ZMNHOD Flush Shutter DC

This describes the Z-Wave device ZMNHOD, manufactured by Goap with the thing type UID of qubino_zmnhod_00_000.

Flush Shutter DC

Channels

The following table summarises the channels available for the ZMNHOD Flush Shutter DC.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Blinds control blinds_control blinds_control Blinds Rollershutter
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Switch 1 switch_binary1 switch_binary Switch Switch
Blinds control 1 blinds_control1 blinds_control Blinds Rollershutter
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number

Blinds control

Invert control

Invert the blinds control

Property Value      
Configuration ID config_invert_control      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Invert percentage value

Invert the blinds percentage value

Property Value      
Configuration ID config_invert_percent      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Step duration

Sets the dim rate speed
Values from 1 to 127 are defined in seconds, while values from 128 to 254 are defined in minutes.

Property Value      
Configuration ID config_duration      
Data Type INTEGER      
Range 1 to 254   Default Value 255
Options Device Default (255)      
  Change Instantly (0)      

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Blinds control 1

Invert control

Invert the blinds control

Property Value      
Configuration ID config_invert_control      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Invert percentage value

Invert the blinds percentage value

Property Value      
Configuration ID config_invert_percent      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Step duration

Sets the dim rate speed
Values from 1 to 127 are defined in seconds, while values from 128 to 254 are defined in minutes.

Property Value      
Configuration ID config_duration      
Data Type INTEGER      
Range 1 to 254   Default Value 255
Options Device Default (255)      
  Change Instantly (0)      

Sensor (temperature) 2

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHOD Flush Shutter DC. Detailed information on each parameter can be found below.

Parameter Description
10: Activate/deactivate functions ALL ON / ALL OFF Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by…
40: Power reporting in Watts on power change for Q1 or Q2 Set value 0 – 100 as percentage.
42: Power reporting in Watts by time interval for Q1 or Q2 Set value determines interval in seconds, when power report is send.
71: Operating modes This parameter defines selection between two available operating modes.
72: Slats tilting full turn time This parameter defines the time necessary for slats to make full turn (180 degrees)
73: Slats position This parameter defines slats position after up/down movement through Z-wave or push-button…
74: Motor moving up/down time This parameter defines shutter motor moving time of complete opening or complete closing.
76: Motor operation detection Power threshold to be interpreted when motor reaches the limit switch.
78: Forced Shutter DC calibration Setting value 0 or 1 a Shutter DC module enters the calibration mode.
85: Power consumption max delay time This parameter defines the max time before motor power consumption is read after one of th…
86: Power consumption at limit switch delay time This parameter defines the max time at limit switch, when power consumption is below power…
90: Time delay for next motor movement This parameter defines the minimum time delay between next motor movemen.
110: Temperature sensor offset settings Set value is added or subtracted to actual measured value by sensor. default value 32536 3…
120: Digital temperature sensor reporting If digital temperature sensor is connected, module reports measured temperature on tempera…
1: Default reporting group  
2: Basic on/off Triggered at change of the input I1 state and reflecting its state
3: Basic on/off Triggered at change of the input I2 state and reflecting its state
4: Basic on/off Triggered at sensing moving direction of roller
5: Basic on/off Triggered at reaching roller position
6: Basic on/off Triggered at reaching roller position
7: Multilevel set triggered at changes of value of the Flush Shutter DC position
8: Multilevel set Triggered at changes of value of slats tilting position
9: Multilevel sensor report Triggered at change of temperature sensor

10: Activate/deactivate functions ALL ON / ALL OFF

Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_2      
Data Type INTEGER   Default Value 255
Options ALL ON is not active, ALL OFF is not active (0)      
  ALL ON is not active ALL OFF active (1)      
  ALL ON is not active ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

40: Power reporting in Watts on power change for Q1 or Q2

Set value 0 – 100 as percentage.
Available configuration parameters.

  • 0 = Reporting Disabled
  • 1–100 = 1% - 100% Reporting enabled

Power report is sent only when actual power (in Watts) in real

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 100
Default Value 1

42: Power reporting in Watts by time interval for Q1 or Q2

Set value determines interval in seconds, when power report is send.
Available configuration parameters.

