ZXT-120 AC IR Remote

This describes the Z-Wave device ZXT-120, manufactured by Remotec with the thing type UID of remotec_zxt120_00_000.

AC IR Remote

Channels

The following table summarises the channels available for the ZXT-120 AC IR Remote.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Thermostat mode thermostat_mode remotec_zxt120_00_000_thermostat_mode Temperature Number
Setpoint (cooling) thermostat_setpoint_cooling thermostat_setpoint Temperature Number
Setpoint (heating) thermostat_setpoint_heating thermostat_setpoint Temperature Number
Thermostat fan mode thermostat_fanmode remotec_zxt120_00_000_thermostat_fanmode Temperature Number
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (cooling)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZXT-120 AC IR Remote. Detailed information on each parameter can be found below.

Parameter Description
25: Indicate a location for IR code learning and start learning  
26: Learning status register (Read Only)  
27: IR code number for built-in code library  
28: External IR Emitter power level  
32: Surround IR control  
33: AC function Swing control  
35: Learn location status. Bitmask. (Read Only)  
37: Sensor temperature compensation  

25: Indicate a location for IR code learning and start learning

Property Value
Configuration ID config_25_1
Data Type INTEGER
Range 0 to 22
Default Value 1

26: Learning status register (Read Only)

Property Value
Configuration ID config_26_1
Data Type INTEGER
Range 0 to 4
Default Value 0

27: IR code number for built-in code library

Property Value
Configuration ID config_27_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

28: External IR Emitter power level

Property Value      
Configuration ID config_28_1      
Data Type INTEGER   Default Value 255
Options Normal power mode (0)      
  High power mode (255)      

32: Surround IR control

Property Value      
Configuration ID config_32_1      
Data Type INTEGER   Default Value -1
Options Enable Surround IR Emitters (-1)      
  Disable Surround IR Emitters (0)      

33: AC function Swing control

Property Value      
Configuration ID config_33_1      
Data Type INTEGER   Default Value 1
Options Swing Off (0)      
  Swing Auto (1)      

35: Learn location status. Bitmask. (Read Only)

Property Value
Configuration ID config_35_4
Data Type INTEGER
Range 0 to 65535
Default Value 0

37: Sensor temperature compensation

Property Value
Configuration ID config_37_1
Data Type INTEGER
Range -5 to 5
Default Value 0

Did you spot an error in the above definition or want to improve the content? You can edit the database here.