ZMNHLD Flush PWM Thermostat

This describes the Z-Wave device ZMNHLD, manufactured by Goap with the thing type UID of qubino_zmnhld_00_000.

Flush PWM Thermostat

Overview

This Z-Wave module is used to regulate temperature.

Regulation is done using full wave PWM technology. The module can be controlled either through Z-wave network or through the wall switch.

The module is designed to be mounted inside a “flush mounting box” and is hidden behind a traditional wall switch.
Module measures power consumtion of connected device.

It is designed to act as repeater in order to improve range and stability of Z-wave network.

Inclusion Information

WARNING: Service button S must NOT be used when module is connected to 110-230V power supply.

  • Connect module to power supply (with temperature sensor connected - if purchased),
  • Enable add/remove mode on main controller
  • Auto-inclusion (works for about 2 minutesafter connected to power supply) or
  • 110V-230V power supply: Press push button I1 three times within 3 seconds (3 times change switch state within 3 seconds)
  • 24V SELV: Press service button S for more than 2 seconds.

NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.

NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply,connect the sensor and re-include the module.

Exclusion Information

WARNING: Service button S must NOT be used when module is connected to 110-230V power supply.

  • Connect module to power supply
  • Bring module within maximum 1 meter (3 feet) of the main controller
  • Enable add/remove mode on main controller
  • 110V-230V power supply: Press push button I1 five times within 3 seconds (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply
  • 24V SELV: Press ervice button S for more than 6 seconds.

By this function all parameters of the module are set to default values and own ID is deleted. If push button I1 is pressed three times within 3 seconds (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.

NOTE: If the module is included with parameters 100 or 101 with values different to default and module reset is done, wait at least 30s before next inclusion.

Channels

The following table summarises the channels available for the ZMNHLD Flush PWM Thermostat.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Thermostat mode thermostat_mode qubino_zmnhld_00_000_thermostat_mode Temperature Number
Thermostat setpoint thermostat_setpoint_heating thermostat_setpoint Temperature Number
Temperature Sensor sensor_temperature1 sensor_temperature Temperature Number
Thermostat mode thermostat_mode1 qubino_zmnhld_00_000_thermostat_mode Temperature Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Thermostat setpoint

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Temperature Sensor

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHLD Flush PWM Thermostat. Detailed information on each parameter can be found below.

Parameter Description
1: Input I1 switch type Input I1 switch type
2: Input I2 switch type Input I2 switch type
3: Input I3 switch type Input I3 switch type
4: Input 1 contact type Input 1 contact type
5: Input 2 contact type Input 2 contact type
6: Input 3 contact type Input 3 contact type
10: Activate / deactivate ALL ON/ALL OFF Activate / deactivate ALL ON/ALL OFF
11: I1 Functionality selection I1 Functionality selection
12: I2 Functionality selection I2 Functionality selection
13: I3 Functionality selection I3 Functionality selection
40: Power reporting in Watts on power change Power reporting in Watts on power change
42: Power reporting in Watts by time interval Power reporting in Watts by time interval
45: Antifreeze Antifreeze
50: PWM maximum value PWM maximum value
51: PWM minimum value PWM minimum value
52: PWM cycle duration PWM cycle duration
53: PID value inside deadband PID value inside deadband
54: PID deadband PID deadband
55: Integral sampling time Integral sampling time
56: P parameter P parameter
57: I parameter I parameter
58: D parameter D parameter
59: Thermostat mode Thermostat mode
60: Too low temperature limit Too low temperature limit
61: Too high temperature limit Too high temperature limit
63: Output switch selection Output switch selection
70: Input I1 status on delay Input I1 status on delay
71: Input I1 status off delay Input I1 status off delay
72: Input I2 status on delay Input I2 status on delay
73: Input I2 status off delay Input I2 status off delay
74: Input I3 status on delay Input I3 status on delay
75: Input I3 status off delay Input I3 status off delay
100: Enable/Disable Endpoint I1 or select type Enable/Disable Endpoint I1 or select type
101: Enable/Disable Endpoint I2 or select type Enable/Disable Endpoint I2 or select type
102: Enable/Disable Endpoint I3 or select type Enable/Disable Endpoint I3 or select type
110: Temperature sensor offset settings Temperature sensor offset settings
120: Digital temperature sensor reporting Digital temperature sensor reporting
121: Digital temperature sensor / setpoint selector Digital temperature sensor / setpoint selector
122: Node Id of external battery powered sensor Node Id of external battery powered sensor
1: Lifeline group reserved for communication with the main controller
2: basic on/off (output) Triggered at change of the output
3: Sensor_multilevel_get  
4: basic on/off (temp limit) triggered by Too high temperature limit
5: Thermostat setpoint get  
6: basic on/off (window) triggered by change of I1
7: basic on/off (condense sensor) triggered by change of I2
8: basic on/off (flood sensor) triggered by change of I3
9: sensor multilevel report Triggered at change of temperature

