ZMNHUD Flush pilot (DIN version)

This describes the Z-Wave device ZMNHUD, manufactured by Goap with the thing type UID of qubino_zmnhud_00_000.

Flush pilot (DIN version)

Channels

The following table summarises the channels available for the ZMNHUD Flush pilot (DIN version).

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Binary Sensor sensor_binary sensor_binary Door Switch

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHUD Flush pilot (DIN version). Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 switch type  
2: Input 2 switch type  
3: Input 3 switch type  
4: Input 1 contact type  
5: Input 2 contact type  
6: Input 3 contact type  
11: Input 1 operation mode selection  
12: Input 2 operation mode selection  
13: Input 3 operation mode selection  
30: Saving the state of the device after a power failure  
1: Lifeline group Reserved for communication with the main controller
2: Multilevel Triggered at changes of state/value of the Flush pilot wire
3: Basic on/off Triggered at change of the input I1 state and reflecting its state
4: Basic on/off Triggered at change of the input I2 state and reflecting its state
5: Basic on/off Triggered at change of the input I3 state and reflecting its state

1: Input 1 switch type

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

2: Input 2 switch type

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

3: Input 3 switch type

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options mono-stable switch type (push button) (0)      
  bi-stable switch type (1)      

4: Input 1 contact type

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

5: Input 2 contact type

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

6: Input 3 contact type

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options NO (normally open) input type (0)      
  NC (normally close) input type (1)      

11: Input 1 operation mode selection

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 1
Options Button does not influence on selected mode (0)      
  Comfort (1)      
  Comfort-1°C (2)      
  Comfort-2°C (3)      
  Eco Mode (4)      
  Frost Protection (5)      
  Stop (6)      

12: Input 2 operation mode selection

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 4
Options Button does not influence on selected mode (0)      
  Comfort (1)      
  Comfort-1°C (2)      
  Comfort-2°C (3)      
  Eco Mode (4)      
  Frost Protection (5)      
  Stop (6)      

13: Input 3 operation mode selection

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 5
Options Button does not influence on selected mode (0)      
  Comfort (1)      
  Comfort-1°C (2)      
  Comfort-2°C (3)      
  Eco Mode (4)      
  Frost Protection (5)      
  Stop (6)      

30: Saving the state of the device after a power failure

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options The module saves its state before power failure (0)      
  The module does not save the state (1)      

1: Lifeline group

Reserved for communication with the main controller

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Multilevel

Triggered at changes of state/value of the Flush pilot wire

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Basic on/off

Triggered at change of the input I1 state and reflecting its state

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Basic on/off

Triggered at change of the input I2 state and reflecting its state

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Basic on/off

Triggered at change of the input I3 state and reflecting its state

Property Value
Configuration ID group_5
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.