CT100 Plus Z-Wave Thermostat

This describes the Z-Wave device CT100 Plus, manufactured by Radio Thermostat Company of America (RTC) with the thing type UID of rtc_ct100plus_00_000.

Z-Wave Thermostat

Channels

The following table summarises the channels available for the CT100 Plus Z-Wave Thermostat.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Thermostat mode thermostat_mode rtc_ct100plus_00_000_thermostat_mode Temperature Number
Thermostat Operating State thermostat_state thermostat_state Temperature Number
Setpoint (heating) thermostat_setpoint_heating thermostat_setpoint Temperature Number
Setpoint (cooling) thermostat_setpoint_cooling thermostat_setpoint Temperature Number
Setpoint (dry air) thermostat_setpoint_dry_air thermostat_setpoint Temperature Number
Setpoint (furnace) thermostat_setpoint_furnace thermostat_setpoint Temperature Number
Thermostat fan mode thermostat_fanmode rtc_ct100plus_00_000_thermostat_fanmode Temperature Number
Thermostat fan state thermostat_fanstate rtc_ct100plus_00_000_thermostat_fanstate Temperature Number
  battery-level system.battery-level    
Clock Time Offset time_offset time_offset Temperature Number
Sensor (relative humidity) 1 sensor_relhumidity1 sensor_relhumidity Humidity Number
Sensor (temperature) 1 sensor_temperature1 sensor_temperature Temperature Number
Thermostat mode 1 thermostat_mode1 rtc_ct100plus_00_000_thermostat_mode Temperature Number
Thermostat Operating State 1 thermostat_state1 thermostat_state Temperature Number
Setpoint (heating) 1 thermostat_setpoint_heating1 thermostat_setpoint Temperature Number
Setpoint (cooling) 1 thermostat_setpoint_cooling1 thermostat_setpoint Temperature Number
Setpoint (dry air) 1 thermostat_setpoint_dry_air1 thermostat_setpoint Temperature Number
Setpoint (furnace) 1 thermostat_setpoint_furnace1 thermostat_setpoint Temperature Number
Thermostat fan mode 1 thermostat_fanmode1 rtc_ct100plus_00_000_thermostat_fanmode Temperature Number
Thermostat fan state 1 thermostat_fanstate1 rtc_ct100plus_00_000_thermostat_fanstate Temperature Number
Clock Time Offset 1 time_offset1 time_offset Temperature Number
Sensor (relative humidity) 2 sensor_relhumidity2 sensor_relhumidity Humidity Number
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (cooling)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (dry air)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (furnace)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Sensor (temperature) 1

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating) 1

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (cooling) 1

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (dry air) 1

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (furnace) 1

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Clock Time Offset 1

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Sensor (temperature) 2

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the CT100 Plus Z-Wave Thermostat. Detailed information on each parameter can be found below.

Parameter Description
1: Temperature Reporting Threshold Reporting threshold for changes in the ambient temperature
2: HVAC Settings Configured HVAC settings
4: Power Status C-Wire / Battery Status
5: Humidity Reporting Threshold Reporting threshold for changes in the relative humidity
6: Auxiliary/Emergency Enables or disables auxiliary / emergency heating
7: Thermostat Swing Temperature Variance allowed from setpoint to engage HVAC
8: Thermostat Diff Temperature Configures additional stages
9: Thermostat Recovery Mode Fast or Economy recovery mode
10: Temperature Filter Lower Bound Unit Upper/Lower bounds for thermostat temperature reporting
10: Temperature Filter Upper Bound Upper/Lower bounds for thermostat temperature reporting
10: Temperature Filter Upper Bound Unit Upper/Lower bounds for thermostat temperature reporting
10: Temperature Filter Lower Bound Upper/Lower bounds for thermostat temperature reporting
11: Simple UI Mode Simple mode enable/disable
12: Multicast Enable or disables Multicast
3: Utility Lock Enable/Disable Prevents setpoint changes at thermostat
1: Group 1 Send report about Thermostat Mode, Thermostat Operating State, Fan Mode, Fan State, Setpoi…

1: Temperature Reporting Threshold

Reporting threshold for changes in the ambient temperature

Overview

This value determines the reporting threshold when association reporting is enabled. Unsupported values will be ignored.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 2
Options Disabled (0)      
  0.5° F (1)      
  1.0° F (2)      
  1.5° F (3)      
  2.0° F (4)      

2: HVAC Settings

Configured HVAC settings

Overview

Byte 1 = HVAC Setup: Normal (0x01) or Heat Pump (0x02)
Byte 2 = Aux Setup (Gas (0x01) or Electric (0x02)) & Number of Auxiliary Stages (Heat Pump)/Number of Heat Stages (Normal)
Byte 3 = Number of Heat Pump Stages
Byte 4 = Number of Cool Stages

Property Value
Configuration ID config_2_4
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

4: Power Status

C-Wire / Battery Status

Overview

If 0x01, the thermostat is powered by a C-wire. If 0x02, the thermostat is powered by batteries.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 255
Default Value 0

5: Humidity Reporting Threshold

Reporting threshold for changes in the relative humidity

Overview

This value determines the reporting threshold when association reporting is enabled. Unsupported values will be ignored.

