ZMNHND Flush 1D relay

This describes the Z-Wave device ZMNHND, manufactured by Goap with the thing type UID of qubino_zmnhnd_00_000.

Flush 1D relay

Channels

The following table summarises the channels available for the ZMNHND Flush 1D relay.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Switch 1 switch_binary1 switch_binary Switch Switch
Sensor Binary sensor_binary2 sensor_binary Door Switch
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number
Burglar alarm_burglar2 alarm_burglar Door Switch

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Sensor (temperature) 2

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHND Flush 1D relay. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type Input 1 switch type
2: Input 2 contact type Input 2 contact type
10: Activate / deactivate functions ALL ON/ALL OFF Flush 1D relay module responds to commands ALL ON / ALL OFF that may be sent by the main c…
11: Automatic turning off relay after set time When relay is ON it goes automatically OFF after time defined by this parameter. Timer is …
12: Automatic turning on relay after set time When relay is OFF it goes automatically ON after time defined by this parameter. Timer is …
15: Automatic turning off / on seconds or milliseconds selection NOTE: Parameter is the same for turning OFF or ON.
30: Saving the state of the relay after a power failure Saving the state of the relay after a power failure
63: Output Switch selection Set value means the type of the device that is connected to the output. The device type ca…
100: Enable / Disable Endpoints I2 or select Notification Type and Event Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hi…
110: Temperature sensor offset settings Set value is added or subtracted to actual measured value by sensor. 32536 – offset is 0.0…
120: Digital temperature sensor reporting If digital temperature sensor is connected, module reports measured temperature on tempera…
1: Lifeline to Controller (reserved for communication with the main contr  
2: Basic on/off (triggered at change of the input Q state and reflectin  
3: Basic on/off (triggered at change of the input I2 state and reflecti  
4: Notification report (triggered at change of the input I2 state and r  
5: Binary Sensor (triggered at change of the input I2 state and reflect  
9: Multilevel Sensor report (triggered at change of temperature sensor)  

1: Input 1 switch type

Input 1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

2: Input 2 contact type

Input 2 contact type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options NO (normaly open) input type (0)      
  NC (normaly close) input type (1)      

10: Activate / deactivate functions ALL ON/ALL OFF

Flush 1D relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 255
Options ALL ON is not active ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

11: Automatic turning off relay after set time

When relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). 0 - Auto OFF disabled. 1

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

12: Automatic turning on relay after set time

When relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). 0 - Auto ON disabled. 1 –

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

15: Automatic turning off / on seconds or milliseconds selection

NOTE: Parameter is the same for turning OFF or ON.

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options Seconds selected (0)      
  Milliseconds selected (1)      

30: Saving the state of the relay after a power failure

Saving the state of the relay after a power failure

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options Flush 1D relay module saves its state before power failure (it returns (0)      
  Flush 1D relay module does not save the state after a power failure, i (1)      

63: Output Switch selection

Set value means the type of the device that is connected to the output. The device type can be normally open (NO) or normally close (NC).

Property Value      
Configuration ID config_63_1      
Data Type INTEGER   Default Value 0
Options When system is turned off the output is 0V (NC). (0)      
  When system is turned off the output is 230V or 24V (NO). (1)      

100: Enable / Disable Endpoints I2 or select Notification Type and Event

Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Endpoint device type selec

Property Value      
Configuration ID config_100_1      
Data Type INTEGER   Default Value 1
Options Endpoint, I2 disabled (0)      
  Home Security; Motion Detection, unknown loc. (1)      
  Carbon Monoxide; Carbon Monoxide detected, unknown location. (2)      
  Carbon Dioxide; Carbon Dioxide detected, unknown location. (3)      
  Water Alarm; Water Leak detected, unknown lo.. (4)      
  Heat Alarm; Overheat detected, unknown loc. (5)      
  Smoke Alarm; Smoke detected, unknown loc. (6)      
  Sensor binary. (9)      

110: Temperature sensor offset settings

Set value is added or subtracted to actual measured value by sensor. 32536 – offset is 0.0C From 1 to 100–value from 0.1°C to 10.0°C is added to actual measured temperature. From 1001 to 1100 – value from -0.1 °C to -10.0 °C is subtracted to actual mea

Property Value
Configuration ID config_110_2
Data Type INTEGER
Range 0 to 65535
Default Value 32536

120: Digital temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. 0 – Reporting disabled 1- 127 = 0,1°C – 12,7°C, step is 0,1°C

Property Value
Configuration ID config_120_1
Data Type INTEGER
Range 0 to 255
Default Value 5

1: Lifeline to Controller (reserved for communication with the main contr

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic on/off (triggered at change of the input Q state and reflectin

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Basic on/off (triggered at change of the input I2 state and reflecti

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Notification report (triggered at change of the input I2 state and r

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Binary Sensor (triggered at change of the input I2 state and reflect

Property Value
Configuration ID group_5
Data Type TEXT
Range to

9: Multilevel Sensor report (triggered at change of temperature sensor)

Property Value
Configuration ID group_9
Data Type TEXT
Range to