ZMNHZD Multifunctional Weather Station

This describes the Z-Wave device ZMNHZD, manufactured by Goap with the thing type UID of qubino_zmnhzd_00_000.

Multifunctional Weather Station

Channels

The following table summarises the channels available for the ZMNHZD Multifunctional Weather Station.

Channel Channel Id Channel Type UID Category Item Type
Sensor (velocity) sensor_velocity sensor_velocity   Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (direction) sensor_direction sensor_direction   Number
Sensor (rain rate) sensor_rainrate sensor_rainrate Humidity Number
  battery-level system.battery-level    
Thermo/ Hygro Sensor Ch1 – Temperature sensor_temperature1 sensor_temperature Temperature Number
  battery-level1 system.battery-level    
Wind Gauge – Direction sensor_direction2 sensor_direction   Number
  battery-level2 system.battery-level    
Wind Gauge – Velocity sensor_velocity3 sensor_velocity   Number
  battery-level3 system.battery-level    
Wind Gauge – Wind gust sensor_velocity4 sensor_velocity   Number
  battery-level4 system.battery-level    
Wind Gauge – Temperature sensor_temperature5 sensor_temperature Temperature Number
  battery-level5 system.battery-level    
Wind Gauge – Wind Chill sensor_temperature6 sensor_temperature Temperature Number
  battery-level6 system.battery-level    
Rain Sensor sensor_rainrate7 sensor_rainrate Humidity Number
  battery-level7 system.battery-level    
Thermo/ Hygro Sensor Ch1 – Humidity sensor_relhumidity8 sensor_relhumidity Humidity Number
  battery-level8 system.battery-level    
Thermo/ Hygro Sensor Ch2 – Temperature sensor_temperature9 sensor_temperature Temperature Number
  battery-level9 system.battery-level    
Thermo/ Hygro Sensor Ch2 – Humidity sensor_relhumidity10 sensor_relhumidity Humidity Number
  battery-level10 system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Thermo/ Hygro Sensor Ch1 – Temperature

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Wind Gauge – Temperature

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Wind Gauge – Wind Chill

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Thermo/ Hygro Sensor Ch2 – Temperature

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZMNHZD Multifunctional Weather Station. Detailed information on each parameter can be found below.

Parameter Description
1: Wind Gauge Wind Gauge, Wind Gust Top Value
2: Rain Gauge Rain Rate top value
3: Wind Gauge Wind Gust
4: Rain Gauge Rain Rate
5: End Point 1 Unsolicited report
6: End Point 2 Unsolicited report
7: End Point 3 Unsolicited report
8: End Point 4 Unsolicited report
9: End Point 5 Unsolicited report
10: End Point 6 Unsolicited report
11: End Point 7 Unsolicited report
12: End Point 8 Unsolicited report
13: End Point 9 Unsolicited report
14: End Point 10 Unsolicited report
15: Random ID enable enables/disables random ID
250: Unsecure / Secure Inclusion Unsecure / Secure Inclusion
1: Lifeline group reserved for the communication with the main controller
2: Basic on/off triggered when the wind gust of the wind gauge exceed the configuration parameter 1 value
3: Basic on/off triggered when the rain rate exceed the configuration parameter 2 value

1: Wind Gauge

Wind Gauge, Wind Gust Top Value

Overview

Wind Gauge, Wind Gust Top Value, if the Wind Gust is Higher than the Parameter Value, a device triggers an Association

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 8800
Default Value 1000

2: Rain Gauge

Rain Rate top value

Overview

If the sensor Rain Rate is higher than the parameter value, a device triggers a association.