1: Input I1 switch type

Input I1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (0)      
  bi-stable switch type (1)      

2: Input I2 switch type

Input I2 switch type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (0)      
  bi-stable switch type (1)      

3: Input I3 switch type

Input I3 switch type

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (0)      
  bi-stable switch type (1)      

4: Input 1 contact type

Input 1 contact type

Overview

This parameter has influence only when parameter no. 11 is set to value “2”
After setting the parameter switch the sensor once, so tha the module could determine the input state

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options normally open (0)      
  normally closed (1)      

5: Input 2 contact type

Input 2 contact type

Overview

This parameter has influence only when parameter no. 12 is set to value “2000”
After setting the parameter switch the sensor once, so tha the module could determine the input state

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options normally open (0)      
  normally closed (1)      

6: Input 3 contact type

Input 3 contact type

Overview

This parameter has influence only when parameter no. 13 is set to value “2”
After setting the parameter switch the sensor once, so tha the module could determine the input state

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options normally open (0)      
  normally closed (1)      

10: Activate / deactivate ALL ON/ALL OFF

Activate / deactivate ALL ON/ALL OFF

Overview

Flush PWM thermostat module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controllers belonging to the system.

Property Value      
Configuration ID config_10_2      
Data Type INTEGER   Default Value 255
Options ALL ON is not active / ALL OFF is not active (0)      
  ALL ON is not active / ALL OFF is active (1)      
  ALL ON is active / ALL OFF is not active (2)      
  ALL ON is active / ALL OFF is active (255)      

11: I1 Functionality selection

I1 Functionality selection

Property Value      
Configuration ID config_11_2      
Data Type INTEGER   Default Value 1
Options Input I1 changes the mode between Off and Heat/Cool (1)      
  Input I1 influences the heating/cooling valves (2)      
  Input I1 doesnt influence on the Heat/Cool process (32767)      

12: I2 Functionality selection

I2 Functionality selection

Overview

0-990 - Temperature setpoint from 0,0 to 99,0 °C
1001-1150 - Temperature setpoint -0.1 to -15°C
2000 - Input I2 influences on the cooling value according to the status of condense sensor.

Property Value      
Configuration ID config_12_2      
Data Type INTEGER   Default Value 32767
Options Input I2 influences the cooling value with condense sensor (2000)      
  Input I2 doesnt influence on the Heat/Cool process (32767)      

13: I3 Functionality selection

I3 Functionality selection

Property Value      
Configuration ID config_13_2      
Data Type INTEGER   Default Value 32767
Options Input I3 changes the mode between Heat and Cool (1)      
  Input I3 influences the heating/cooling valves (2)      
  Input I3 doesnt influence on the Heat/Cool process (32767)      

40: Power reporting in Watts on power change

Power reporting in Watts on power change

Overview

0 - reporting disabled
1-100 = 1%-100% Reporting enabled
Power report is send only when actual power in Watts in real time changes for more then that set percentage

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 100
Default Value 0

42: Power reporting in Watts by time interval

Power reporting in Watts by time interval

Overview

0 - report disabled
1-32767 = 1 second - 32767 seconds interval. Reporting enabled with time interval

Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 32767
Default Value 0

45: Antifreeze

Antifreeze

Overview

Set value means at which temperature the thermostat will be turned on even if the thermostat was manually set off
0-127 = 0..12.7°C
1001-1127 = -0.1..-12.6°C
255 = Antifreeze is disabled

Property Value
Configuration ID config_45_2
Data Type INTEGER
Range 0 to 1127
Default Value 50

50: PWM maximum value

PWM maximum value

Overview

2..100 = 2..100% Maximum PWM is set by entered value

Property Value
Configuration ID config_50_1
Data Type INTEGER
Range 2 to 100
Default Value 100

51: PWM minimum value

PWM minimum value

Overview

0..99 = 0..99% Minimum PWM is set by entered value

Property Value
Configuration ID config_51_1
Data Type INTEGER
Range 0 to 99
Default Value 0

52: PWM cycle duration

PWM cycle duration

Overview

5..127 = 5-125 seconds. PWM cycle duration is set by entered value

Property Value
Configuration ID config_52_1
Data Type INTEGER
Range 5 to 127
Default Value 10

53: PID value inside deadband

PID value inside deadband

Overview

0 - PID value equals PWM minimum cycle
1 - PID value set to LAST VALUE

Property Value
Configuration ID config_53_1
Data Type INTEGER
Range 0 to 127
Default Value 0

54: PID deadband

PID deadband

Overview

0..127 = 0..12.7 °C
This parameter defines the zone where PID is not active.

Property Value
Configuration ID config_54_1
Data Type INTEGER
Range 0 to 127
Default Value 5

55: Integral sampling time

Integral sampling time

Overview

0..127 = 0..127 seconds.
Parameter defines the time between samples.

Property Value
Configuration ID config_55_1
Data Type INTEGER
Range 0 to 127
Default Value 5

56: P parameter

P parameter

Property Value
Configuration ID config_56_2
Data Type INTEGER
Range 0 to 1000
Default Value 100

57: I parameter

I parameter

Property Value
Configuration ID config_57_2
Data Type INTEGER
Range 0 to 1000
Default Value 1

58: D parameter

D parameter

Property Value
Configuration ID config_58_2
Data Type INTEGER
Range 0 to 1000
Default Value 1

59: Thermostat mode

Thermostat mode

Property Value      
Configuration ID config_59_1      
Data Type INTEGER   Default Value 0
Options Heat mode (0)      
  Cool mode (1)      

60: Too low temperature limit

Too low temperature limit

Overview

0..1000 = 0.1-100.0°C
1001..1150 = -0.1..-15.0°C

Property Value
Configuration ID config_60_2
Data Type INTEGER
Range 1 to 1150
Default Value 50

61: Too high temperature limit

Too high temperature limit

Overview

1..1000 = 0.1..100.0°C

Property Value
Configuration ID config_61_2
Data Type INTEGER
Range 1 to 1000
Default Value 700

63: Output switch selection

Output switch selection

Overview

Set value means the type of the device that is connected to the PWM output.

Property Value      
Configuration ID config_63_1      
Data Type INTEGER   Default Value 0
Options When the device is turned off the output is 0V (0)      
  When the system is turned off the output is 230V (1)      

70: Input I1 status on delay

Input I1 status on delay

Overview

If the value of the parameter is different to 0 means that the influence of this input to heating or cooling will react after inserted time.

Property Value
Configuration ID config_70_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

71: Input I1 status off delay

Input I1 status off delay

Overview

If the value of the parameter is different to 0 means that the influence of this input to heating or cooling will react after inserted time.

Property Value
Configuration ID config_71_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

72: Input I2 status on delay

Input I2 status on delay

Overview

If the value of the parameter is different to 0 means that the influence of this input to heating or cooling will react after inserted time.

Property Value
Configuration ID config_72_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

73: Input I2 status off delay

Input I2 status off delay

Overview

If the value of the parameter is different to 0 means that the influence of this input to heating or cooling will react after inserted time.

