Motion Sensor PIR Motion Sensor

This describes the Z-Wave device Motion Sensor, manufactured by Shenzhen Neo Electronics Co., Ltd with the thing type UID of shenzhen_motionsensor_00_000.

PIR Motion Sensor

Inclusion Information

  1. Remove the sensor cover.

  2. Make sure the sensor is powered.

  3. Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or

gateway operating manual)

  1. Press the button three times within 1.5 second, the device will enter inclusion mode. And the

LED will flash on and off alternately five times..

Exclusion Information

  1. Remove the device cover.

  2. Make sure the sensor is powered.

  3. Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or

gateway operating manual)

  1. Press the button three times within 1.5 second, the device will enter exclusion mode.

Wakeup Information

You can press the button once to wake up the device and send wakeup notification to controller.

If press successfully, the LED will blink one time.

The minimum wakeup interval is 300s

The maximum wakeup interval is 16,777,200s (about 194 days)

Allowable interval among each wakeup interval is 60 second, such as 360, 420, 480…

Note: The default value is 12 hours. This value is longer, the battery life is greater.

Channels

The following table summarises the channels available for the Motion Sensor PIR Motion Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the Motion Sensor PIR Motion Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Sensitivity Level Setting This parameter defines the sensitivity of PIR sensor. Where 8 = highest & 255 = lowest sen…
2: ON/OFF Duration Setting Determined how long the associated devices should stay ON status. This Parameter value mus…
3: Basic Set Level Basic Set Command will be sent when the door/window is opened or closed, the receiver will…
4: Enable/Disable PIR Function  
5: Lux Level Set Set a lux level value which determines when the light sensor is activated.
6: Re-trigger Interval Adjust the interval of being re-triggered after the PIR detector has been triggered. No re…
7: Light Sensor Polling Interval The Intervall after which the Light Sensor Measure is polled.
8: Lux Level Function Enable 0 = Off, 1 =On and Lux Level must be less than #5 -> then send Basic Set(Parameter #3)
9: Lux Level Changed Report How much the Lux Level must change, in lux, to be reported to the main controller.
10: LED Blink Enable Defines whether the LED blinking is on / off. 1 = enable -> blink once when motion sensor …
1: Group 1 Is assigned to the device status - OPEN/CLOSED. It enables the sensor to send reports and …
2: Group 2 Sending Control Command to associated devices. This association group is configured throug…
3: Group 3 Send Notification to associated devices.
4: Group 4 Send Notification to associated devices.

1: Sensitivity Level Setting

This parameter defines the sensitivity of PIR sensor. Where 8 = highest & 255 = lowest sensitivity

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 8 to 255
Default Value 12

2: ON/OFF Duration Setting

Determined how long the associated devices should stay ON status. This Parameter value must be large than Parameter 6#.

Overview

For instance, this parameter is set to 30(second), the PIR detector will send a

BASIC SET Command to an associated device with value basic set level if PIR

detector is triggered and the associated device will be turned on 30(second) before it

is turned off.

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 5 to 600
Default Value 30

3: Basic Set Level

Basic Set Command will be sent when the door/window is opened or closed, the receiver will take it for consideration; for instance, if a lamp module received the BSC of which value is decisive as to how bright of dim level of lamp module shall be.

Overview

Available Settings:

 0 - Off, Alarm cancelling or turning a device OFF

1~99 or 255 – ON (Binary Switch Device)

                      Dim Level (Multilevel Switch Device)

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 255
Default Value 255

4: Enable/Disable PIR Function

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 255
Options Disable PIR Detector Function (0)      
  Enable PIR Detector Function (255)      

5: Lux Level Set

Set a lux level value which determines when the light sensor is activated.

Overview

If the ambient illumination level falls below this value and a person moves

across or within the detected area , PIR detector will send a Z-Wave ON

command(i.e. BASIC_SET value = parameter 3#) to an associated device and activate

it.

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 1000
Default Value 100

6: Re-trigger Interval

Adjust the interval of being re-triggered after the PIR detector has been triggered. No report will be sent during this interval if a movement is presented. This Parameter value must be less than Parameter 2#.

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 1 to 8
Default Value 8

7: Light Sensor Polling Interval

The Intervall after which the Light Sensor Measure is polled.

Property Value
Configuration ID config_7_2
Data Type INTEGER
Range 60 to 36000
Default Value 180

8: Lux Level Function Enable

0 = Off, 1 =On and Lux Level must be less than #5 -> then send Basic Set(Parameter #3)

Overview

If this parameter is set to ‘1’, and when Lux level less than the value define by parameter #5, PIR

detector will send a BASIC_SET command frame(i.e. BASIC_SET (value = parameter 3) to an

associated device and activate it. If Lux Level greater than the value define by parameter #5, PIR

detector will not send a BASIC_SET command frame.

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options Disable Lux Level Function (0)      
  Enable Lux Level Function (1)      

9: Lux Level Changed Report

How much the Lux Level must change, in lux, to be reported to the main controller.

Property Value
Configuration ID config_9_2
Data Type INTEGER
Range 0 to 255
Default Value 100

Defines whether the LED blinking is on / off. 1 = enable -> blink once when motion sensor detect movement, 0= disbale

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 1
Options Disable LED blinking (0)      
  Enable LED blinking (1)      

1: Group 1

Is assigned to the device status - OPEN/CLOSED. It enables the sensor to send reports and readings to Z-Wave Controller or Z-Wave Gateway whenever the sensor is triggered.

Overview

NOTIFICATION_REPORT

COMMAND_CLASS_SENSOR_BINARY_V2

COMMAND_CLASS_SENSOR_MULTILEVEL_V7

BATTERY_REPORT

DEVICE_RESET_LOCALLY_NOTIFICATION

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Sending Control Command to associated devices. This association group is configured through the advanced parameters no. 2, 3, 5 and 8

Overview

BASIC_SET

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Send Notification to associated devices.

Overview

NOTIFICATION_REPORT_V4

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Group 4

Send Notification to associated devices.

Overview

SENSOR_BINARY_REPORT_V2

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.