ZMNHBD Flush 2 relays

This describes the Z-Wave device ZMNHBD, manufactured by Goap with the thing type UID of qubino_zmnhbd_00_000.

Flush 2 relays

Overview

This Z-Wave module is used for switching on or off two electrical devices (e.g. lights or fans,..). The module can be controlled either through Z-Wave network or through the wallswitches. The module is designed to be mounted inside a “flush mountingbox”, hidden behind a traditional wall switch. Module measures power consumption of two electrical devices and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.

Inclusion Information

Module Inclusion (Adding to Z-Wave network)

  • Connect module to power supply (with temperature sensor connected -if purchased)
  • Enable add/remove mode on main controller
  • Auto-inclusion (works forabout 5 seconds after connected to power supply) or
  • Press push button I1 three times within 3s (3 times change switch state within 3 seconds) or
  • Press service button S (only applicable for 24 V SELV supply voltage) for more than 2 seconds.

NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.

NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply , connect the sensor and re-include the module.

Exclusion Information

Module Exclusion/Reset (Removing from Z-Wavenetwork)

  • Connect module to power supply
  • Bring module within maximum 1 meter (3 feet) of the main controller,
  • Enable add/remove mode on main controller,
  • Press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
  • Press service button S (only applicable for 24 V SELV supply voltage) for more than 6 seconds.

By this function all parameters of the module are set to default values and own ID is deleted.

If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.

Channels

The following table summarises the channels available for the ZMNHBD Flush 2 relays.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Sensor (temperature) sensor_temperature3 sensor_temperature Temperature Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHBD Flush 2 relays. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type Input 1 switch type
2: Input 2 switch type Input 2 switch type
10: Functions ALL ON/ALL OFF Activate / deactivate functions ALL ON/ALL OFF
11: Automatic turning off output Q1 after set time When relay Q1 is ON it goes automatically OFF after defined time
12: Automatic turning on output Q1 after set time When relay Q1 is OFF it goes automatically ON after defined time
13: Automatic turning off relay Q2 after set time When relay Q2 is ON it goes automatically OFF after defined time
14: Automatic turning on output Q2 after set time When relay Q2 is OFF it goes automatically ON after defined time
15: Automatic turning off / on seconds or milliseconds selection Automatic turning off / on seconds or milliseconds selection
30: Saving the state after a power failure Saving the state of the relays Q1 and Q2 after a power failure
40: Power reporting in Watts for Q1 Power reporting in Watts on power change for Q1
41: Power reporting in Watts for Q2 Power reporting in Watts on power change for Q2
42: Power reporting time interval for Q1 Power reporting in Watts by time interval for Q1
43: Power reporting time interval for Q2 Power reporting in Watts by time interval for Q2
63: Output Q1 Switch selection  
64: Output Q2 Switch selection  
110: Temperature sensor offset Temperature sensor offset settings
120: Digital temperature sensor reporting Digital temperature sensor reporting
1: Default Reporting Group  
2: Q1 basic on/off  
3: Q1 switch binary  
4: Q1 power meter  
5: Q2 basic on/off  
6: Q2 switch binary  
7: Q2 power meter  
8: Multilevel sensor  

1: Input 1 switch type

Input 1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

2: Input 2 switch type

Input 2 switch type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

10: Functions ALL ON/ALL OFF

Activate / deactivate functions ALL ON/ALL OFF

Overview

Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_2      
Data Type INTEGER   Default Value 255
Options ALL ON is not active ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

11: Automatic turning off output Q1 after set time

When relay Q1 is ON it goes automatically OFF after defined time

Overview

Timer is reset to zero each time the module receive ON command regardless from where it comes  (push button, associated module, controller,..).

  • 0 - Auto OFF disabled
  • 1 - 32535 = 1second (0,01s) - 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15.
Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 32535
Default Value 0

12: Automatic turning on output Q1 after set time

When relay Q1 is OFF it goes automatically ON after defined time

Overview

Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..).

  • 0 - Auto ON disabled
  • 1 - 32535 = 1second (0,01s) - 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15.
Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 32535
Default Value 0

13: Automatic turning off relay Q2 after set time

When relay Q2 is ON it goes automatically OFF after defined time

Overview

Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..).

