CT32 Z-Wave Thermostat

This describes the Z-Wave device CT32, manufactured by Radio Thermostat Company of America (RTC) with the thing type UID of rtc_ct32_00_000.

CT32 product image

The CT32 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the CT32 -:

Channel Channel Id Category Item Type
Sensor (temperature) sensor_temperature Temperature Number
Sensor (relative humidity) sensor_relhumidity Humidity Number
Thermostat mode thermostat_mode Temperature Number
Operating State thermostat_state Temperature Number
Setpoint (furnace) thermostat_setpoint Temperature Number
Setpoint (dry air) thermostat_setpoint Temperature Number
Setpoint (heating) thermostat_setpoint Temperature Number
Setpoint (cooling) thermostat_setpoint Temperature Number
Thermostat fan mode thermostat_fanmode    
Thermostat fan state thermostat_fanstate    
Battery Level battery-level Battery Number
Clock Time Offset time_offset Temperature Number
Sensor (temperature) 1 sensor_temperature1 Temperature Number
Sensor (relative humidity) 1 sensor_relhumidity1 Humidity Number
Thermostat mode 1 thermostat_mode1 Temperature Number
Operating State 1 thermostat_state1 Temperature Number
Setpoint (furnace) 1 thermostat_setpoint1 Temperature Number
Setpoint (dry air) 1 thermostat_setpoint1 Temperature Number
Setpoint (heating) 1 thermostat_setpoint1 Temperature Number
Setpoint (cooling) 1 thermostat_setpoint1 Temperature Number
Thermostat fan mode 1 thermostat_fanmode1    
Thermostat fan state 1 thermostat_fanstate1    
Battery Level battery-level Battery Number
Clock Time Offset 1 time_offset1 Temperature Number
Sensor (temperature) 2 sensor_temperature2 Temperature Number
Sensor (relative humidity) 2 sensor_relhumidity2 Humidity Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away
15 Full Power
31 Manufacturer Specific

Operating State

Sets the thermostat operating state.

The thermostat_state channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (furnace)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Setpoint (dry air)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Setpoint (heating)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Setpoint (cooling)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel supports the Number item and is in the Temperature category.

Sensor (temperature) 1

Indicates the current temperature.

The sensor_temperature1 channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Sensor (relative humidity) 1

Indicates the current relative humidity.

The sensor_relhumidity1 channel supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode 1

Sets the thermostat.

The thermostat_mode1 channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away
15 Full Power
31 Manufacturer Specific

Operating State 1

Sets the thermostat operating state.

The thermostat_state1 channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (furnace) 1

Sets the thermostate setpoint.

The thermostat_setpoint1 channel supports the Number item and is in the Temperature category.

Setpoint (dry air) 1

Sets the thermostate setpoint.

The thermostat_setpoint1 channel supports the Number item and is in the Temperature category.

Setpoint (heating) 1

Sets the thermostate setpoint.

The thermostat_setpoint1 channel supports the Number item and is in the Temperature category.

Setpoint (cooling) 1

Sets the thermostate setpoint.

The thermostat_setpoint1 channel supports the Number item and is in the Temperature category.

Thermostat fan mode 1

Channel type information on this channel is not found.

Thermostat fan state 1

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level1 channel supports the Number item and is in the Battery category.

Clock Time Offset 1

Provides the current time difference for the devices time.

The time_offset1 channel supports the Number item and is in the Temperature category.

Sensor (temperature) 2

Indicates the current temperature.

The sensor_temperature2 channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Sensor (relative humidity) 2

Indicates the current relative humidity.

The sensor_relhumidity2 channel supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the CT32. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Temperature Reporting Threshold Sets the reporting threshold for changes in ambient temperature.
3 Utility Lock Enable/Disable Enables or Disables the Utility Lock.
5 Humidity Reporting Threshold Sets the reporting threshold for changes in humidity.
6 Auxiliary/Emergency Enables or Disables the Aux / Emergency Heat.
7 Swing Temperature Sets the swing threshold before turning on / off HVAC.
8 Thermostat Diff Temperature Set’s the differential temperature for multi-stage HVAC systems.
9 Thermostat Recovery Mode This parameter defines the thermostat recovery mode.
11 Simple UI Mode Enable/Disable Enables or Disables Simple UI Mode
12 Multicast Enable/Disable If set to 0, multicast is disabled, if set to 1, will enable the multicast.

