ZMNHID Flush on/off thermostat

This describes the Z-Wave device ZMNHID, manufactured by Goap with the thing type UID of qubino_zmnhid_00_000.

Flush on/off thermostat

Channels

The following table summarises the channels available for the ZMNHID Flush on/off thermostat.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Thermostat mode thermostat_mode qubino_zmnhid_00_000_thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint_heating thermostat_setpoint Temperature Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHID Flush on/off thermostat. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type Input 1 switch type
2: Input 2 switch type Input 2 switch type
3: Input 3 switch type Input 3 switch type
4: Input 2 contact type  
5: Input 3 contact type  
10: Activate / deactivate functions ALL ON/ALL OFF Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by…
11: Set point set by I2 Set point set by I2
12: Set point set by I3 65535 – input I3 does not influence on the set point
40: Power reporting in Watts on power change for Q1 Power report is sent (pushed) only when actual power in Watts in real time changed for mor…
42: Power reporting in Watts by time interval for Q1 default value is 300 (power report in Watts is sent each 300s)
43: Hysteresis On This parameter defines temperature min difference between real measured temperature and se…
44: Hysteresis Off This parameter defines temperature min difference between real measured temperature and se…
45: Antifreeze Set value means at which temperature the device will be turned on even if the thermostat w…
60: Too low temperature limit 1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered val…
61: Too high temperature limit 1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered val…
63: Switch selection Set value means the type of the device that is connected to the relay output. The device t…
1: Basic on/off Q1  
2: Basic on/off I2  
3: Basic on/off I3  
4: High Temperature  
5: Low Temperature  
6: Default Reporting Group  

1: Input 1 switch type

Input 1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

2: Input 2 switch type

Input 2 switch type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

3: Input 3 switch type

Input 3 switch type

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

4: Input 2 contact type

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

5: Input 3 contact type

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

10: Activate / deactivate functions ALL ON/ALL OFF

Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 255
Options ALL ON is not active ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

11: Set point set by I2

Set point set by I2

Overview

When I2 is pressed set point will be set according to the value of this parameter. Available config. parameters

Default Value 65535

65535 - input I2 does not influence on the set point.

From 0 to 990 - set point from 0.0 °C to 99.0 °C

From 1001 to 1150 - set point from -0.1 °C to -15.0 °C

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

12: Set point set by I3

65535 – input I3 does not influence on the set point
From 0 to 990 set point from 0.0 °C to 99.0 °C
From 1001 to 1150 – set point from -0.1 °C to -15.0 °C

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

40: Power reporting in Watts on power change for Q1

Power report is sent (pushed) only when actual power in Watts in real time changed for more than set percentage comparing to previous actual power in Watts, step is 1%.

  • 0 = Reporting Disabled
  • 1–100 = 1% - 100% Reporti
Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 255
Default Value 1

42: Power reporting in Watts by time interval for Q1

default value is 300 (power report in Watts is sent each 300s)

  • 0 = Reporting Disabled
  • 1–65535 = 1 second – 65535 seconds. Reporting enabled. Power report is sent with time interval set by entered value.
Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 65535
Default Value 300

43: Hysteresis On

This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device on. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.

Property Value
Configuration ID config_43_1
Data Type INTEGER
Range 0 to 255
Default Value 132

44: Hysteresis Off

This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device on. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.

Property Value
Configuration ID config_44_1
Data Type INTEGER
Range 0 to 255
Default Value 5

45: Antifreeze

Set value means at which temperature the device will be turned on even if the thermostat was manually set to off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 254 means from - 0.1 °C to -12.6 °C. 255 is di

Property Value
Configuration ID config_45_1
Data Type INTEGER
Range 0 to 255
Default Value 5

60: Too low temperature limit

1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value.

Property Value
Configuration ID config_60_2
Data Type INTEGER
Range 0 to 65535
Default Value 50

61: Too high temperature limit

1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value.

Property Value
Configuration ID config_61_2
Data Type INTEGER
Range 0 to 65535
Default Value 700

63: Switch selection

Set value means the type of the device that is connected to the relay output. The device type can be normally open (NO) or normally close (NC). Available configuration parameters (data type is 1 Byte DEC): • default value 0 • 0 - When system is turned

Property Value
Configuration ID config_63_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

1: Basic on/off Q1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic on/off I2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Basic on/off I3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: High Temperature

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Low Temperature

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: Default Reporting Group

Property Value
Configuration ID group_6
Data Type TEXT
Range to