Flood sensor Flood/water sensor

This describes the Z-Wave device Flood sensor, manufactured by Shenzhen Neo Electronics Co., Ltd with the thing type UID of shenzhen_floodsensor_00_000.

Flood/water sensor

Inclusion Information

  1. Remove the sensor cover.

  2. Make sure the sensor is powered.

  3. Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or gateway operating manual)

  4. Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times..

Exclusion Information

  1. Remove the device cover.

  2. Make sure the sensor is powered.

  3. Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or gateway operating manual)

  4. Press the button three times within 1.5 second, the device will enter exclusion mode.

Wakeup Information

You can press the button once to wake up the device and send wakeup notification to controller.

If press successfully, the LED will blink one time.

The minimum wakeup interval is 300s

The maximum wakeup interval is 16,777,200s (about 194 days)

Allowable interval among each wakeup interval is 60 second, such as 360, 420, 480…

Note: The default value is 12 hours. This value is longer, the battery life is greater.

Channels

The following table summarises the channels available for the Flood sensor Flood/water sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the Flood sensor Flood/water sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Basic setting command Basic setting command to be transmitted
2: OFF delay The amount of delay before the OFF command is transmitted
1: Device status Sends the BASIC SET control frame when the probe detects water
2: Controller updates  

1: Basic setting command

Basic setting command to be transmitted

Overview

When the water sensor trigger alarm, it will send basic setting with these parameters. The receiver will execute this parameters. For example when the lamp receive the basic setting command, the parameters decide the brightness of the lamp.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 99
Options OFF (0)      
  Dim level (lower bound) (multilevel switch) (1)      
  Dim level (upper bound) (multilevel switch) (99)      
  ON (Binary switch) (255)      

2: OFF delay

The amount of delay before the OFF command is transmitted

Overview

Adjust the amount of delay before the OFF command is transmitted

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 1 to 65535
Default Value 30

1: Device status

Sends the BASIC SET control frame when the probe detects water

Overview

Association group 1 is assigned the status of the device - it sends the BASIC SET control frame to the associated devices when the probe has detected water.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Controller updates

Property Value
Configuration ID group_2
Data Type TEXT
Range to