Parameter 1: Temperature Reporting Threshold

Sets the reporting threshold for changes in ambient temperature. The Temperature Reporting Threshold Configuration Set Command sets the reporting threshold for changes in the ambient temperature as detected by the thermostat. The following option values may be configured -:

Value Description
0 Disabled
1 0.5F
2 1.0F
3 1.5F
4 2.0F

The manufacturer defined default value is 2 (1.0F).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 3: Utility Lock Enable/Disable

Enables or Disables the Utility Lock. The Utility Lock Configuration Set command enables or disables the utility lock. If the utility lock is enabled, the setpoint cannot be modified directly via the thermostat screen. The following option values may be configured -:

Value Description
0 Utility lock disable
1 Utility lock enable

The manufacturer defined default value is 0 (Utility lock disable).

This parameter has the configuration ID config_3_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 5: Humidity Reporting Threshold

Sets the reporting threshold for changes in humidity. The Humidity Threshold Configuration Set Command sets the reporting threshold for changes in the relative humidity as detected by the thermostat. The following option values may be configured -:

Value Description
0 Disabled
1 3%RH
2 5%RH
3 10%RH

The manufacturer defined default value is 2 (5%RH).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Auxiliary/Emergency

Enables or Disables the Aux / Emergency Heat. The Auxiliary/Emergency configuration command enables or disables auxiliary / emergency heating in the thermostat. Auxiliary / emergency heating is only available if the thermostat is configured in heat pump mode and with at least one stage of auxiliary h The following option values may be configured -:

Value Description
0 Auxiliary/Emergency heat disable
1 Auxiliary/Emergency heat enable

The manufacturer defined default value is 0 (Auxiliary/Emergency heat disable).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Swing Temperature

Sets the swing threshold before turning on / off HVAC. The Thermostat Swing Temperature configuration command sets swing temperature on the thermostat. The swing temperature is applied to the setpoint to determine when the thermostat will turn on the HVAC system. The following option values may be configured -:

Value Description
1 0.0F
2 1F
3 1.5F
4 2F
5 2.5F
6 3F
7 3.5F
8 4F

The manufacturer defined default value is 2 (1F).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Thermostat Diff Temperature

Set’s the differential temperature for multi-stage HVAC systems. The Thermostat Differential Temperature configuration command sets the differential temperature for multi-stage HVAC systems. The differential temperature delta defines when the thermostat will turn on additional stages. Values in the range 4 to 3084 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: Thermostat Recovery Mode

This parameter defines the thermostat recovery mode.

The following option values may be configured -:

Value Description
1 Recovery Mode is set to fast.
2 Recovery Mode is set to economy.

The manufacturer defined default value is 2 (Recovery Mode is set to economy.).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 11: Simple UI Mode Enable/Disable

Enables or Disables Simple UI Mode If set to 0, Simple UI Mode is disabled, if set to 1, will enable the Simple UI Mode. The following option values may be configured -:

Value Description
0 Simple UI Mode Disabled
1 Simple UI Mode Enabled

The manufacturer defined default value is 1 (Simple UI Mode Enabled).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Multicast Enable/Disable

If set to 0, multicast is disabled, if set to 1, will enable the multicast.

The following option values may be configured -:

Value Description
0 Multicast Disabled
1 Function is enabled.

The manufacturer defined default value is 0 (Multicast Disabled).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The CT32 supports 1 association group.

Group 1: Group 1

This group supports 2 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V5| | | COMMAND_CLASS_THERMOSTAT_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_CLOCK_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_INDICATOR_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V5| | | COMMAND_CLASS_THERMOSTAT_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_CLOCK_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_INDICATOR_V1| |

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_V1  