NAS-DS01Z Cyrus Door Window Sensor

This describes the Z-Wave device NAS-DS01Z, manufactured by Shenzhen Neo Electronics Co., Ltd with the thing type UID of shenzhen_nasds01z_00_000.

Cyrus Door Window Sensor

Channels

The following table summarises the channels available for the NAS-DS01Z Cyrus Door Window Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm (access) alarm_access alarm_access Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the NAS-DS01Z Cyrus Door Window Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: OFF Delay Adjust the amount of delay before the OFF command is transmitted.
2: Basic Set Level  
1: Lifeline GROUP 1 is lifeline service that assigned to Sensor (Door/Window detector) status – Open/C…
2: Group 2 GROUP 2 allows for sending control commands to associated devices such as relay module, li…
3: Group 3 GROUP 3 allows for Send Notification to associated devices in this group. This Group Suppo…
4: Group 4 GROUP 4 allows for Send Notification to associated devices in this group. This Group Suppo…

1: OFF Delay

Adjust the amount of delay before the OFF command is transmitted.

Overview

Description This configuration parameter that can be used to adjust the amount of delay before the OFF command is transmitted. This parameter can be configured with the value of 0 through 65535, where 0 means send OFF command immediately and 65535 means 65535 seconds of delay.

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

2: Basic Set Level

Property Value      
Configuration ID config_2_1      
Data Type INTEGER      
Range -1 to 99   Default Value -1
Options ON (Binary Switch Device) (-1)      
  OFF, Alarm cancelling or turning a device off (0)      

1: Lifeline

GROUP 1 is lifeline service that assigned to Sensor (Door/Window detector) status – Open/Close

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

GROUP 2 allows for sending control commands to associated devices such as relay module, lighting, etc. This association group is configured through the advanced parameters no. 1 and 2. This Group Support: BASIC_SET.

Overview

GROUP 2 allows for sending control commands to associated devices such as relay module, lighting, etc. This association group is configured through the advanced parameters no. 1 and 2. This Group Support: BASIC_SET.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

GROUP 3 allows for Send Notification to associated devices in this group. This Group Support: NOTIFICATION_REPORT.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Group 4

GROUP 4 allows for Send Notification to associated devices in this group. This Group Support: SENSOR_BINARY_REPORT

Overview

GROUP 4 allows for Send Notification to associated devices in this group. This Group Support: SENSOR_BINARY_REPORT

Property Value
Configuration ID group_4
Data Type TEXT
Range to