ZMNHDA Flush dimmer

This describes the Z-Wave device ZMNHDA, manufactured by Goap with the thing type UID of qubino_zmnhda_00_000.

Flush dimmer

Channels

The following table summarises the channels available for the ZMNHDA Flush dimmer.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Binary Sensor 1 sensor_binary1 sensor_binary Door Switch
Binary Sensor 2 sensor_binary2 sensor_binary Door Switch

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHDA Flush dimmer. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type Switch type (input I1)
2: Input 2 contact type Input 2 contact type
3: Input 3 contact type Input 3 contact type
10: Activate / deactivate functions ALL ON/ALL OFF Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main co…
30: Saving the state of the device after a power failure Saving the state of the device after a power failure
40: Power reporting in Watts on power change for Q1 Set value means percentage, set value from 0-100 = 0%-100%. Power report is sent (pushed) …
42: Power reporting in Watts by time interval Set value means time interval (0 – 65535) in seconds, when power report is sent. Default v…
60: Minimum dimming value Range is 1% – 98%, step is 1%.
61: Maximum dimming value Range is 2% – 99%, step is 1%.
65: Dimming time (soft on/off) Set value means time of moving the Dimmer between min. and max. dimming values by short pr…
66: Dimming time when key pressed Time of moving the Dimmer between min. and max dimming values by continues hold of push bu…
1: multilevel (triggered at changes of state/value of the Flush dimmer)  
2: basic on/off (triggered at change of the input I2 state and reflecting  
3: basic on/off (triggered at change of the input I3 state and reflecting  
4: Controller updates  

1: Input 1 switch type

Switch type (input I1)

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options mono-stable switch (push button) (0)      
  bi-stable (toggle) switch (1)      

2: Input 2 contact type

Input 2 contact type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

3: Input 3 contact type

Input 3 contact type

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

10: Activate / deactivate functions ALL ON/ALL OFF

Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 255
Options ALL ON is not active ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

30: Saving the state of the device after a power failure

Saving the state of the device after a power failure

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options Flush dimmer module saves its state before power failure (it returns t (0)      
  Flush dimmer module does not save the state after a power failure, it (1)      

40: Power reporting in Watts on power change for Q1

Set value means percentage, set value from 0-100 = 0%-100%. Power report is sent (pushed) only when actual power in Watts in real time changed for more than set percentage comparing to previous actual power in Watts, step is 1%.

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 255
Default Value 5

42: Power reporting in Watts by time interval

Set value means time interval (0 – 65535) in seconds, when power report is sent. Default value is 300 (power report in Watts is sent each 300s)

  • 0 = Reporting Disabled
  • 1–65535 = 1 second – 65535 seconds. Reporting enab
Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 65535
Default Value 300

60: Minimum dimming value

Range is 1% – 98%, step is 1%.
Default value is 1 (Minimum dimming value is 1%)
NOTE: The maximum level may not be lower than the minimum level!
1% min. dimming value is defined by Z-Wave multilevel device class.

Property Value
Configuration ID config_60_1
Data Type INTEGER
Range 0 to 255
Default Value 1

61: Maximum dimming value

Range is 2% – 99%, step is 1%.
Default value 99 (Maximum dimming value is 99 %)
NOTE: The maximum level may not be lower than the minimum level!
99% max. dimming value is defined by Z-Wave multilevel device class.

Property Value
Configuration ID config_61_1
Data Type INTEGER
Range 0 to 255
Default Value 99

65: Dimming time (soft on/off)

Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI.
Range is 1-255 = 10-2550ms (2.55s), step is 10ms.
Default value 100 (Dimming time between m

Property Value
Configuration ID config_65_1
Data Type INTEGER
Range 0 to 255
Default Value 100

66: Dimming time when key pressed

Time of moving the Dimmer between min. and max dimming values by continues hold of push button I1.
Range is 1-255 = 1-255s, step is 1s.
Default value 3 (Dimming time between min. and max. dimming values is 3s)

Property Value
Configuration ID config_66_1
Data Type INTEGER
Range 0 to 255
Default Value 3

1: multilevel (triggered at changes of state/value of the Flush dimmer)

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: basic on/off (triggered at change of the input I2 state and reflecting

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: basic on/off (triggered at change of the input I3 state and reflecting

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Controller updates

Property Value
Configuration ID group_4
Data Type TEXT
Range to