER. This is a read only parameter.

Parameter 146: Reactive power accumulated

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_146_32 and is of type INTEGER. This is a read only parameter.

Parameter 147: Apparent power accumulated

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_147_32 and is of type INTEGER. This is a read only parameter.

Parameter 148: Active power accumulated (export)

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_148_32 and is of type INTEGER. This is a read only parameter.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHTD supports 1 association group.

Group 1: Lifeline

Reserved for communication with the main controller This group supports 1 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V2| | | COMMAND_CLASS_SWITCH_ALL_V0| | | COMMAND_CLASS_METER_V4| | | COMMAND_CLASS_CRC_16_ENCAP_V0| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V0| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2| | | COMMAND_CLASS_MULTI_CHANNEL_V4| | | COMMAND_CLASS_CONFIGURATION_V0| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2| | | COMMAND_CLASS_POWERLEVEL_V0| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | | COMMAND_CLASS_MARK_V0| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V2| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | | COMMAND_CLASS_MARK_V0| |

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_BINARY_V2 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2  
COMMAND_CLASS_ZWAVEPLUS_INFO_V2  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3  
COMMAND_CLASS_MARK_V0  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.