ZMNHLA Flush PWM thermostat

This describes the Z-Wave device ZMNHLA, manufactured by Goap with the thing type UID of qubino_zmnhla_00_000.

Flush PWM thermostat

Channels

The following table summarises the channels available for the ZMNHLA Flush PWM thermostat.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Thermostat mode thermostat_mode qubino_zmnhla_00_000_thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint_heating thermostat_setpoint Temperature Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHLA Flush PWM thermostat. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type Input 1 switch type
2: Input 2 switch type Input 2 switch type
3: Input 3 switch type Input 3 switch type
4: Input 1 contact type Input 1 contact type
5: Input 2 contact type Input 2 contact type
6: Input 3 contact type Input 3 contact type
10: Activate / deactivate functions ALL ON/ALL OFF Respond to ALL ON/ALL OFF
11: I1 Functionality Selection Default Value = 1. 65535 – Input I1 does not influence on the heat/cool process. 1 - Input…
12: I2 Functionality Selection Default = 65535, 65535 - I2 does not influence on the heat/cool process, From From 0 to 99…
13: I3 Functionality Selection Default Value = 65535. 65535 – Input I3 does not influence on the heat/cool process. 1 - I…
40: Power reporting in Watts on power change Default Value = 0. 0 – Reporting Disabled 1 - 100 = 1% - 100% Reporting enabled. Power rep…
42: Power reporting in Watts by timer interval Default Value = 300. 0 – Reporting Disabled 1 - 32767 = 1 second - 32767 seconds Reporting…
45: Antifreeze Set value at which temperature the device will be turned on even if the termpearture was m…
50: PWM Maximum Value 2 - 100 = 2% - 100%, step is 1% Max PWM set by entered value. Default = 100. The Maximum l…
51: PWM Minimum Value 1 - 99 = 1% - 99%, step is 1% Minimum PWM set by entered value. Default = 0. The Minimum l…
52: PWM Cycle Duration 1 - 127 = 1-127 seconds, step is 1s PWM Cycle Duration set by entered value. Default = 10….
53: PID Value Inside Deadband When value is set to ZERO PID inside deadband is forced to zero. LAST VALUE means PID rema…
54: PID Deadband 0 - 127 = 0.0C - 12.7C step is 0.1 C This parameter defines the zone where PID is not acti…
55: Integral Sampling Time 0 - 127 = 0s -127s step is 1s Parameter defines the time between samples. On each sample t…
56: P Parameter 0 - 1000 P value step is 1. Default = 100
57: I Parameter 0 - 1000 - 0s I value step is 1. Default = 1
58: D Parameter 0 - 1000 - 0s D value step is 1. Default = 1
59: Thermostat Mode  
60: Too low temperature limit 1 - 1000 = 0.1 C - 100.0 C step is 0.1 C Too low temperature limit is set by entered value…
61: Too high temperature limit 1 - 1000 = 0.1 C - 100.0 C step is 0.1 C Too high temperature limit is set by entered valu…
63: Output Switch Selection  
70: Input 1 Status on delay 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influen…
71: Input 1 Status off delay 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influen…
72: Input 2 Status on delay 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influen…
73: Input 2 Status off delay 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influen…
74: Input 3 Status on delay 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influen…
75: Input 3 Status off delay 1 - 32000 seconds. If the value of the parameter is different to 0, means that the influen…
1: On/Off Triggered by Q State  
2: On/Off Triggered by I2  
3: On/Off Triggered by I3  
4: On/Off Triggerd by High Temp  
5: On/Off Trigger by Low Temp  
6: Controller Updates  

1: Input 1 switch type

Input 1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

2: Input 2 switch type

Input 2 switch type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

3: Input 3 switch type

Input 3 switch type

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

4: Input 1 contact type

Input 1 contact type

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

5: Input 2 contact type

Input 2 contact type

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

6: Input 3 contact type

Input 3 contact type

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

10: Activate / deactivate functions ALL ON/ALL OFF

Respond to ALL ON/ALL OFF

Overview

Flush PWM thermostat module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.           

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 255
Options ALL ON is not active ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

11: I1 Functionality Selection

Default Value = 1. 65535 – Input I1 does not influence on the heat/cool process. 1 - Input I1 changes the mode of the thermostat between OFF and AUTO. In this case function on flood sensor (if connected) is disabled. 2 - inpu

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 1 to 65535
Default Value 1

12: I2 Functionality Selection

Default = 65535, 65535 - I2 does not influence on the heat/cool process, From From 0 to 990 - Temperature set point from 0.0 C to 99.0 C. When I2 is pressed, the temperature set point is automatically set to value defined here. In

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 1 to 65535
Default Value 65535

13: I3 Functionality Selection

Default Value = 65535. 65535 – Input I3 does not influence on the heat/cool process. 1 - Input I3 changes the mode of the thermostat between OFF and AUTO. In this case function on window sensor is disabled. 2 - input I3 influ

Property Value
Configuration ID config_13_2
Data Type INTEGER
Range 1 to 65535
Default Value 65535

40: Power reporting in Watts on power change

Default Value = 0. 0 – Reporting Disabled 1 - 100 = 1% - 100% Reporting enabled. Power report is sent (pushed) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 100
Default Value 0

42: Power reporting in Watts by timer interval

Default Value = 300. 0 – Reporting Disabled 1 - 32767 = 1 second - 32767 seconds Reporting enabled. Power report is sent with time interval set by entered value.

Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 32767
Default Value 300

45: Antifreeze

Set value at which temperature the device will be turned on even if the termpearture was manually set to off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 C to 12.7 C and from 128 to 254 means from -0.1 C to -12.6 C

Property Value
Configuration ID config_45_1
Data Type INTEGER
Range 0 to 255
Default Value 50

50: PWM Maximum Value

2 - 100 = 2% - 100%, step is 1% Max PWM set by entered value. Default = 100. The Maximum level may not be lower than the minimum level.

Property Value
Configuration ID config_50_1
Data Type INTEGER
Range 2 to 100
Default Value 100

51: PWM Minimum Value

1 - 99 = 1% - 99%, step is 1% Minimum PWM set by entered value. Default = 0. The Minimum level may exceed the maximum level.

Property Value
Configuration ID config_51_1
Data Type INTEGER
Range 0 to 99
Default Value 0

52: PWM Cycle Duration

1 - 127 = 1-127 seconds, step is 1s PWM Cycle Duration set by entered value. Default = 10. NOTE:PWM Cycle duration defines the summary of all ON plus OFF time periods. For example if Output is set to 70% with PWM cycle duration of 20s,

Property Value
Configuration ID config_52_1
Data Type INTEGER
Range 1 to 127
Default Value 10

53: PID Value Inside Deadband

When value is set to ZERO PID inside deadband is forced to zero. LAST VALUE means PID remains on same level as was before entering into deadband.

Property Value      
Configuration ID config_53_1      
Data Type INTEGER   Default Value 0
Options PID value equals ZERO (0)      
  PID value set to LAST VALUE (1)      

54: PID Deadband

0 - 127 = 0.0C - 12.7C step is 0.1 C This parameter defines the zone where PID is not active. If the temperature difference between actual and setpoint is bigger than PID deadband, then the PID will start to regulate the system, otherw

Property Value
Configuration ID config_54_1
Data Type INTEGER
Range 0 to 127
Default Value 5

55: Integral Sampling Time

0 - 127 = 0s -127s step is 1s Parameter defines the time between samples. On each sample the controller captures difference between SP-act.

Property Value
Configuration ID config_55_1
Data Type INTEGER
Range 0 to 127
Default Value 5

56: P Parameter

0 - 1000 P value step is 1. Default = 100

Property Value
Configuration ID config_56_2
Data Type INTEGER
Range 0 to 1000
Default Value 100

57: I Parameter

0 - 1000 - 0s I value step is 1. Default = 1

Property Value
Configuration ID config_57_2
Data Type INTEGER
Range 0 to 1000
Default Value 1

58: D Parameter

0 - 1000 - 0s D value step is 1. Default = 1

Property Value
Configuration ID config_58_2
Data Type INTEGER
Range 0 to 1000
Default Value 1

59: Thermostat Mode

Property Value      
Configuration ID config_59_1      
Data Type INTEGER   Default Value 0
Options Heat Mode (0)      
  Cool Mode (1)      

60: Too low temperature limit

1 - 1000 = 0.1 C - 100.0 C step is 0.1 C Too low temperature limit is set by entered value. In case measured temperature is below set value, module sends BasicSet value. Default = 50

Property Value
Configuration ID config_60_2
Data Type INTEGER
Range 1 to 1000
Default Value 50

61: Too high temperature limit

1 - 1000 = 0.1 C - 100.0 C step is 0.1 C Too high temperature limit is set by entered value. In case measured temperature is higher than set value, module sends BasicSet value. Default = 700

Property Value
Configuration ID config_61_2
Data Type INTEGER
Range 1 to 1000
Default Value 700

63: Output Switch Selection

Property Value      
Configuration ID config_63_1      
Data Type INTEGER   Default Value 0
Options When system is turned off the output is 0V (NC) (0)      
  When system is turned off the output is 230V (NO) (1)      

70: Input 1 Status on delay

1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 11 must be set to 2!

Property Value
Configuration ID config_70_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

71: Input 1 Status off delay

1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 11 must be set to 2!

Property Value
Configuration ID config_71_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

72: Input 2 Status on delay

1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 12 must be set to 2000!

Property Value
Configuration ID config_72_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

73: Input 2 Status off delay

1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 12 must be set to 2000!

Property Value
Configuration ID config_73_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

74: Input 3 Status on delay

1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 13 must be set to 2!

Property Value
Configuration ID config_74_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

75: Input 3 Status off delay

1 - 32000 seconds. If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. Parameter 13 must be set to 2!

Property Value
Configuration ID config_75_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

1: On/Off Triggered by Q State

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: On/Off Triggered by I2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: On/Off Triggered by I3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: On/Off Triggerd by High Temp

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: On/Off Trigger by Low Temp

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: Controller Updates

Property Value
Configuration ID group_6
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.