ZMNHBA Flush 2 relays

This describes the Z-Wave device ZMNHBA, manufactured by Goap with the thing type UID of qubino_zmnhba_00_000.

Flush 2 relays

Channels

The following table summarises the channels available for the ZMNHBA Flush 2 relays.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHBA Flush 2 relays. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type Input 1 switch type
2: Input 2 switch type Input 2 switch type
10: Activate / deactivate functions ALL ON/ALL OFF Activate / deactivate functions ALL ON/ALL OFF
11: Automatic turning off relay Q1 after set time Automatic turning off relay Q1 after set time
12: Automatic turning off relay Q2 after set time Automatic turning off relay Q2 after set time
30: Saving Q1 and Q2 after a power failure Saving the state of the relays Q1 and Q2 after a power failure
40: Power reporting in Watts on power change for Q1 Power report is sent (pushed) only when actual power in Watts in real time changed for mor…
41: Power reporting in Watts on power change for Q2 Power report is sent (pushed) only when actual power in Watts in real time changed for mor…
42: Power reporting in Watts by time interval for Q1 default value is 300 (power report in Watts is sent each 300s)
43: Power reporting in Watts by time interval for Q2 default value is 300 (power report in Watts is sent each 300s)
1: Basic on/off Q1  
2: Basic on/off Q2  
3: Default Reporting Group  

1: Input 1 switch type

Input 1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

2: Input 2 switch type

Input 2 switch type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

10: Activate / deactivate functions ALL ON/ALL OFF

Activate / deactivate functions ALL ON/ALL OFF

Overview

Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 255
Options ALL ON is not active ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

11: Automatic turning off relay Q1 after set time

Automatic turning off relay Q1 after set time

Overview

Auto OFF enabled with define time, step is 10 mseconds

  • 0 = Auto OFF disabled
  • 1–65535 = 0,01 second – 655,35 seconds
Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

12: Automatic turning off relay Q2 after set time

Automatic turning off relay Q2 after set time

Overview

Auto OFF enabled with define time, step is 10 mseconds

  • 0 = Auto OFF disabled
  • 1–65535 = 0,01 second – 655,35 seconds
Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

30: Saving Q1 and Q2 after a power failure

Saving the state of the relays Q1 and Q2 after a power failure

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options Flush 2 relays module saves its state before power failure (it returns (0)      
  Flush 2 relays module does not save the state after a power failure, i (1)      

40: Power reporting in Watts on power change for Q1

Power report is sent (pushed) only when actual power in Watts in real time changed for more than set percentage comparing to previous actual power in Watts, step is 1%.

  • 0 = Reporting Disabled
  • 1–100 = 1% - 100% Reporti
Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 255
Default Value 1

41: Power reporting in Watts on power change for Q2

Power report is sent (pushed) only when actual power in Watts in real time changed for more than set percentage comparing to previous actual power in Watts, step is 1%.

  • 0 = Reporting Disabled
  • 1–100 = 1% - 100% Reporti
Property Value
Configuration ID config_41_1
Data Type INTEGER
Range 0 to 255
Default Value 1

42: Power reporting in Watts by time interval for Q1

default value is 300 (power report in Watts is sent each 300s)

  • 0 = Reporting Disabled
  • 1–65535 = 1 second – 65535 seconds. Reporting enabled. Power report is sent with time interval set by entered value.
Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 65535
Default Value 300

43: Power reporting in Watts by time interval for Q2

default value is 300 (power report in Watts is sent each 300s)

  • 0 = Reporting Disabled
  • 1–65535 = 1 second – 65535 seconds. Reporting enabled. Power report is sent with time interval set by entered value.
Property Value
Configuration ID config_43_2
Data Type INTEGER
Range 0 to 65535
Default Value 300

1: Basic on/off Q1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic on/off Q2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Default Reporting Group

Property Value
Configuration ID group_3
Data Type TEXT
Range to