CT30 Z-Wave Thermostat
This describes the Z-Wave device CT30, manufactured by Radio Thermostat Company of America (RTC) with the thing type UID of rtc_ct30_00_000
.
Z-Wave Thermostat
Channels
The following table summarises the channels available for the CT30 Z-Wave Thermostat.
Channel | Channel Id | Channel Type UID | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number |
Thermostat mode | thermostat_mode | rtc_ct30_00_000_thermostat_mode | Temperature | Number |
Thermostat Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (cooling) | thermostat_setpoint_cooling | thermostat_setpoint | Temperature | Number |
Setpoint (heating) | thermostat_setpoint_heating | thermostat_setpoint | Temperature | Number |
Thermostat fan mode | thermostat_fanmode | rtc_ct30_00_000_thermostat_fanmode | Temperature | Number |
battery-level | system.battery-level | |||
Clock Time Offset | time_offset | time_offset | Temperature | Number |
Sensor (temperature)
Scale
Select the scale for temperature readings
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_scale | |||
Data Type | TEXT | Default Value | 0 | |
Options | Celsius (0) | |||
Fahrenheit (1) |
Setpoint (cooling)
Scale
Select the scale to use for setpoints.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_scale | |||
Data Type | TEXT | Default Value | 0 | |
Options | Celsius (0) | |||
Fahrenheit (1) |
Setpoint (heating)
Scale
Select the scale to use for setpoints.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_scale | |||
Data Type | TEXT | Default Value | 0 | |
Options | Celsius (0) | |||
Fahrenheit (1) |
Clock Time Offset
Automatic Update Offset
The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_offset | |||
Data Type | INTEGER | |||
Range | 10 to 600 | Default Value | 60 | |
Options | Disable Auto Update (0) |
Device Configuration
The following table provides a summary of the configuration parameters available in the CT30 Z-Wave Thermostat. Detailed information on each parameter can be found below.
Parameter | Description |
---|---|
1: Temperature Reporting Threshold | Sets the reporting threshold for changes in the ambient temperature as detected by the the… |
3: Utility Lock Enable/Disable | The Utility Lock Configuration Set command enables or disables the utility lock. If the ut… |
5: Humidity Reporting Threshold | The Humidity Threshold Configuration Set Command sets the reporting threshold for changes … |
6: Auxiliary/Emergency | The Auxiliary/Emergency configuration command enables or disables auxiliary / emergency he… |
7: Thermostat Swing Temperature | The Thermostat Swing Temperature configuration command sets swing temperature on the therm… |
8: Thermostat Diff Temperature | The Thermostat Differential Temperature configuration command sets the differential temper… |
1: Group 1 |
1: Temperature Reporting Threshold
Sets the reporting threshold for changes in the ambient temperature as detected by the thermostat.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_1_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disabled (0) | |||
0.5° (1) | ||||
1.0° (2) | ||||
1.5° (3) | ||||
2.0° (4) |
3: Utility Lock Enable/Disable
The Utility Lock Configuration Set command enables or disables the utility lock. If the utility lock is enabled, the setpoint cannot be modified directly via the thermostat screen.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_3_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Utility lock disable (0) | |||
Utility lock enable (1) |
5: Humidity Reporting Threshold
The Humidity Threshold Configuration Set Command sets the reporting threshold for changes in the relative humidity as detected by the thermostat.
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_5_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disabled (0) | |||
3% RH (1) | ||||
5% RH (2) | ||||
10%RH (3) |
6: Auxiliary/Emergency
The Auxiliary/Emergency configuration command enables or disables auxiliary / emergency heating in the thermostat. Auxiliary / emergency heating is only available if the thermostat is configured in heat pump mode and with at least one stage of auxiliary h
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_6_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Auxiliary/Emergency heat disabled (0) | |||
Auxiliary/Emergency heat enable (1) |
7: Thermostat Swing Temperature
The Thermostat Swing Temperature configuration command sets swing temperature on the thermostat. The swing temperature is applied to the setpoint to determine when the thermostat will turn on the HVAC system. If the thermostat is heating, the swing temper
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_7_1 | |||
Data Type | INTEGER | Default Value | 1 | |
Options | 0.05F (1) | |||
0.1F (2) | ||||
4F (8) |
8: Thermostat Diff Temperature
The Thermostat Differential Temperature configuration command sets the differential temperature for multi-stage HVAC systems. The differential temperature delta defines when the thermostat will turn on additional stages. There are two differential tempera
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_8_1 | |||
Data Type | INTEGER | Default Value | 4 | |
Options | 2.0 F (4) | |||
4.0 F (8) | ||||
6.0 F (12) |
1: Group 1
Property | Value |
---|---|
Configuration ID | group_1 |
Data Type | TEXT |
Range | to |
Did you spot an error in the above definition or want to improve the content? You can edit the database here.