Siren Alarm Siren Alarm

This describes the Z-Wave device Siren Alarm, manufactured by Shenzhen Neo Electronics Co., Ltd with the thing type UID of shenzhen_sirenalarm_00_000.

Siren Alarm product image

The Siren Alarm supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the Siren Alarm -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Alarm alarm_general Door Switch
Battery Level battery-level Battery Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the Siren Alarm. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Configure Alarm music volume Configure Alarm music volume
2 Alarm music duration time Alarm music duration time
3 Door bell music duration time Door bell music duration time
4 Door bell music volume Door bell music volume
5 Alarm music index Alarm music index
6 Door bell music index Door bell music index
7 Default Siren on mode Default Siren on mode

Parameter 1: Configure Alarm music volume

Configure Alarm music volume

Values in the range 1 to 3 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Alarm music duration time

Alarm music duration time

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Door bell music duration time

Door bell music duration time

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Door bell music volume

Door bell music volume

Values in the range 1 to 3 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Alarm music index

Alarm music index

Values in the range 1 to 10 may be set.

The manufacturer defined default value is 9.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Door bell music index

Door bell music index

Values in the range 1 to 10 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Default Siren on mode

Default Siren on mode This parameter defines the default music index, volume and duration time for siren on.

This parameter can be selected between ALARM MUSIC and DOOR BELL music.

The settings for ALARM MUSIC defines by Param #1, #2, #5.

The settings for DOOR BELL defines by Param #3, #4, #6. Values in the range 1 to 2 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The Siren Alarm supports 3 association groups.

Group 1: Group 1

This group supports 5 nodes.

Group 2: Group 2

This group supports 5 nodes.

Group 3: Group2

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.