The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

BE369 Keypad Deadbolt

This describes the Z-Wave device BE369, manufactured by Allegion with the thing type UID of schlage_be369_00_000.

BE369 product image

The BE369 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

Schlage BE369 Keypad Door Lock -

Shares same hardware as FE599 lock (lever version).

Inclusion Information

  1. When prompted, follow the lock’s enrollment process:
  2. Enter your 6-digit programming code
  3. Wait for the device to beep three times
  4. Press the Schlage button
  5. Press 0
  6. The Schlage button will blink three times to confirm

Exclusion Information

  1. When prompted, follow the lock’s removal process:
  2. Enter your 6-digit programming code
  3. Wait for the device to beep three times
  4. Press the Schlage button
  5. Press 0
  6. The Schlage button will blink three times to confirm

Wakeup Information

Unknown

Channels

The following table summarises the channels available for the BE369 -:

Channel Channel Id Category Item Type
Door Lock lock_door Door Switch
Alarm alarm_general Door Switch
Alarm (access) notification_access_control   Number
Alarm (number) alarm_number    
Battery Level battery-level Battery Number

Door Lock

Lock and unlock the door.

The lock_door channel supports the Switch item and is in the Door category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Alarm (access)

Access Control.

The notification_access_control channel supports the Number item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Number item type -:

Value Label
0 Previous Events cleared
1 Manual Lock Operation
2 Manual Unlock Operation
3 RF Lock Operation
4 RF Unlock Operation
5 Keypad Lock Operation
6 Keypad Unlock Operation
7 Manual Not Fully Locked Operation
8 RF Not Fully Locked Operation
9 Auto Lock Locked Operation
10 Auto Lock Not Fully Operation
11 LockJammed
12 All user codes deleted
13 Single user code deleted
14 New user code added
15 New user code not added due to duplicate code
16 Keypad temporary disabled
17 Keypad busy
18 New Program code Entered- Unique code for lock configuration
19 Manually Enter user Access code exceeds code limit
20 Unlock by RF with invalid user code
21 Locked by RF with invalid user code
22 Window/Door is open
23 Window/Door is closed
64 Barrier performing initialization process
65 Barrier operation (Open / Close) force has been exceeded
66 Barrier motor has exceeded manufacturer’s operational time limit
67 Barrier operation has exceeded physical mechanical limits
68 Barrier unable to perform requested operation due to UL requirements
69 Barrier Unattended operation has been disabled per UL requirements
70 Barrier failed to perform Requested operation, device malfunction
71 Barrier Vacation Mode
72 Barrier Safety Beam Obstacle
73 Barrier Sensor Not Detected / Supervisory Error
74 Barrier Sensor Low Battery Warning
75 Barrier detected short in WallStation wires
76 Barrier associated with non-Z-wave remote control

Alarm (number)

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the BE369. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Beeper Turn key beep on or off for keypad
  Lock Timeout Sets the time after which the door will auto lock

Parameter 3: Beeper

Turn key beep on or off for keypad Turn key beep on or off for keypad The following option values may be configured -:

Value Description
0 Disable Beeper
1 Enable Beeper

The manufacturer defined default value is 1 (Enable Beeper).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The BE369 supports 1 association group.

Group 1: Alarm Reports

This group supports 2 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_DOOR_LOCK_V1  
COMMAND_CLASS_USER_CODE_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  
COMMAND_CLASS_SECURITY_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.