TZDW-100 Door/window sensor

This describes the Z-Wave device TZDW-100, manufactured by Telldus Technologies AB with the thing type UID of telldus_tzdw100_00_000.

Door/window sensor

Channels

The following table summarises the channels available for the TZDW-100 Door/window sensor.

Channel Channel Id Channel Type UID Category Item Type
Door Sensor sensor_door sensor_door Door Contact
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the TZDW-100 Door/window sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Select what type of command to be sent to nodes in association group 2
2: Select what value that should be sent to association group 2
3: Type of commands to association group 2
4: Select what type of command to be sent to nodes in association group 3
5: Select what value that should be sent to association group 3
6: Type of commands to association group 3
7: LED-Indicator
8: Select the type of command to be sent in the Lifeline
1: Lifeline Lifeline - Sensor status
2: Status Sensor status
3: Status Sensor status

1:

Select what type of command to be sent to nodes in association group 2

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Basic (0)      
  Switch Binary (1)      
  Switch All (2)      
  Switch Multilevel (3)      

2:

Select what value that should be sent to association group 2

Property Value      
Configuration ID config_2_1      
Data Type INTEGER      
Range 0 to 63   Default Value 255
Options Last value (255)      

3:

Type of commands to association group 2

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Normal (0)      
  Inverted (1)      

4:

Select what type of command to be sent to nodes in association group 3

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options Basic (0)      
  Switch Binary (1)      
  Switch All (2)      
  Switch Multilevel (3)      

5:

Select what value that should be sent to association group 3

Property Value      
Configuration ID config_5_1      
Data Type INTEGER      
Range 0 to 63   Default Value 255
Options Last value (255)      

6:

Type of commands to association group 3

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options Normal (0)      
  Inverted (1)      

7:

LED-Indicator

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options Off (0)      
  On (1)      

8:

Select the type of command to be sent in the Lifeline

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options Notification (0)      
  Sensor binary (1)      

1: Lifeline

Lifeline - Sensor status

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Status

Sensor status

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Status

Sensor status

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.