ZMNHAD Flush 1 relay

This describes the Z-Wave device ZMNHAD, manufactured by Goap with the thing type UID of qubino_zmnhad_00_000.

Flush 1 relay

Overview

This Z-Wave module is used for switching on or off the electrical device (e.g. light or fan). The module can be controlled either through Z-wave network or through the wall switch. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of electrical device and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network. Supported switches Module supports mono-stable switches (push button) and bi-stable switches. The module is factory set to operate with bi-stable switches.

Inclusion Information

Module Inclusion (Adding to Z-Wave network)

  • Connect module to power supply (with temperature sensor connected -if purchased)
  • Enable add/remove mode on main controller
  • Auto-inclusion (works forabout 5 seconds after connected to power supply) or
  • Press push button I1 three times within 3s (3 times change switch state within 3 seconds) or
  • Press service button S (only applicable for 24 V SELV supply voltage) for more than 2 seconds.

NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.

NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply , connect the sensor and re-include the module.

Exclusion Information

Module Exclusion/Reset (Removing from Z-Wavenetwork)

  • Connect module to power supply
  • Bring module within maximum 1 meter (3 feet) of the main controller,
  • Enable add/remove mode on main controller,
  • Press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
  • Press service button (only applicable for 24 V SELV supply voltage) for more than 6 seconds.

By this function all parameters of the module are set to default values and own ID is deleted.

If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.

Channels

The following table summarises the channels available for the ZMNHAD Flush 1 relay.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Binary Sensor sensor_binary sensor_binary Door Switch
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Alarm (power) alarm_power alarm_power Door Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Binary Sensor I2 sensor_binary2 sensor_binary Door Switch
Alarm (power) 2 alarm_power2 alarm_power Door Switch
Binary Sensor I3 sensor_binary3 sensor_binary Door Switch
Sensor (temperature) sensor_temperature3 sensor_temperature Temperature Number
Sensor (temperature) sensor_temperature4 sensor_temperature Temperature Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHAD Flush 1 relay. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type Input 1 switch type
2: Input 2 contact type Input 2 contact type
3: Input 3 contact type Input 3 contact type
10: Activate / deactivate functions ALL ON/ALL OFF Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main co…
11: Automatic turning off relay after set time When relay is ON it goes automatically OFF after time defined by this parameter. Timer is …
12: Automatic turning on relay after set time When relay is OFF it goes automatically ON after time defined by this parameter. Timer is …
15: Automatic turning off / on seconds or milliseconds selection NOTE: Parameter is the same for turning OFF or ON.
30: Saving the state of the relay after a power failure Saving the state of the relay after a power failure
40: Power reporting in Watts on power change 0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled Power report is send (push) o…
42: Power reporting in Watts on power change Set value means time interval (0 – 32535) in seconds, when power report is send. Default v…
63: Output Switch selection Set value means the type of the device that is connected to the output. The device type ca…
100: Enable / Disable Endpoints I2 or select Notification Type and Event Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hi…
101: Enable / Disable Endpoints I3 or select Notification Type and Event Enabling I3 means that Endpoint (I3) will be present on UI. Disabling it will result in hi…
110: Temperature sensor offset settings Set value is added or subtracted to actual measured value by sensor. 32536 – offset is 0.0…
120: Digital temperature sensor reporting If digital temperature sensor is connected, module reports measured temperature on tempera…
1: Lifeline Lifeline group (reserved for communication with the main controller
2: Basic on/off (triggered at change of the input Q state and reflectin  
3: Basic on/off (triggered at change of the input I2 state and reflecti  
4: Notification report (triggered at change of the input I2 state and r  
5: Binary Sensor (triggered at change of the input I2 state and reflect  
6: Basic on/off (triggered at change of the input I3 state and reflecti  
7: Notification report (triggered at change of the input I3 state and re  
8: Binary Sensor report(triggered at change of the input I3 state and r  
9: Multilevel Sensor report (triggered at change of temperature sensor)  

1: Input 1 switch type

Input 1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

2: Input 2 contact type

Input 2 contact type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options NO (normaly open) input type (0)      
  NC (normaly close) input type (1)      

3: Input 3 contact type

Input 3 contact type

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options NO (normaly open) input type (0)      
  NC (normaly close) input type (1)      

10: Activate / deactivate functions ALL ON/ALL OFF

Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 255
Options ALL ON is not active ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

11: Automatic turning off relay after set time

When relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). 0 - Auto OFF disabled. 1

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

12: Automatic turning on relay after set time

When relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). 0 - Auto ON disabled. 1 –

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

15: Automatic turning off / on seconds or milliseconds selection

NOTE: Parameter is the same for turning OFF or ON.

