The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

CT110 Thermostat

This describes the Z-Wave device CT110, manufactured by Radio Thermostat Company of America (RTC) with the thing type UID of rtc_ct110_00_000.

The CT110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the CT110 -:

Channel Channel Id Category Item Type
Sensor (temperature) sensor_temperature Temperature Number
Sensor (relative humidity) sensor_relhumidity Humidity Number
Thermostat mode thermostat_mode Temperature Number
Operating State thermostat_state Temperature Number
Setpoint (furnace) thermostat_setpoint Temperature Number
Setpoint (dry air) thermostat_setpoint Temperature Number
Setpoint (heating) thermostat_setpoint Temperature Number
Setpoint (cooling) thermostat_setpoint Temperature Number
Thermostat fan mode thermostat_fanmode    
Thermostat fan state thermostat_fanstate    
Battery Level battery-level Battery Number
Clock Time Offset time_offset Temperature Number
Sensor (temperature) 1 sensor_temperature1 Temperature Number
Sensor (relative humidity) 1 sensor_relhumidity1 Humidity Number
Thermostat mode 1 thermostat_mode1 Temperature Number
Operating State 1 thermostat_state1 Temperature Number
Setpoint (furnace) 1 thermostat_setpoint1 Temperature Number
Setpoint (dry air) 1 thermostat_setpoint1 Temperature Number
Setpoint (heating) 1 thermostat_setpoint1 Temperature Number
Setpoint (cooling) 1 thermostat_setpoint1 Temperature Number
Thermostat fan mode 1 thermostat_fanmode1    
Thermostat fan state 1 thermostat_fanstate1    
Battery Level battery-level Battery Number
Clock Time Offset 1 time_offset1 Temperature Number
Sensor (temperature) 2 sensor_temperature2 Temperature Number
Sensor (relative humidity) 2 sensor_relhumidity2 Humidity Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away
15 Full Power
31 Manufacturer Specific

Operating State

Sets the thermostat operating state.

The thermostat_state channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (furnace)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Setpoint (dry air)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Setpoint (heating)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Setpoint (cooling)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel supports the Number item and is in the Temperature category.

Sensor (temperature) 1

Indicates the current temperature.

The sensor_temperature1 channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Sensor (relative humidity) 1

Indicates the current relative humidity.

The sensor_relhumidity1 channel supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode 1

Sets the thermostat.

The thermostat_mode1 channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away
15 Full Power
31 Manufacturer Specific

Operating State 1

Sets the thermostat operating state.

The thermostat_state1 channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (furnace) 1

Sets the thermostate setpoint.

The thermostat_setpoint1 channel supports the Number item and is in the Temperature category.

Setpoint (dry air) 1

Sets the thermostate setpoint.

The thermostat_setpoint1 channel supports the Number item and is in the Temperature category.

Setpoint (heating) 1

Sets the thermostate setpoint.

The thermostat_setpoint1 channel supports the Number item and is in the Temperature category.

Setpoint (cooling) 1

Sets the thermostate setpoint.

The thermostat_setpoint1 channel supports the Number item and is in the Temperature category.

Thermostat fan mode 1

Channel type information on this channel is not found.

Thermostat fan state 1

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level1 channel supports the Number item and is in the Battery category.

Clock Time Offset 1

Provides the current time difference for the devices time.

The time_offset1 channel supports the Number item and is in the Temperature category.

Sensor (temperature) 2

Indicates the current temperature.

The sensor_temperature2 channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Sensor (relative humidity) 2

Indicates the current relative humidity.

The sensor_relhumidity2 channel supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The device has no configuration parameters configured.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V5| | | COMMAND_CLASS_THERMOSTAT_MODE_V2| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V2| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_CLOCK_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_INDICATOR_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V5| | | COMMAND_CLASS_THERMOSTAT_MODE_V2| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V2| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_CLOCK_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_INDICATOR_V1| |

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.