ZMNHDD Flush Dimmer Plus

This describes the Z-Wave device ZMNHDD, manufactured by Goap with the thing type UID of qubino_zmnhdd_00_000.

Flush Dimmer Plus

Overview

This Z-Wave module is used for dimming the bulb or to manage the speed of a fan. The module can be controlled either through a Z-Wave network or through the wall switch. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of bulb or fan and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.

Inclusion Information

WARNING: Service button S must NOT be used when module is connected to 110-230V power supply.

  • Connect module to power supply (with temperature sensor connected - if purchased),
  • Enable add/remove mode on main controller
  • Auto-inclusion (works for about 2 minutesafter connected to power supply) or
  • 110V-230V power supply: Press push button I1 three times within 3 seconds (3 times change switch state within 3 seconds)
  • 24V SELV: Press service button S for more than 2 seconds.

NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.

NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply,connect the sensor and re-include the module.

Exclusion Information

WARNING: Service button S must NOT be used when module is connected to 110-230V power supply.

  • Connect module to power supply
  • Bring module within maximum 1 meter (3 feet) of the main controller
  • Enable add/remove mode on main controller
  • 110V-230V power supply: Press push button I1 five times within 3 seconds (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply
  • 24V SELV: Press ervice button S for more than 6 seconds.

By this function all parameters of the module are set to default values and own ID is deleted. If push button I1 is pressed three times within 3 seconds (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.

NOTE: If the module is included with parameters 100 or 101 with values different to default and module reset is done, wait at least 30s before next inclusion.

Channels

The following table summarises the channels available for the ZMNHDD Flush Dimmer Plus.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Reset the total power consumption meter_reset meter_reset Energy Switch
Alarm alarm_general alarm_general Door Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Dimmer 1 switch_dimmer1 switch_dimmer DimmableLight Dimmer
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Binary Sensor 2 sensor_binary2 sensor_binary Door Switch
Alarm 2 alarm_general2 alarm_general Door Switch
Binary Sensor 3 sensor_binary3 sensor_binary Door Switch
Alarm 3 alarm_general3 alarm_general Door Switch

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Dimmer 1

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHDD Flush Dimmer Plus. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type  
2: Input 2 switch type  
3: Input 2 contact type  
4: Input 3 contact type  
10: Activate / deactivate functions ALL ON / ALL OFF Flush dimmer module responds to commands ALL ON / ALL OFF
11: Automatic turning off output after set time Auto OFF enabled with defined time, step is 1 second.
12: Automatic turning on output after set time Auto ON enabled with defined time, step is 1 second.
20: Enable / Disable 3-way switch Dimming is done by push button or switch connected to I1.
21: Enable / Disable Double click function A fast double click on the push button will set dimming power at maximum.
30: Saving the state of the device after a power failure If enabled, flush dimmer module saves its state before power failure.
40: Power reporting in watts on power change Set value is percentage, set value from 0 - 100 = 0% - 100%.
42: Power reporting in Watts by time interval Set value means time interval (0 – 32767) in seconds.
60: Minimum dimming value Minimum dimming value is set by entered value.
61: Maximum dimming value Maximum dimming value is set by entered value.
65: Dimming time (soft on/off) Set value means time of moving the Dimmer between min. and max. dimming values
66: Dimming time when key pressed Time of moving the Dimmer between min. and max dimming values
67: Ignore start level This parameter is used with association group 3
68: Dimming duration This parameter is used with association group 3
100: Enable / Disable Endpoints I2 Enabling I2 means that Endpoint (I2) will be present on UI.
101: Enable / Disable Endpoints I3 Enabling I3 means that Endpoint (I3) will be present on UI.
110: Temperature sensor offset settings Offset to actual measured value
120: Digital temperature sensor reporting Module reports measured temperature on defined temperature change
1: Controller Updates Lifeline group
2: I1 basic on/off Triggered at change of the input I1 state and reflecting its state
3: I1 start/stop level change Triggered at change of the input I1 state and reflecting its state
4: Multilevel Triggered at changes of state/value of the Flush Dimmer
5: I2 basic on/off Triggered at change of the input I2 state and reflecting its state
6: I2 notification report Triggered at change of the input I2 state and reflecting its state
7: I2 binary sensor Triggered at change of the input I2 state and reflecting its state
8: I3 basic on/off Triggered at change of the input I3 state and reflecting its state
9: I3 notification report Triggered at change of the input I3 state and reflecting its state
10: I3 binary sensor Triggered at change of the input I3 state and reflecting its state
11: Multilevel sensor Triggered at change of temperature sensor

