BE468 Touchscreen Deadbolt
This describes the Z-Wave device BE468, manufactured by Allegion with the thing type UID of schlage_be468_00_000
.
Touchscreen Deadbolt
Channels
The following table summarises the channels available for the BE468 Touchscreen Deadbolt.
Channel | Channel Id | Channel Type UID | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Alarm (access) | alarm_access | alarm_access | Door | Switch |
Alarm (power) | alarm_power | alarm_power | Door | Switch |
Alarm (system) | alarm_system | alarm_system | Switch | |
battery-level | system.battery-level |
Device Configuration
The following table provides a summary of the configuration parameters available in the BE468 Touchscreen Deadbolt. Detailed information on each parameter can be found below.
Parameter | Description |
---|---|
3: Beeper | Audio feedback when keypad pressed during normal operation |
4: Vacation Mode | Prevents all user codes from unlocking the deadbolt |
5: Lock & Leave | Press the Schlage button to lock the deadbolt |
15: Auto Lock | Automatically locks 30 seconds after unlocking |
16: User Code PIN Length | User codes can be 4-8 digits. Changing length will delete all existing codes. |
1: Group 1 |
3: Beeper
Audio feedback when keypad pressed during normal operation
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_3_1 | |||
Data Type | INTEGER | Default Value | 255 | |
Options | Disable (0) | |||
Enable (255) |
4: Vacation Mode
Prevents all user codes from unlocking the deadbolt
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_4_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disable (0) | |||
Enable (255) |
5: Lock & Leave
Press the Schlage button to lock the deadbolt
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_5_1 | |||
Data Type | INTEGER | Default Value | 255 | |
Options | Disable (0) | |||
Enable (255) |
15: Auto Lock
Automatically locks 30 seconds after unlocking
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_15_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disable (0) | |||
Enable (255) |
16: User Code PIN Length
User codes can be 4-8 digits. Changing length will delete all existing codes.
Property | Value |
---|---|
Configuration ID | config_16_1 |
Data Type | INTEGER |
Range | 4 to 8 |
Default Value | 4 |
1: Group 1
Property | Value |
---|---|
Configuration ID | group_1 |
Data Type | TEXT |
Range | to |
Did you spot an error in the above definition or want to improve the content? You can edit the database here.