Property Value
Configuration ID config_73_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

74: Input I3 status on delay

Input I3 status on delay

Overview

If the value of the parameter is different to 0 means that the influence of this input to heating or cooling will react after inserted time.

Property Value
Configuration ID config_74_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

75: Input I3 status off delay

Input I3 status off delay

Overview

If the value of the parameter is different to 0 means that the influence of this input to heating or cooling will react after inserted time.

Property Value
Configuration ID config_75_2
Data Type INTEGER
Range 0 to 32000
Default Value 0

100: Enable/Disable Endpoint I1 or select type

Enable/Disable Endpoint I1 or select type

Property Value      
Configuration ID config_100_1      
Data Type INTEGER   Default Value 0
Options disabled (0)      
  Home security, motion detection (1)      
  CO - Carbon monoxid detected (2)      
  CO2 - Carbon dioxid detected (3)      
  Water alarm (4)      
  Heat alarm (5)      
  Smoke alarm (6)      
  Sensor binary (9)      

101: Enable/Disable Endpoint I2 or select type

Enable/Disable Endpoint I2 or select type

Property Value      
Configuration ID config_101_1      
Data Type INTEGER   Default Value 0
Options disabled (0)      
  Home security, motion detection (1)      
  CO - Carbon monoxid detected (2)      
  CO2 - Carbon dioxid detected (3)      
  Water alarm (4)      
  Heat alarm (5)      
  Smoke alarm (6)      
  Sensor binary (9)      

102: Enable/Disable Endpoint I3 or select type

Enable/Disable Endpoint I3 or select type

Property Value      
Configuration ID config_102_1      
Data Type INTEGER   Default Value 0
Options disabled (0)      
  Home security, motion detection (1)      
  CO - Carbon monoxid detected (2)      
  CO2 - Carbon dioxid detected (3)      
  Water alarm (4)      
  Heat alarm (5)      
  Smoke alarm (6)      
  Sensor binary (9)      

110: Temperature sensor offset settings

Temperature sensor offset settings

Overview

32536 = offset is 0.0°C
1..100 = offset is 0.1..10.0°C added to actual measuring value
1001..1100 = offset is -0.1..-10.0°C subtracted to actual measuring value

Property Value
Configuration ID config_110_2
Data Type INTEGER
Range 0 to 32536
Default Value 32536

120: Digital temperature sensor reporting

Digital temperature sensor reporting

Overview

If digital teperature sensor is connected, module reports measured temperature on temperture change defined by this parameter

Property Value
Configuration ID config_120_1
Data Type INTEGER
Range 0 to 127
Default Value 5

121: Digital temperature sensor / setpoint selector

Digital temperature sensor / setpoint selector

Property Value      
Configuration ID config_121_1      
Data Type INTEGER   Default Value 0
Options internal sensor is mounted (0)      
  temperature is grabbed by sensor with assoc 3 (1)      
  temperature is grabbed from ext battery sensor (2)      
  setpoint is grabbed by sensor with assoc 5 (4)      
  setpoint is grabbed from ext battery sensor (8)      
  temperature an setpoint are grabbed from ext batt sensor (10)      

122: Node Id of external battery powered sensor

Node Id of external battery powered sensor

Overview

0 - disabled

1..254 = NodeId of external battery powered room sensor

Property Value
Configuration ID config_122_1
Data Type INTEGER
Range 0 to 254
Default Value 0

1: Lifeline group

reserved for communication with the main controller

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: basic on/off (output)

Triggered at change of the output

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Sensor_multilevel_get

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: basic on/off (temp limit)

triggered by Too high temperature limit

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Thermostat setpoint get

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: basic on/off (window)

triggered by change of I1

Property Value
Configuration ID group_6
Data Type TEXT
Range to

7: basic on/off (condense sensor)

triggered by change of I2

Property Value
Configuration ID group_7
Data Type TEXT
Range to

8: basic on/off (flood sensor)

triggered by change of I3

Property Value
Configuration ID group_8
Data Type TEXT
Range to

9: sensor multilevel report

Triggered at change of temperature

Property Value
Configuration ID group_9
Data Type TEXT
Range to