ZMNHIA Flush on/off thermostat

This describes the Z-Wave device ZMNHIA, manufactured by Goap with the thing type UID of qubino_zmnhia_00_000.

Flush on/off thermostat

Channels

The following table summarises the channels available for the ZMNHIA Flush on/off thermostat.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Thermostat mode thermostat_mode qubino_zmnhia_00_000_thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint_heating thermostat_setpoint Temperature Number
Binary Sensor 1 sensor_binary1 sensor_binary Door Switch
Binary Sensor 2 sensor_binary2 sensor_binary Door Switch

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHIA Flush on/off thermostat. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type Input 1 switch type
2: Input 2 switch type Input 2 switch type
3: Input 3 switch type Input 3 switch type
4: Input 2 contact type  
5: Input 3 contact type  
10: Activate / deactivate functions ALL ON/ALL OFF Module responds to commands ALL ON / ALL OFF
11: Set point set by I2 Set point set by I2
12: Set point set by I3 Set point set by I3
30: Saving the state of the relay after a power failure Saving the state of the relay after a power failure
40: Power reporting in Watts on power change for Q1 Power reporting in Watts on power change
42: Power reporting in Watts by time interval for Q1 Power reporting in Watts by time interval
43: Hysteresis On Hysteresis On
44: Hysteresis Off Hysteresis Off
45: Antifreeze Antifreeze function Temperature
60: Too low temperature limit Too low temperature limit
61: Too high temperature limit Too high temperature limit
63: Switch selection Connected device type can be (NO) or (NC)
1: Basic on/off Q1  
2: Basic on/off I2  
3: Basic on/off I3  
4: High Temperature  
5: Low Temperature  
6: Default Reporting Group  

1: Input 1 switch type

Input 1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

2: Input 2 switch type

Input 2 switch type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

3: Input 3 switch type

Input 3 switch type

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

4: Input 2 contact type

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

5: Input 3 contact type

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

10: Activate / deactivate functions ALL ON/ALL OFF

Module responds to commands ALL ON / ALL OFF

Overview

Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 255
Options ALL ON is not active ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

11: Set point set by I2

Set point set by I2

Overview

When I2 is pressed set point will be set according to the value of this parameter. Available config. parameters:

default value 65535

65535 – input I2 does not influence on the set point

From 0 to 990 – set point from 0.0 °C to 99.0 °C

From 1001 to 1150 – set point from -0.1 °C to -15.0 °C

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

12: Set point set by I3

Set point set by I3

Overview

When I3 is pressed set point will be set according to the value of this parameter. Available config. parameters

default value 65535

65535 – input I3 does not influence on the set point

From 0 to 990 – set point from 0.0 °C to 99.0 °C

From 1001 to 1150 – set point from -0.1 °C to -15.0 °C

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

30: Saving the state of the relay after a power failure

Saving the state of the relay after a power failure

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options Module saves its state (0)      
  Module does not save state (1)      

40: Power reporting in Watts on power change for Q1

Power reporting in Watts on power change

Overview

Set value means percentage, set value from 0 - 100=0% - 100%. Available configuration parameters

default value 3

0 – Reporting Disabled

1–100 = 1%-100% Reporting enabled. Power report is sent (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

NOTE: If power changed is less than 1W, the report is not sent (pushed), independent of percentage set.

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 255
Default Value 1

42: Power reporting in Watts by time interval for Q1

Power reporting in Watts by time interval

Overview

Set value means time interval (0 – 65535) in seconds, when power report is send. Available config. parameters

default value 300 (power report in Watts is send each 300s)

0 – Reporting Disabled

1 – 65535 = 1second – 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value.

Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 65535
Default Value 300

43: Hysteresis On

Hysteresis On

Overview

This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device on. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.7 °C.

Available configuration parameters

default value 132 (-0.5 °C)

Property Value
Configuration ID config_43_1
Data Type INTEGER
Range 0 to 255
Default Value 132

44: Hysteresis Off

Hysteresis Off

Overview

This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.7 °C.

Available configuration parameters

default value 5 (+0.5 °C)

Property Value
Configuration ID config_44_1
Data Type INTEGER
Range 0 to 255
Default Value 5

45: Antifreeze

Antifreeze function Temperature

Overview

Set value means at which temperature the device will be turned on even if the thermostat was manually set to off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 254 means from - 0.1 °C to -12.6 °C.

Available configuration parameters

default value 50 (5,0 °C)

255 – Antifreeze functionality disabled

Property Value
Configuration ID config_45_1
Data Type INTEGER
Range 0 to 255
Default Value 5

60: Too low temperature limit

Too low temperature limit

Overview

Available configuration parameters

Default value 50 (Too low temperature limit is 5.0°C)

1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value.

Property Value
Configuration ID config_60_2
Data Type INTEGER
Range 0 to 65535
Default Value 50

61: Too high temperature limit

Too high temperature limit

Overview

Available configuration parameters:

Default value 50 (Too low temperature limit is 5.0°C)

1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value.

Property Value
Configuration ID config_61_2
Data Type INTEGER
Range 0 to 65535
Default Value 700

63: Switch selection

Connected device type can be (NO) or (NC)

Overview

Set value means the type of the device that is connected to the relay output. The device type can be normally open (NO) or normally close (NC). Available configuration parameters

default value 0

0 - When system is turned off the output is 0 V.

1 - When system is turned off the output is 230 V.

Property Value
Configuration ID config_63_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

1: Basic on/off Q1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic on/off I2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Basic on/off I3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: High Temperature

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Low Temperature

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: Default Reporting Group

Property Value
Configuration ID group_6
Data Type TEXT
Range to