ZMNHSD DIN Rail Dimmer

This describes the Z-Wave device ZMNHSD, manufactured by Goap with the thing type UID of qubino_zmnhsd_00_000.

DIN Rail Dimmer

Channels

The following table summarises the channels available for the ZMNHSD DIN Rail Dimmer.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHSD DIN Rail Dimmer. Detailed information on each parameter can be found below.

Parameter Description
1: Input switch type  
5: Working mode With this parameter it is possible to change the module presentation on the user interface…
10: Activate / deactivate functions ALL ON / ALL OFF DIN dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main contr…
11: Automatic turning off output after set time  
12: Automatic turning on output after set time  
21: Enable / Disable Double click function If Double click function is enabled, a fast double click on the push button will set dimmi…
30: Saving the state of the device after a power failure If state saving is enabled, DIN dimmer module saves its state before power failure (it ret…
40: Power reporting in watts on power change Set value means percentage, set value from 0 - 100 = 0% - 100%. Default value is 5. 0 – Re…
42: Power reporting in Watts by time interval Set value means time interval (0 – 32767) in seconds, when power report is sent.
60: Minimum dimming value  
61: Maximum dimming value  
65: Dimming time (soft on/off) Set value means time of moving the Dimmer between min. and max. dimming values by short pr…
66: Dimming time when key pressed Time to moving the Dimmer between min. and max values (in seconds).
67: Ignore start level This parameter is used with association group 3. A receiving device SHOULD respect the sta…
68: Dimming duration This parameter is used with association group 3.
110: Temperature sensor offset settings Set value is added or subtracted to actual measured value by sensor. Available configurati…
120: Digital temperature sensor reporting If digital temperature sensor is connected, module reports measured temperature on tempera…
1: Controller Updates  
2: I1 basic on/off  
3: I1 start/stop level change  
4: Multilevel set  
5: Multilevel sensor report  

1: Input switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options 0 - Mono-stable switch type (push button) (0)      
  1 - Bi-stable switch type (1)      

5: Working mode

With this parameter it is possible to change the module presentation on the user interface.

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options Dimmer (0)      
  Switch (1)      

10: Activate / deactivate functions ALL ON / ALL OFF

DIN dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.

Property Value      
Configuration ID config_10_2      
Data Type INTEGER   Default Value 255
Options ALL ON is not active, ALL OFF is not active (0)      
  ALL ON is not active, ALL OFF active (1)      
  ALL ON active, ALL OFF is not active (2)      
  ALL ON active, ALL OFF active (255)      

11: Automatic turning off output after set time

Overview
  • 0 - Auto OFF disabled
  • 1 – 32536 = 1 second – 32536 seconds Auto OFF enabled with defined time, step is 1 second.
Property Value      
Configuration ID config_11_2      
Data Type INTEGER      
Range 0 to 32536   Default Value 0
Options Auto off DISABLED (0)      

12: Automatic turning on output after set time

Overview
  • 0 - Auto ON disabled
  • 1 – 32536 = 1 second – 32536 seconds Auto ON enabled with defined time, step is 1 second.
Property Value      
Configuration ID config_12_2      
Data Type INTEGER      
Range 0 to 32536   Default Value 0
Options Auto on DISABLED (0)      

21: Enable / Disable Double click function

If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value.

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 0
Options 0 - double click disabled (0)      
  1 - double click enabled (1)      

30: Saving the state of the device after a power failure

If state saving is enabled, DIN dimmer module saves its state before power failure (it returns to the last position saved before a power failure). If state saving is disabled, DIN dimmer module does not save the state after a powe

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options 0 - Save state enabled (0)      
  1 - Save state disabled (1)      

40: Power reporting in watts on power change

Set value means percentage, set value from 0 - 100 = 0% - 100%. Default value is 5. 0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled. Power report is sent (push) only when actual power in Watts in real time changes for more than set p

Property Value
Configuration ID config_40_1
Data Type INTEGER
Range 0 to 100
Default Value 5

42: Power reporting in Watts by time interval

Set value means time interval (0 – 32767) in seconds, when power report is sent.

Overview
  • 0 – reporting disabled
  • 1 – 32767 = 1 second – 32767 seconds. Reporting enabled. Power report is sent with time interval set by entered
Property Value
Configuration ID config_42_2
Data Type INTEGER
Range 0 to 32767
Default Value 300

60: Minimum dimming value

Overview
  • 1-98 = 1% – 98%, step is 1%. Minimum dimming value is set by entered value.

NOTE: The minimum level may not be higher than the maximum level! 1% min. dimming value is defined by Z- Wave multilevel device class.

Property Value
Configuration ID config_60_1
Data Type INTEGER
Range 1 to 98
Default Value 1

61: Maximum dimming value

Overview
  • 2-99 = 2% – 99%, step is 1%. Maximum dimming value is set by entered value.

NOTE: The maximum level may not be lower than the minimum level! 99% max. dimming value is defined by Z- Wave multilevel device class.

Property Value
Configuration ID config_61_1
Data Type INTEGER
Range 2 to 99
Default Value 99

65: Dimming time (soft on/off)

Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI (BasicSet).

  • default value 100 = 1s
  • 1 - 255 = 100 mseconds – 25500 mseconds (25.5
Property Value
Configuration ID config_65_2
Data Type INTEGER
Range 1 to 255
Default Value 100

66: Dimming time when key pressed

Time to moving the Dimmer between min. and max values (in seconds).

Overview
  • default value 3 = 3s
  • 1- 255 = 1 second – 255 seconds.
Property Value
Configuration ID config_66_2
Data Type INTEGER
Range 1 to 255
Default Value 3

67: Ignore start level

This parameter is used with association group 3. A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. A receiving device MUST ignore the start level if the Ignore Start Level bit is 1.

Property Value      
Configuration ID config_67_1      
Data Type INTEGER   Default Value 0
Options 0 - respect start level (0)      
  1 - ignore start level (1)      

68: Dimming duration

This parameter is used with association group 3.

Overview

The Duration field MUST specify the time that the transition should take from the current value to the new target value. A supporting device SHOULD respect the specified Duration value.

Property Value
Configuration ID config_68_1
Data Type INTEGER
Range 0 to 127
Default Value 0

110: Temperature sensor offset settings

Set value is added or subtracted to actual measured value by sensor. Available configuration parameters:

  • default value 32536
  • 32536 – offset is 0.0C
  • From 1 to 100 – value from 0.1 °C to 10.0 °C is added to
Property Value
Configuration ID config_110_2
Data Type INTEGER
Range 1 to 32536
Default Value 32536

120: Digital temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters:

  • default value 5 = 0.5°C
  • 0 – Reporting disabled
Property Value
Configuration ID config_120_1
Data Type INTEGER
Range 0 to 127
Default Value 5

1: Controller Updates

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: I1 basic on/off

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: I1 start/stop level change

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Multilevel set

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Multilevel sensor report

Property Value
Configuration ID group_5
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.