  • default value 300 = 300s
  • 0 – Reporting Disabled
  • 1 – 32767 = 1 second – 32767 seconds
Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 32767
Default Value 300

71: Operating modes

This parameter defines selection between two available operating modes.
NOTE: When setting parameter, module needs to be excluded and included again! Please check detailed description in this manual.

Property Value      
Configuration ID config_71_1      
Data Type INTEGER   Default Value 0
Options Shutter mode. (0)      
  Venetian mode (up/down and slate rotation) (1)      

72: Slats tilting full turn time

This parameter defines the time necessary for slats to make full turn (180 degrees)
NOTE: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining.

  • default value 15
Property Value
Configuration ID config_72_2
Data Type INTEGER
Range 0 to 32767
Default Value 150

73: Slats position

This parameter defines slats position after up/down movement through Z-wave or push-buttons.

Property Value      
Configuration ID config_73_1      
Data Type INTEGER   Default Value 1
Options Slats return to previously set position only in case of Z-wave control (0)      
  Slats return to previously set position in case of Z-wave control, pus (1)      

74: Motor moving up/down time

This parameter defines shutter motor moving time of complete opening or complete closing.
NOTE: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining.

  • defau
Property Value
Configuration ID config_74_2
Data Type INTEGER
Range 0 to 32767
Default Value 0

76: Motor operation detection

Power threshold to be interpreted when motor reaches the limit switch.

  • default value 6 = 0,6W
  • 5 - 100 (0,5W - 10W), step is 0,1W.
  • The value 0 means reaching a limit switch will not be detected
Property Value
Configuration ID config_76_1
Data Type INTEGER
Range 0 to 100
Default Value 6

78: Forced Shutter DC calibration

Setting value 0 or 1 a Shutter DC module enters the calibration mode.
When calibration process is finished, completing full cycle - up, down and up, set parameter 78 back to default of 0.

Property Value      
Configuration ID config_78_1      
Data Type INTEGER   Default Value 0
Options Default (0)      
  Start calibration process. (1)      

85: Power consumption max delay time

This parameter defines the max time before motor power consumption is read after one of the relays is switched ON.
If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, mo

Property Value
Configuration ID config_85_1
Data Type INTEGER
Range 3 to 50
Default Value 8

86: Power consumption at limit switch delay time

This parameter defines the max time at limit switch, when power consumption is below power threshold.
If the power consumption during this time is below power threshold (par. 76), the active output will switch off, means that limit sw

Property Value
Configuration ID config_86_1
Data Type INTEGER
Range 3 to 50
Default Value 8

90: Time delay for next motor movement

This parameter defines the minimum time delay between next motor movemen.
(minimum time between switching motor off and on again)

  • default value 5 = 500ms
  • 1 – 30 = 0,1seconds – 3seconds (100ms resolution)
Property Value
Configuration ID config_90_1
Data Type INTEGER
Range 1 to 30
Default Value 5

110: Temperature sensor offset settings

Set value is added or subtracted to actual measured value by sensor. default value 32536 32536 – offset is 0.0C From 1 to 100 – value from 0.1 °C to 10.0 °C is added to actual measured temperature.

Property Value
Configuration ID config_110_2
Data Type INTEGER
Range 1 to 32536
Default Value 32536

120: Digital temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.

  • Default value 5 = 0,5°C
  • 32536 – offset is 0.0C
  • 0 – Reporting disabled
Property Value
Configuration ID config_120_1
Data Type INTEGER
Range 0 to 127
Default Value 5

1: Default reporting group

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic on/off

Triggered at change of the input I1 state and reflecting its state

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Basic on/off

Triggered at change of the input I2 state and reflecting its state

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Basic on/off

Triggered at sensing moving direction of roller

Overview

up=FF, down=0

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Basic on/off

Triggered at reaching roller position

Overview

bottom=FF, top=0

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: Basic on/off

Triggered at reaching roller position

Overview

bottom=FF, not bottom=0

Property Value
Configuration ID group_6
Data Type TEXT
Range to

7: Multilevel set

triggered at changes of value of the Flush Shutter DC position

Property Value
Configuration ID group_7
Data Type TEXT
Range to

8: Multilevel set

Triggered at changes of value of slats tilting position

Property Value
Configuration ID group_8
Data Type TEXT
Range to

9: Multilevel sensor report

Triggered at change of temperature sensor

Property Value
Configuration ID group_9
Data Type TEXT
Range to