  • 0 -Auto OFF disabled
  • 1 - 32535 = 1second (0,01s) - 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15.
Property Value
Configuration ID config_13_2
Data Type INTEGER
Range 0 to 32535
Default Value 0

14: Automatic turning on output Q2 after set time

When relay Q2 is OFF it goes automatically ON after defined time

Overview

Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..).

  • 0 -Auto ON disabled
  • 1 - 32535 = 1second (0,01s) - 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15.
Property Value
Configuration ID config_14_2
Data Type INTEGER
Range 0 to 32535
Default Value 0

15: Automatic turning off / on seconds or milliseconds selection

Automatic turning off / on seconds or milliseconds selection

Overview

Available configuration parameters:

  • 0 – seconds selected
  • 1 – milliseconds selected

NOTE: Parameter is valid for both outputs Q1, Q2 and is the same for turning off or on.

Property Value
Configuration ID config_15_1
Data Type INTEGER
Range 0 to 255
Default Value 0

30: Saving the state after a power failure

Saving the state of the relays Q1 and Q2 after a power failure

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options Saves its state before power failure (0)      
  Does not save the state after a power failure (1)      

40: Power reporting in Watts for Q1

Power reporting in Watts on power change for Q1

Overview

Set value means percentage, set value from 0 –100 = 0% -100%.

Available configuration parameters:

  • 0 - reporting disabled
  • 1 -100 = 1% -100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

NOTE: If power changed is less than 1W, the report is not send (pushed), independent of percentage set.

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 100
Default Value 10

41: Power reporting in Watts for Q2

Power reporting in Watts on power change for Q2

Overview

Set value means percentage, set value from 0 –100 = 0% -100%. Available configuration parameters:

  • 0 - reporting disabled
  • 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

NOTE: If power changed is less than 1W, the report is not send (pushed), independent of percentage set.

Property Value
Configuration ID config_41_1
Data Type INTEGER
Range 0 to 100
Default Value 10

42: Power reporting time interval for Q1

Power reporting in Watts by time interval for Q1

Overview

Set value means time interval (0 – 32535) in seconds, when power report is send. Available configuration parameters:

  • Default value 300 (power report in Watts is send each 300s)
  • 0 - reporting disabled
  • 1 - 32535 = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value.
Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 32535
Default Value 300

43: Power reporting time interval for Q2

Power reporting in Watts by time interval for Q2

Overview

Set value means time interval (0 –32535) in seconds, when power report is send. Available configuration parameters:

  • Default value 300 (power report in Watts is send each 300s)
  • 0 - reporting disabled
  • 1 - 32535 = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value.
Property Value
Configuration ID config_43_2
Data Type INTEGER
Range 0 to 32535
Default Value 300

63: Output Q1 Switch selection

Property Value      
Configuration ID config_63_1      
Data Type INTEGER   Default Value 0
Options When system is turned off the output is 0V (NC) (0)      
  When system is turned off the output is 230V or 24V (NO) (1)      

64: Output Q2 Switch selection

Property Value      
Configuration ID config_64_1      
Data Type INTEGER   Default Value 0
Options When system is turned off the output is 0V (NC) (0)      
  When system is turned off the output is 230V or 24V (NO) (1)      

110: Temperature sensor offset

Temperature sensor offset settings

Overview

Set value is added or subtracted to actual measured value by sensor. Available configuration parameters:

  • Default value 32536
  • 32536 - offset is 0.0C
  • From 1 to 100 - value from 0.1 °C to 10.0 °C is added to actual measured temperature.
  • From 1001 to 1100 -value from -0.1 °C to -10.0 °C is subtracted to actual measured temperature.
Property Value
Configuration ID config_110_2
Data Type INTEGER
Range 0 to 32536
Default Value 32536

120: Digital temperature sensor reporting

Digital temperature sensor reporting

Overview

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters:

  • Default value 5 = 0,5°C
  • 0 – Reporting disabled
  • 1 - 127 = 0,1°C – 12,7°C, step is 0,1°C
Property Value
Configuration ID config_120_1
Data Type INTEGER
Range 0 to 127
Default Value 5

1: Default Reporting Group

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Q1 basic on/off

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Q1 switch binary

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Q1 power meter

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Q2 basic on/off

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: Q2 switch binary

Property Value
Configuration ID group_6
Data Type TEXT
Range to

7: Q2 power meter

Property Value
Configuration ID group_7
Data Type TEXT
Range to

8: Multilevel sensor

Property Value
Configuration ID group_8
Data Type TEXT
Range to