ZFM-80 Fixture Switch Module

This describes the Z-Wave device ZFM-80, manufactured by Remotec with the thing type UID of remotec_zfm80_00_000.

Fixture Switch Module

Overview

The ZFM-80US Fixture Switch Module is a Z-Wave enabled device and fully compatible with any Z-Wave enabled network. It allows remote On/Off control of specified resistive household appliance. Each fixture switch module is designed to act as a repeater, which will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacle and radio dead spots.

Key Features:

- High output power

- Remote ON/OFF control via the Z-Wave controller

- Manual ON/OFF control with the front panel push button

- Support External ON/OFF key connects to the module

- Advanced function

Conditional trigger for “Fail Safe Installation”

- Support Network Wide Inclusion (NWI) and Explore Frames

- Screw terminals for wires connection

- Flexible mounting structure - mount inside gang box or any place

Inclusion Information

Include or exclude the Fixture Switch Module from the existing ZWave home control network with your primary controller.

- Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.

- When prompted by your primary controller, click once on the PROG button or external switch.

- The primary controller should indicate that the action was successful. If the controller indicates the action was unsuccessful, please repeat the procedure.

- Once the Fixture Switch Module is part of the network, the same basic procedure is used to add the Fixture Switch Module to groups or scenes. Refer to the primary controller’s instructions for details.

Channels

The following table summarises the channels available for the ZFM-80 Fixture Switch Module.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the ZFM-80 Fixture Switch Module. Detailed information on each parameter can be found below.

Parameter Description
1: ExternalSwitchType Set External switch type Definitions
2: Timeout Set timeout period
3: NodeIdNumber Configure Node ID number for Z-Wave command source
4: OutputStatus Set relay output status if timeout period has been reached
1: AssociationGroup  

1: ExternalSwitchType

Set External switch type Definitions

Overview

ZFM-80 provides an option to user that can add an external switch to control the On/Off function. ZFM-80US can be placed into the switch box with external wall switch cover. User can configure the external switch type through the configuration command

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 3
Options Disable (0)      
  TypeA (1)      
  TypeB (2)      
  TypeC (3)      
  TypeD (4)      

2: Timeout

Set timeout period

Overview

ZFM-80US provides an advanced function “Conditional trigger for Fail Safe Installation”. It can turn on or turn off the relay if ZFM-80US has not received any Z-Wave commands from a specified Z-Wave Node ID and within a specified period. For example: Z-Wave gateway can monitor a Z-Wave device status and power on equipment if this Z-Wave device is out of service.

(default value is 0 [function disabled])

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 240
Default Value 0

3: NodeIdNumber

Configure Node ID number for Z-Wave command source

Overview

ZFM-80US provides an advanced function “Conditional trigger for Fail Safe Installation”. It can turn on or turn off the relay if ZFM-80US has not received any Z-Wave commands from a specified Z-Wave Node ID and within a specified period. For example: Z-Wave gateway can monitor a Z-Wave device status and power on equipment if this Z-Wave device is out of service.

(default value is 0 [function disabled])

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 232
Default Value 0

4: OutputStatus

Set relay output status if timeout period has been reached

Overview

 ZFM-80US provides an advanced function “Conditional trigger for Fail Safe Installation”. It can turn on or turn off the relay if ZFM-80US has not received any Z-Wave commands from a specified Z-Wave Node ID and within a specified period. For example: Z-Wave gateway can monitor a Z-Wave device status and power on equipment if this Z-Wave device is out of service.

1 = turn on relay

0 = turn off relay

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 1
Default Value 0

1: AssociationGroup

Overview

Used to report the relay on/off status to specify nodes with ZFM-80US predefined association group once the relay state has been changed.

Property Value
Configuration ID group_1
Data Type TEXT
Range to