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 30000
Default Value 200

3: Wind Gauge

Wind Gust

Overview

0 - if the wind gauge is higher than the parameter No. 1 value, then a device sends basic set = 0x00

1 - if the wind gauge is higher than the parameter No. 1 value, then a device sends basic set =0xff

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 1
Default Value 1

4: Rain Gauge

Rain Rate

Overview

0 - if the rain amount is higher than the parameter No. 2 value, then a device sends basic set = 0x00

1 - if the rain amount is higher than the parameter No. 2 value, then a device sends basic set =0xff

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 1
Default Value 1

5: End Point 1

Unsolicited report

Overview

0 - Unsolicited report disabled

1 - Unsolicited report enabled

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 0 to 1
Default Value 1

6: End Point 2

Unsolicited report

Overview

0 - Unsolicited report disabled

1 - Unsolicited report enabled

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 0 to 1
Default Value 1

7: End Point 3

Unsolicited report

Overview

0 - Unsolicited report disabled

1 - Unsolicited report enabled

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 0 to 1
Default Value 1

8: End Point 4

Unsolicited report

Overview

0 - Unsolicited report disabled

1 - Unsolicited report enabled

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 0 to 1
Default Value 1

9: End Point 5

Unsolicited report

Overview

0 - Unsolicited report disabled

1 - Unsolicited report enabled

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 1
Default Value 1

10: End Point 6

Unsolicited report

Overview

0 - Unsolicited report disabled

1 - Unsolicited report enabled

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 1
Default Value 1

11: End Point 7

Unsolicited report

Overview

0 - Unsolicited report disabled

1 - Unsolicited report enabled

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 0 to 1
Default Value 1

12: End Point 8

Unsolicited report

Overview

0 - Unsolicited report disabled

1 - Unsolicited report enabled

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 0 to 1
Default Value 1

13: End Point 9

Unsolicited report

Overview

0 - Unsolicited report disabled

1 - Unsolicited report enabled

Property Value
Configuration ID config_13_1
Data Type INTEGER
Range 0 to 1
Default Value 1

14: End Point 10

Unsolicited report

Overview

0 - Unsolicited report disabled

1 - Unsolicited report enabled

Property Value
Configuration ID config_14_1
Data Type INTEGER
Range 0 to 1
Default Value 1

15: Random ID enable

enables/disables random ID

Overview

If Random ID is disabled, the Weather Station USB Key can receive data from multiple 433 MHz Sensors on the same Channel. If the Random ID is enabled, the USB Key can receive data from only one sensor on the same channel. If the USB Key does not receive a data from a sensor on a specific channel for more than 2.5 hours, it clears the Random ID of the device and waits for a new ID. If you replace the batteries in the modules, the Random ID will change. If you want that the USB Key accept a module immediately, set the Parameter No. 15 to “0” and in the next step again to “1”.

Property Value
Configuration ID config_15_1
Data Type INTEGER
Range 0 to 1
Default Value 0

250: Unsecure / Secure Inclusion

Unsecure / Secure Inclusion

Overview
  • default Value 0
  • 0 – Unsecure Inclusion
  • 1 – Secure Inclusion

The Weather Station Key supports both, the secure and unsecure inclusion. Even if the controller does not support security command classes, the Key could be included as unsecure and keep all the functionality. By default, the Key includes as unsecure. To include the Key as secure follow the procedure:

  1. Include the Key into the controller
  2. Set the parameter 250 to the value “1”
  3. Enable add/remove mode on main controller,
  4. Hold service button S between 1.5 and 4 seconds to exclude the module
  5. If the exclusion of the module was successful, the LED on the module starts blinking
  6. Unplug the module out of the power supply
  7. enable add/remove mode on main controller
  8. Plug the module into the power supply to star autoinclusion
  9. Now the module should be included as secure

The same procedure is to include the module as unsecure

Property Value
Configuration ID config_250_1
Data Type INTEGER
Range 0 to 1
Default Value 0

1: Lifeline group

reserved for the communication with the main controller

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic on/off

triggered when the wind gust of the wind gauge exceed the configuration parameter 1 value

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Basic on/off

triggered when the rain rate exceed the configuration parameter 2 value

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.