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  3% RH (1)      
  5% RH (2)      
  10% RH (3)      

6: Auxiliary/Emergency

Enables or disables auxiliary / emergency heating

Overview

If set to 0, auxiliary / emergency heat is disabled, all other values, 1-255, will enable the auxiliary / emergency heat. This can only be enabled when the thermostat is set to Heat Pump mode.

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options Auxiliary/Emergency heat disabled (0)      
  Auxiliary/Emergency heat enabled (1)      

7: Thermostat Swing Temperature

Variance allowed from setpoint to engage HVAC

Overview

The thermostat swing temperature is in units of 0.5 degrees Fahrenheit.

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 2
Options 0.5° F (1)      
  1.0° F (2)      
  1.5° F (3)      
  2.0° F (4)      
  2.5° F (5)      
  3.0° F (6)      
  3.5° F (7)      
  4.0° F (8)      

8: Thermostat Diff Temperature

Configures additional stages

Overview

Sets the differential temperature for multi-stage HVAC systems. The differential temperature delta defines when the thermostat will turn on additional stages. This command configures both the heat and cool differential temperatures.

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 4
Options 2.0° F (4)      
  4.0° F (8)      
  6.0° F (12)      

9: Thermostat Recovery Mode

Fast or Economy recovery mode

Overview

The Thermostat Recovery Mode can be either fast (1) or economy (2).

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 2
Options Fast recovery mode (1)      
  Economy recovery mode (2)      

10: Temperature Filter Lower Bound Unit

Upper/Lower bounds for thermostat temperature reporting

Overview

Specifies unit for lower bound parameter. If set to 1, lower bound is Celsius. If set to 9, lower bound is Fahrenheit.

Property Value      
Configuration ID config_10_4      
Data Type INTEGER   Default Value 1
Options Celsius (1)      
  Fahreheit (9)      

10: Temperature Filter Upper Bound

Upper/Lower bounds for thermostat temperature reporting

Overview

The thermostat will report ambient temperature changes for temperature values greater than the upper bound. This field must be between 0F and 124F. By default, this value is 0F (report all temperature changes).

Property Value
Configuration ID config_10_4_000000FF
Data Type INTEGER
Range 0 to 124
Default Value 0

10: Temperature Filter Upper Bound Unit

Upper/Lower bounds for thermostat temperature reporting

Overview

Specifies unit for upper bound parameter. If set to 1, upper bound is Celsius. If set to 9, upper bound is Fahrenheit.

Property Value      
Configuration ID config_10_4_0000FF00      
Data Type INTEGER   Default Value 9
Options Celsius (0)      
  Fahrenheit (9)      

10: Temperature Filter Lower Bound

Upper/Lower bounds for thermostat temperature reporting

Overview

The thermostat will report ambient temperature changes for temperature values less than the lower bound. This field must be between 0F and 124F. By default, this value is 124F (report all temperature changes).

Property Value
Configuration ID config_10_4_00FF0000
Data Type INTEGER
Range 0 to 124
Default Value 124

11: Simple UI Mode

Simple mode enable/disable

Overview

If the value is set to 0 then Normal Mode is enabled. If the value is set to 1 then Simple Mode is enabled.

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 1
Options Normal mode enabled (0)      
  Simple mode enabled (1)      

12: Multicast

Enable or disables Multicast

Overview

If set to 0, Multicast is disabled. If set to 1, Multicast is enabled.

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 0
Options Multicast disabled (0)      
  Multicast enabled (1)      

3: Utility Lock Enable/Disable

Prevents setpoint changes at thermostat

Overview

If set to 0, the utility lock is disabled, all other values, 1-255, will enable the utility lock. This will prevent changes to the setpoint at the thermostat screen.

Property Value      
Configuration ID config_3_1_wo      
Data Type INTEGER   Default Value 0
Options Utility lock disabled (0)      
  Utility lock enabled (1)      

1: Group 1

Send report about Thermostat Mode, Thermostat Operating State, Fan Mode, Fan State, Setpoint, Sensor Multilevel

Property Value
Configuration ID group_1
Data Type TEXT
Range to