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options Seconds selected (0)      
  Milliseconds selected (1)      

30: Saving the state of the relay after a power failure

Saving the state of the relay after a power failure

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options Flush 1relay module saves its state before power failure (it returns t (0)      
  Flush 1relay module does not save the state after a power failure, it (1)      

40: Power reporting in Watts on power change

0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: If power chan

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 255
Default Value 10

42: Power reporting in Watts on power change

Set value means time interval (0 – 32535) in seconds, when power report is send. Default value 300 (power report in Watts is send each 300s) 0 – Reporting Disabled 1 – 32535 = 1second – 32535 seconds. Reporting enabled. Power report is send with time

Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 65535
Default Value 300

63: Output Switch selection

Set value means the type of the device that is connected to the output. The device type can be normally open (NO) or normally close (NC).

Property Value      
Configuration ID config_63_1      
Data Type INTEGER   Default Value 0
Options When system is turned off the output is 0V (NC). (0)      
  When system is turned off the output is 230V or 24V (NO). (1)      

100: Enable / Disable Endpoints I2 or select Notification Type and Event

Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Endpoint device type selec

Property Value      
Configuration ID config_100_1      
Data Type INTEGER   Default Value 1
Options Endpoint, I2 disabled (0)      
  Home Security; Motion Detection, unknown loc. (1)      
  Carbon Monoxide; Carbon Monoxide detected, unknown location. (2)      
  Carbon Dioxide; Carbon Dioxide detected, unknown location. (3)      
  Water Alarm; Water Leak detected, unknown lo.. (4)      
  Heat Alarm; Overheat detected, unknown loc. (5)      
  Smoke Alarm; Smoke detected, unknown loc. (6)      
  Sensor binary. (9)      

101: Enable / Disable Endpoints I3 or select Notification Type and Event

Enabling I3 means that Endpoint (I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Endpoint device type selec

Property Value      
Configuration ID config_101_1      
Data Type INTEGER   Default Value 1
Options Endpoint, I3 disabled (0)      
  Home Security; Motion Detection, unknown loc. (1)      
  Carbon Monoxide; Carbon Monoxide detected, unknown location. (2)      
  Carbon Dioxide; Carbon Dioxide detected, unknown location. (3)      
  Water Alarm; Water Leak detected, unknown lo.. (4)      
  Heat Alarm; Overheat detected, unknown loc. (5)      
  Smoke Alarm; Smoke detected, unknown loc. (6)      
  Sensor binary. (9)      

110: Temperature sensor offset settings

Set value is added or subtracted to actual measured value by sensor. 32536 – offset is 0.0C From 1 to 100–value from 0.1°C to 10.0°C is added to actual measured temperature. From 1001 to 1100 – value from -0.1 °C to -10.0 °C is subtracted to actual mea

Property Value
Configuration ID config_110_2
Data Type INTEGER
Range 0 to 65535
Default Value 32536

120: Digital temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.0 – Reporting disabled1- 127 = 0,1°C – 12,7°C, step is 0,1°C

Property Value
Configuration ID config_120_1
Data Type INTEGER
Range 0 to 127
Default Value 5

1: Lifeline

Lifeline group (reserved for communication with the main controller

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic on/off (triggered at change of the input Q state and reflectin

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Basic on/off (triggered at change of the input I2 state and reflecti

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Notification report (triggered at change of the input I2 state and r

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Binary Sensor (triggered at change of the input I2 state and reflect

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: Basic on/off (triggered at change of the input I3 state and reflecti

Property Value
Configuration ID group_6
Data Type TEXT
Range to

7: Notification report (triggered at change of the input I3 state and re

Property Value
Configuration ID group_7
Data Type TEXT
Range to

8: Binary Sensor report(triggered at change of the input I3 state and r

Property Value
Configuration ID group_8
Data Type TEXT
Range to

9: Multilevel Sensor report (triggered at change of temperature sensor)

Property Value
Configuration ID group_9
Data Type TEXT
Range to