ZMNHAA Flush 1 relay

This describes the Z-Wave device ZMNHAA, manufactured by Goap with the thing type UID of qubino_zmnhaa_00_000.

Flush 1 relay

Channels

The following table summarises the channels available for the ZMNHAA Flush 1 relay.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Binary Sensor 1 sensor_binary1 sensor_binary Door Switch
Binary Sensor 2 sensor_binary2 sensor_binary Door Switch

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHAA Flush 1 relay. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type Input 1 switch type
2: Input 2 contact type Input 2 contact type
3: Input 3 contact type Input 3 contact type
10: Activate / deactivate functions ALL ON/ALL OFF Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main co…
11: Automatic turning off relay after set time 0 - Auto OFF disabled 1 – 65535 = 0,01second – 655,35 seconds Auto OFF enabled with define…
30: Saving the state of the relay after a power failure Saving the state of the relay after a power failure
40: Power reporting in Watts on power change 0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled Power report is send (push) o…
42: Power reporting in Watts on power change default value 300 (power report in Watts is send each 300s) 0 – Reporting Disabled 1 – 655…
1: basic on/off (triggered at change of the output Q state and reflecti  
2: basic on/off (triggered at change of the input I2 state and reflect  
3: basic on/off (triggered at change of the input I3 state and reflect  
4: Controller Updates  

1: Input 1 switch type

Input 1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

2: Input 2 contact type

Input 2 contact type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options NO (normaly open) input type (0)      
  NC (normaly close) input type (1)      

3: Input 3 contact type

Input 3 contact type

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options NO (normaly open) input type (0)      
  NC (normaly close) input type (1)      

10: Activate / deactivate functions ALL ON/ALL OFF

Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 255
Options ALL ON is not active ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

11: Automatic turning off relay after set time

0 - Auto OFF disabled 1 – 65535 = 0,01second – 655,35 seconds Auto OFF enabled with define time, step is 10mseconds

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

30: Saving the state of the relay after a power failure

Saving the state of the relay after a power failure

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options Flush 1relay module saves its state before power failure (it returns t (0)      
  Flush 1relay module does not save the state after a power failure, it (1)      

40: Power reporting in Watts on power change

0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power chan

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 255
Default Value 3

42: Power reporting in Watts on power change

default value 300 (power report in Watts is send each 300s) 0 – Reporting Disabled 1 – 65535 = 1second – 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value.

Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 65535
Default Value 300

1: basic on/off (triggered at change of the output Q state and reflecti

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: basic on/off (triggered at change of the input I2 state and reflect

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: basic on/off (triggered at change of the input I3 state and reflect

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Controller Updates

Property Value
Configuration ID group_4
Data Type TEXT
Range to