1: Input 1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Mono-stable switch type (push button) (0)      
  1 - Bi-stable switch type (1)      

2: Input 2 switch type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options 0 - Mono-stable switch type (push button) (0)      
  1 - Bi-stable switch type (1)      

3: Input 2 contact type

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options 0 - NO (normally open) input type (0)      
  1 - NC (normally closed) input type (1)      

4: Input 3 contact type

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options 0 - NO (normally open) input type (0)      
  1 - NC (normally closed) input type (1)      

10: Activate / deactivate functions ALL ON / ALL OFF

Flush dimmer module responds to commands ALL ON / ALL OFF

Overview

Flush dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_2      
Data Type INTEGER   Default Value 255
Options ALL ON is not active, ALL OFF is not active (0)      
  ALL ON is not active, ALL OFF active (1)      
  ALL ON active, ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

11: Automatic turning off output after set time

Auto OFF enabled with defined time, step is 1 second.

Overview
  • 0 - Auto OFF disabled
  • 1 – 32536 = 1 second – 32536 seconds
Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 32536
Default Value 0

12: Automatic turning on output after set time

Auto ON enabled with defined time, step is 1 second.

Overview
  • 0 - Auto ON disabled
  • 1 – 32536 = 1 second – 32536 seconds
Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 32536
Default Value 0

20: Enable / Disable 3-way switch

Dimming is done by push button or switch connected to I1.

Overview

Dimming is done by push button or switch connected to I1 (by default).

Enabling 3way switch, dimming can be controlled by push button or switch connected to I1 and I2.

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 0
Options 0 - single push button (connected to I1) (0)      
  1 - 3-way switch (connected to I1 and I2) (1)      
  2 - Additional switch connected to I2 (2)      

21: Enable / Disable Double click function

A fast double click on the push button will set dimming power at maximum.

Overview

If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value.

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 0
Options 0 - double click disabled (0)      
  1 - double click enabled (1)      

30: Saving the state of the device after a power failure

If enabled, flush dimmer module saves its state before power failure.

Overview

If state saving is enabled, flush dimmer module saves its state before power failure (it returns to the last position saved before a power failure).

If state saving is disabled, flush dimmer module does not save the state after a power failure.

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options 0 - Save state enabled (0)      
  1 - Save state disabled (1)      

40: Power reporting in watts on power change

Set value is percentage, set value from 0 - 100 = 0% - 100%.

Overview

Set value means percentage, set value from 0 - 100 = 0% - 100%. Default value is 5.

  • 0 – Reporting Disabled
  • 1 – 100 = 1% - 100% Reporting enabled.

Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 100
Default Value 5

42: Power reporting in Watts by time interval

Set value means time interval (0 – 32767) in seconds.

Overview

Set value means time interval (0 – 32767) in seconds, when power report is sent.

  • 0 – reporting disabled
  • 1 – 32767 = 1 second – 32767 seconds. Reporting enabled.

Power report is send with time interval set by entered value.

Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 32767
Default Value 300

60: Minimum dimming value

Minimum dimming value is set by entered value.

Overview
  • 1-98 = 1% – 98%, step is 1%. Minimum dimming value is set by entered value.

NOTE: The minimum level may not be higher than the maximum level! 1% min. dimming value is defined by Z- Wave multilevel device class.

Property Value
Configuration ID config_60_1
Data Type INTEGER
Range 1 to 98
Default Value 1

61: Maximum dimming value

Maximum dimming value is set by entered value.

Overview
  • 2-99 = 2% – 99%, step is 1%. Maximum dimming value is set by entered value.

NOTE: The maximum level may not be lower than the minimum level! 99% max. dimming value is defined by Z- Wave multilevel device class.

Property Value
Configuration ID config_61_1
Data Type INTEGER
Range 2 to 99
Default Value 99

65: Dimming time (soft on/off)

Set value means time of moving the Dimmer between min. and max. dimming values

Overview

Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI (BasicSet).

