ZTS-110 ZTS-110 Z Wave Thermostat

This describes the Z-Wave device ZTS-110, manufactured by Remotec with the thing type UID of remotec_zts110_00_000.

The ZTS-110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZTS-110 -:

Channel Channel Id Category Item Type
Sensor (temperature) sensor_temperature Temperature Number
Thermostat mode thermostat_mode Temperature Number
Operating State thermostat_state Temperature Number
Setpoint (cooling) thermostat_setpoint Temperature Number
Setpoint (heating) thermostat_setpoint Temperature Number
Thermostat fan mode thermostat_fanmode    
Thermostat fan state thermostat_fanstate    
Battery Level battery-level Battery Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away
15 Full Power
31 Manufacturer Specific

Operating State

Sets the thermostat operating state.

The thermostat_state channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (cooling)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Setpoint (heating)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 13 configuration parameters available in the ZTS-110. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Swing Set Swing value from 1F/.5C to 4F/2.0C Available settings: 1 - 4
2 Differntial Set Differential value from 1F/.5C to 4F/2.0C Available settings: 1 - 4
3 Set Filter Counter Set filter replacement timer from 500 to 4000 hours.
4 Report Filter Counter READ ONLY: Data in hours
5 Scale of Temperature Set Temperature Scale to Farhenheit or Centigrade. DEFAULT =1 Farhenheit
6 Upper Limit of Setpoint A Determines Upper Limit of set point A. Unit in celsius A=(B+2)min (37.0 C)max, Unit in Fahrenheit A=(B+4)min (99.0 F)max
7 Lower Limit of Setpoint B Determines Lower Limit of set point B. Unit in celsius (5.0 C to 35.0 C) Unit in Fahrenheit (41.0 F to 95.0 F)
8 Easy Mode Set Easy Mode 0:DISABLE 1:ENABLED DEFAULT:ENABLED
9 Time Format Configures for 12 or 24 Hour format. Default is 12 Hours.
10 Repeat Basic Set Counter Thermostat sends ‘Basic Set’ command to its association node repeatedly ever X minutes. 0 = Disabled or Set to Enabled Values available 3 to 255.
11 Trigger AUTO report if room temperature is different from last report. 0 = Disabled or set value from 1 to 8 where each number corresponds to 1 Degree F or .5 Degrees Celsius.
12 Sensor temperature calibration. 0 = Disabled or set value from 1 to 10 in 1 degree F increments or -1 to -10 in 1 degree F increments .
13 AUTO report by time interval. 0 = Disabled or set value from 1 to 16 where 1 = .5 hours and each consecutive number increases time by .5 hours.

Parameter 1: Swing

Set Swing value from 1F/.5C to 4F/2.0C Available settings: 1 - 4

Values in the range 1 to 4 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Differntial

Set Differential value from 1F/.5C to 4F/2.0C Available settings: 1 - 4

Values in the range 1 to 4 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Set Filter Counter

Set filter replacement timer from 500 to 4000 hours.

Values in the range 500 to 4000 may be set.

The manufacturer defined default value is 500.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Report Filter Counter

READ ONLY: Data in hours

Values in the range 0 to 9999 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Scale of Temperature

Set Temperature Scale to Farhenheit or Centigrade. DEFAULT =1 Farhenheit

The following option values may be configured -:

Value Description
0 Centigrade
1 Farhenheit

The manufacturer defined default value is 1 (Farhenheit).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Upper Limit of Setpoint A

Determines Upper Limit of set point A. Unit in celsius A=(B+2)min (37.0 C)max, Unit in Fahrenheit A=(B+4)min (99.0 F)max

Values in the range 37 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Lower Limit of Setpoint B

Determines Lower Limit of set point B. Unit in celsius (5.0 C to 35.0 C) Unit in Fahrenheit (41.0 F to 95.0 F)

Values in the range 5 to 95 may be set.

The manufacturer defined default value is 41.

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Parameter 8: Easy Mode

Set Easy Mode 0:DISABLE 1:ENABLED DEFAULT:ENABLED

The following option values may be configured -:

Value Description
0 Easy Mode Disabled
1 Easy Mode Enabled

The manufacturer defined default value is 1 (Easy Mode Enabled).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Time Format

Configures for 12 or 24 Hour format. Default is 12 Hours.

The following option values may be configured -:

Value Description
0 24 Hour Format
1 12 Hour Format

The manufacturer defined default value is 1 (12 Hour Format).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Repeat Basic Set Counter

Thermostat sends ‘Basic Set’ command to its association node repeatedly ever X minutes. 0 = Disabled or Set to Enabled Values available 3 to 255.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Trigger AUTO report if room temperature is different from last report.

0 = Disabled or set value from 1 to 8 where each number corresponds to 1 Degree F or .5 Degrees Celsius.

Values in the range 0 to 8 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Sensor temperature calibration.

0 = Disabled or set value from 1 to 10 in 1 degree F increments or -1 to -10 in 1 degree F increments .

Values in the range -10 to 10 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: AUTO report by time interval.

0 = Disabled or set value from 1 to 16 where 1 = .5 hours and each consecutive number increases time by .5 hours.

Values in the range 0 to 16 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZTS-110 supports 3 association groups.

Group 1: Heat Pump

This group supports 4 nodes.

Group 2: Compressor

This group supports 4 nodes.

Group 3: Controller Update

This group supports 1 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SENSOR_MULTILEVEL_V1  
COMMAND_CLASS_THERMOSTAT_MODE_V1  
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1  
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1  
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1  
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  