ZMNHVD Flush Dimmer 0-10V

This describes the Z-Wave device ZMNHVD, manufactured by Goap with the thing type UID of qubino_zmnhvd_00_000.

Flush Dimmer 0-10V

Channels

The following table summarises the channels available for the ZMNHVD Flush Dimmer 0-10V.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Sensor (general) sensor_general sensor_general   Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHVD Flush Dimmer 0-10V. Detailed information on each parameter can be found below.

Parameter Description
1: Input 1 Switch Type By this parameter the user can set input based on device type (switch, potentiometer, 0-10…
11: Automatic turning off output after set time  
12: Automatic turning on output after set time  
21: Enable/Disable Double click function  
30: Saving the state of the device after a power failure  
52: Auto or manual selection  
53: PID value inside deadband  
54: PID deadband  
55: Integral sampling time  
56: P parameter  
57: I parameter  
58: D parameter Available config. parameters (data type is2 Byte DEC):
60: Minimum dimming value  
61: Maximum dimming value  
65: Dimming time (soft on/off)  
66: Dimming time when key pressed  
67: Ignore start level  
68: Dimming duration  
110: Temperature sensor offset settings  
120: Digital temperature sensor reporting  
140: Input I1 Sensor reporting  
141: Input I1 0-10V reporting threshold  
143: Minimum sensor range value  
144: Maximum sensor range value  
1: Lifeline Reserved for communication with the main controller
2: basic on/off triggered at change of the input I1 state and reflecting its state
3: start level change/stop level change triggered at change of the input I1 state and reflecting its state) up to 16 nodes. Workin…
4: multilevel set triggered at changes of state/value of the Flush Dimmer 0-10V
5: multilevel sensor report triggered at change of analogue sensor
6: multilevel sensor report triggered at change of temperature sensor

1: Input 1 Switch Type

By this parameter the user can set input based on device type (switch, potentiometer, 0-10V sensor,…)

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options mono-stable switch type (push button) (0)      
  Bi-stable switch type (1)      
  Potentiometer (2)      
  Temperature sensor (3)      
  Illumination sensor (4)      
  General purpose sensor (5)      

11: Automatic turning off output after set time

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 32536
Default Value 0

12: Automatic turning on output after set time

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 32535
Default Value 0

21: Enable/Disable Double click function

Property Value
Configuration ID config_21_1
Data Type INTEGER
Range 0 to 1
Default Value 0

30: Saving the state of the device after a power failure

Property Value
Configuration ID config_30_1
Data Type INTEGER
Range 0 to 1
Default Value 0

52: Auto or manual selection

Property Value
Configuration ID config_52_1
Data Type INTEGER
Range 0 to 1
Default Value 0

53: PID value inside deadband

Property Value
Configuration ID config_53_1
Data Type INTEGER
Range 0 to 1
Default Value 0

54: PID deadband

Property Value
Configuration ID config_54_1
Data Type INTEGER
Range 0 to 100
Default Value 1

55: Integral sampling time

Property Value
Configuration ID config_55_1
Data Type INTEGER
Range 0 to 127
Default Value 5

56: P parameter

Property Value
Configuration ID config_56_2
Data Type INTEGER
Range 0 to 1000
Default Value 100

57: I parameter

Property Value
Configuration ID config_57_2
Data Type INTEGER
Range 0 to 1000
Default Value 1

58: D parameter

Available config. parameters (data type is2 Byte DEC):

Property Value
Configuration ID config_58_2
Data Type INTEGER
Range 0 to 1000
Default Value 1

60: Minimum dimming value

Property Value
Configuration ID config_60_1
Data Type INTEGER
Range 1 to 98
Default Value 1

61: Maximum dimming value

Property Value
Configuration ID config_61_1
Data Type INTEGER
Range 2 to 99
Default Value 99

65: Dimming time (soft on/off)

Property Value
Configuration ID config_65_2
Data Type INTEGER
Range 1 to 255
Default Value 100

66: Dimming time when key pressed

Property Value
Configuration ID config_66_1
Data Type INTEGER
Range 1 to 255
Default Value 3

67: Ignore start level

Property Value
Configuration ID config_67_1
Data Type INTEGER
Range 0 to 1
Default Value 0

68: Dimming duration

Property Value
Configuration ID config_68_1
Data Type INTEGER
Range 0 to 127
Default Value 0

110: Temperature sensor offset settings

Property Value
Configuration ID config_110_2
Data Type INTEGER
Range 1 to 32536
Default Value 32536

120: Digital temperature sensor reporting

Property Value
Configuration ID config_120_1
Data Type INTEGER
Range 0 to 127
Default Value 0

140: Input I1 Sensor reporting

Property Value
Configuration ID config_140_2
Data Type INTEGER
Range 0 to 140
Default Value 5

141: Input I1 0-10V reporting threshold

Property Value
Configuration ID config_141_1
Data Type INTEGER
Range 0 to 100
Default Value 5

143: Minimum sensor range value

Property Value
Configuration ID config_143_2
Data Type INTEGER
Range 0 to 20000
Default Value 0

144: Maximum sensor range value

Property Value
Configuration ID config_144_2
Data Type INTEGER
Range 0 to 20000
Default Value 1000

1: Lifeline

Reserved for communication with the main controller

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: basic on/off

triggered at change of the input I1 state and reflecting its state

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: start level change/stop level change

triggered at change of the input I1 state and reflecting its state) up to 16 nodes. Working only when the Parameter no. 1 is set to mono stable switch type.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: multilevel set

triggered at changes of state/value of the Flush Dimmer 0-10V

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: multilevel sensor report

triggered at change of analogue sensor

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: multilevel sensor report

triggered at change of temperature sensor

Property Value
Configuration ID group_6
Data Type TEXT
Range to