  • default value 100 = 1s
  • 1 - 255 = 100 mseconds – 25500 mseconds, step is 10 mseconds
Property Value
Configuration ID config_65_2
Data Type INTEGER
Range 1 to 255
Default Value 100

66: Dimming time when key pressed

Time of moving the Dimmer between min. and max dimming values

Overview

Time of moving the Dimmer between min. and max dimming values by continuous hold of push button I1 or associated device.

  • default value 3 = 3s
  • 1- 255 = 1 second – 255 seconds.
Property Value
Configuration ID config_66_2
Data Type INTEGER
Range 1 to 255
Default Value 3

67: Ignore start level

This parameter is used with association group 3

Overview

This parameter is used with association group 3. A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. A receiving device MUST ignore the start level if the Ignore Start Level bit is 1.

Property Value      
Configuration ID config_67_1      
Data Type INTEGER   Default Value 0
Options 0 - respect start level (0)      
  1 - ignore start level (1)      

68: Dimming duration

This parameter is used with association group 3

Overview

This parameter is used with association group 3. The Duration field MUST specify the time that the transition should take from the current value to the new target value. A supporting device SHOULD respect the specified Duration value.

Property Value
Configuration ID config_68_1
Data Type INTEGER
Range 0 to 127
Default Value 0

100: Enable / Disable Endpoints I2

Enabling I2 means that Endpoint (I2) will be present on UI.

Overview

Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint.

NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module!

NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security.

Property Value      
Configuration ID config_100_1      
Data Type INTEGER   Default Value 0
Options 0 – Disabled (0)      
  1 – Home Security (1)      
  2 – Carbon Monoxide (2)      
  3 – Carbon Dioxide (3)      
  4 – Water Alarm (4)      
  5 – Heat Alarm (5)      
  6 - Smoke Alarm (6)      
  9 – Sensor binary (9)      

101: Enable / Disable Endpoints I3

Enabling I3 means that Endpoint (I3) will be present on UI.

Overview

Enabling I3 means that Endpoint (I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint.

NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module!

NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security.

Property Value      
Configuration ID config_101_1      
Data Type INTEGER   Default Value 0
Options 0 – Disabled (0)      
  1 – Home Security (1)      
  2 – Carbon Monoxide (2)      
  3 – Carbon Dioxide (3)      
  4 – Water Alarm (4)      
  5 – Heat Alarm (5)      
  6 - Smoke Alarm (6)      
  9 – Sensor binary (9)      

110: Temperature sensor offset settings

Offset to actual measured value

Overview

Set value is added or subtracted to actual measured value by sensor. Available configuration parameters:

  • default value 32536
  • 32536 – offset is 0.0C
  • From 1 to 100 – value from 0.1 °C to 10.0 °C is added to actual measured temperature.
  • From 1001 to 1100 -value from -0.1 °C to -10.0 °C is subtracted to actual measured temperature.
Property Value
Configuration ID config_110_2
Data Type INTEGER
Range 1 to 32536
Default Value 32536

120: Digital temperature sensor reporting

Module reports measured temperature on defined temperature change

Overview

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters:

  • default value 5 = 0.5°C
  • 0 – Reporting disabled
Property Value
Configuration ID config_120_1
Data Type INTEGER
Range 0 to 127
Default Value 5

1: Controller Updates

Lifeline group

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: I1 basic on/off

Triggered at change of the input I1 state and reflecting its state

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: I1 start/stop level change

Triggered at change of the input I1 state and reflecting its state

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Multilevel

Triggered at changes of state/value of the Flush Dimmer

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: I2 basic on/off

Triggered at change of the input I2 state and reflecting its state

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: I2 notification report

Triggered at change of the input I2 state and reflecting its state

Property Value
Configuration ID group_6
Data Type TEXT
Range to

7: I2 binary sensor

Triggered at change of the input I2 state and reflecting its state

Property Value
Configuration ID group_7
Data Type TEXT
Range to

8: I3 basic on/off

Triggered at change of the input I3 state and reflecting its state

Property Value
Configuration ID group_8
Data Type TEXT
Range to

9: I3 notification report

Triggered at change of the input I3 state and reflecting its state

Property Value
Configuration ID group_9
Data Type TEXT
Range to

10: I3 binary sensor

Triggered at change of the input I3 state and reflecting its state

Property Value
Configuration ID group_10
Data Type TEXT
Range to

11: Multilevel sensor

Triggered at change of temperature sensor

Property Value
Configuration ID group_11
Data Type TEXT
Range to